Comparison of chemistry analytes between 2 portable, commercially available analyzers and a conventional laboratory analyzer in reptiles

被引:25
|
作者
McCain, Stephanie L. [2 ]
Flatland, Bente [1 ]
Schumacher, Juergen P. [2 ]
Clarke, Elsburgh O., III [2 ,3 ]
Fry, Michael M. [1 ]
机构
[1] Univ Tennessee, Coll Vet Med, Dept Pathobiol, Knoxville, TN 37996 USA
[2] Univ Tennessee, Coll Vet Med, Dept Small Anim Clin Sci, Knoxville, TN 37996 USA
[3] N Carolina State Univ, Coll Vet Med, Dept Clin Sci, Raleigh, NC USA
关键词
Clinical chemistry; i-STAT; method comparison; point-of-care; reptile; VetScan; CLINICAL ANALYZER;
D O I
10.1111/j.1939-165X.2010.00258.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background Advantages of handheld and small bench-top biochemical analyzers include requirements for smaller sample volume and practicality for use in the field or in practices, but little has been published on the performance of these instruments compared with standard reference methods in analysis of reptilian blood. Objective The aim of this study was to compare reptilian blood biochemical values obtained using the Abaxis VetScan Classic bench-top analyzer and a Heska i-STAT handheld analyzer with values obtained using a Roche Hitachi 911 chemical analyzer. Methods Reptiles, including 14 bearded dragons (Pogona vitticeps), 4 blue-tongued skinks (Tiliqua gigas), 8 Burmese star tortoises (Geochelone platynota), 10 Indian star tortoises (Geochelone elegans), 5 red-tailed boas (Boa constrictor), and 5 Northern pine snakes (Pituophis melanoleucus melanoleucus), were manually restrained, and a single blood sample was obtained and divided for analysis. Results for concentrations of albumin, bile acids, calcium, glucose, phosphates, potassium, sodium, total protein, and uric acid and activities of aspartate aminotransferase and creatine kinase obtained from the VetScan Classic and Hitachi 911 were compared. Results for concentrations of chloride, glucose, potassium, and sodium obtained from the i-STAT and Hitachi 911 were compared. Results Compared with results from the Hitachi 911, those from the VetScan Classic and i-STAT had variable correlations, and constant or proportional bias was found for many analytes. Bile acid data could not be evaluated because results for 44 of 45 samples fell below the lower linearity limit of the VetScan Classic. Conclusions Although the 2 portable instruments might provide measurements with clinical utility, there were significant differences compared with the reference analyzer, and development of analyzer-specific reference intervals is recommended.
引用
收藏
页码:474 / 479
页数:6
相关论文
共 17 条
  • [11] Short term Caco-2/TC7 cell culture: Comparison between of conventional 21-d and a commercially available 3-d system
    Da Violante, G
    Zerrouk, N
    Richard, I
    Frendo, JL
    Zhiri, A
    Li-Khuan, R
    Tricottet, V
    Provot, G
    Chaumeil, JC
    Arnaud, P
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2004, 27 (12) : 1986 - 1992
  • [12] COMPARISON BETWEEN RESEARCH-GRADE AND COMMERCIALLY AVAILABLE SnO2 FOR THIN-FILM CdTe SOLAR CELLS
    Li, Xiaonan
    Pankow, Joel
    To, Bobby
    Gessert, Timothy
    PVSC: 2008 33RD IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE, VOLS 1-4, 2008, : 289 - 293
  • [13] BIOCHEMICAL AND CLINICAL COMPARISON OF 2 COMMERCIALLY AVAILABLE CREATINE-KINASE ISO-ENZYME MB-ASSAY KITS SUITABLE FOR USE IN THE ROUTINE MEDICAL LABORATORY
    SURTEES, SJ
    BASTABLE, MD
    GIETZEN, TW
    MODEL, DG
    CARMICHAEL, DJS
    BORDOLI, G
    KIDNER, PH
    ANNALS OF CLINICAL BIOCHEMISTRY, 1979, 16 (JUL) : 197 - 204
  • [14] Comparison of commercially available 25OHD and 1,25(OH)2D assays: Experience of pediatric hospital laboratory participating in DEQAS proficiency testing
    Czekuc-Kryskiewicz, E.
    Wojcik, M.
    Parafiniuk, B.
    Skorupa, E.
    Pludowski, P.
    CLINICA CHIMICA ACTA, 2019, 493 : S652 - S653
  • [15] Research Note: Comparison of chicken blood chemistry and electrolyte parameters between the portable i-STAT1 clinical analyzer and VetScan VS2 serum biochemistry panel using Hy-Line commercial white-egg laying hens
    Sauer, Z. C.
    Taylor, K.
    Wolc, A.
    Viall, A.
    Fulton, J. E.
    Settar, P.
    Rubinoff, I
    Schaal, T.
    Sato, Y.
    POULTRY SCIENCE, 2020, 99 (07) : 3487 - 3490
  • [16] On the structure of 3-acetylamino-5-methyl-1,2,4-oxadiazole and on the fully degenerate rearrangements (FDR) of its anion: a stimulating comparison between the results of 'in-silicon chemistry' and 'laboratory chemistry'
    Mugnoli, Angelo
    Barone, Giampaolo
    Buscemi, Silvestre
    Lanza, Camilla Zaira
    Pace, Andrea
    Pani, Marcella
    Spinelli, Domenico
    JOURNAL OF PHYSICAL ORGANIC CHEMISTRY, 2009, 22 (11) : 1086 - 1093
  • [17] Comparison of automated determination of total bilirubin in laboratory animals using Roche Diagnostic total bilirubin 2,5-Dichlorophe-nyldiazonium Tetrafluoroborate(DPD) and Diagnostic Chemicals Limited total bilirubin-SL 2,4 Dichlorophenyl diazonium salt with the Bayer ADVIA® 1650 Chemistry Analyzer.
    Sansone, J
    Taggart, PW
    Coady, HC
    CLINICAL CHEMISTRY, 2003, 49 (06) : A155 - A156