Novel Algorithm for Radon Real-Time Measurements with a Pixelated Detector

被引:2
|
作者
Rizzo, Alessandro [1 ]
Cardellini, Francesco [2 ]
Poggi, Claudio [3 ]
Borra, Enrico [1 ]
Ciciani, Luca [1 ]
Narici, Livio [4 ]
Sperandio, Luciano [1 ]
Vilardi, Ignazio [1 ]
机构
[1] Italian Natl Agcy New Technol Energy & Sustainabl, Radiat Protect Inst IRP, Via Anguillarese 301, I-00123 Rome, Italy
[2] Italian Natl Agcy New Technol Energy & Sustainabl, Natl Inst Ionizing Radiat Metrol INMRI, Via Anguillarese 301, I-00123 Rome, Italy
[3] Italian Natl Agcy New Technol Energy & Sustainabl, Radiat Protect Inst IRP, Via Enrico Fermi 45, I-00044 Rome, Italy
[4] Univ Roma Tor Vergata, Phys Dept, Via Ric Sci 1, I-00133 Rome, Italy
关键词
radon; real-time measurements; TimePix; MediPix; pattern recognition algorithm; LUCAS CELL; INDOOR; AIR;
D O I
10.3390/s22020516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, radon gas exposure is considered one of the main health concerns for the population because, by carrying about half the total dose due to environmental radioactivity, it is the second cause of lung cancer after smoking. Due to a relatively long half-life of 3.82 days, the chemical inertia and since its parent Ra-226 is largely diffuse on the earth's crust and especially in the building materials, radon can diffuse and potentially saturate human habitats, with a concentration that can suddenly change during the 24 h day depending on temperature, pressure, and relative humidity. For such reasons, 'real-time' measurements performed by an active detector, possibly of small dimensions and a handy configuration, can play an important role in evaluating the risk and taking the appropriate countermeasures to mitigate it. In this work, a novel algorithm for pattern recognition was developed to exploit the potentialities of silicon active detectors with a pixel matrix structure to measure radon through the alpha emission, in a simple measurement configuration, where the device is placed directly in air with no holder, no collection filter or electrostatic field to drift the radon progenies towards the detector active area. This particular measurement configuration (dubbed as bare) requires an alpha/beta-discrimination method that is not based on spectroscopic analysis: as the gas surrounds the detector the alpha particles are emitted at different distances from it, so they lose variable energy amount in air depending on the traveled path-length which implies a variable deposited energy in the active area. The pixels matrix structure allows overcoming this issue because the interaction of alpha, beta and gamma particles generate in the active area of the detector clusters (group of pixels where a signal is read) of different shape and energy dispersion. The novel algorithm that exploits such a phenomenon was developed using a pixelated silicon detector of the TimePix family with a compact design. An alpha (Am-241) and a beta (Sr-90) source were used to calibrate the algorithm and to evaluate its performances in terms of beta rejection capability and alpha recognition efficiency. Successively, the detector was exposed to different radon concentrations at the ENEA-INMRI radon facility in 'bare' configuration, in order to check the linearity of the device response over a radon concentration range. The results for this technique are presented and discussed, highlighting the potential applications especially the possibility to exploit small and handy detectors to perform radon active measurements in the simplest configuration.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] A local real-time bar detector based on the multiscale Radon transform
    Oliva-Garcia, Ricardo
    Gomez-Cardenes, Oscar
    Marichal-Hernandez, Jose G.
    Martin-Hernandez, Javier
    Phillip-Luke, Jonas
    Rodriguez-Ramos, Jose M.
    REAL-TIME IMAGE PROCESSING AND DEEP LEARNING 2022, 2022, 12102
  • [2] A real-time edge detector: Algorithm and VLSI architecture
    Alzahrani, FM
    Chen, T
    REAL-TIME IMAGING, 1997, 3 (05) : 363 - 378
  • [3] REAL-TIME ALGORITHM FOR A PORTABLE CARDIAC-ARRHYTHMIA DETECTOR
    HUNGENAHALLY, SK
    GANDER, RE
    CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY CONFERENCE : PROCEEDINGS - 1989, 1989, : 9 - 10
  • [4] A novel real-time superpixel segmentation algorithm
    Zhu, Song
    Cao, Danhua
    Wu, Yubin
    Jiang, Shixiong
    2013 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC IMAGING AND PROCESSING TECHNOLOGY, 2013, 9045
  • [5] Development of a real-time radon monitoring system for simultaneous measurements in multiple sites
    Yamamoto, S.
    Yamasoto, K.
    Iida, T.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1052 - 1055
  • [6] Development of a real-time radon monitoring system for simultaneous measurements in multiple sites
    Yamamoto, S
    Yamasoto, K
    Iida, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 1929 - 1933
  • [7] A real-time novelty detector for artefact identification in physiological measurements.
    Beatty, PCW
    Hoare, SW
    Asbridge, D
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 616 - 618
  • [8] A Real-Time Deformable Detector
    Ali, Karim
    Fleuret, Francois
    Hasler, David
    Fua, Pascal
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2012, 34 (02) : 225 - 239
  • [9] A real-time face detector
    Zhang, SC
    Liu, ZQ
    2004 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN & CYBERNETICS, VOLS 1-7, 2004, : 2197 - 2202
  • [10] A novel adaptive real-time detection algorithm for an area-efficient CMOS spike detector circuit
    Dwivedi, Shashank
    Gogoi, Anup K.
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 2018, 88 : 87 - 97