Novel Algorithm for Radon Real-Time Measurements with a Pixelated Detector

被引:2
|
作者
Rizzo, Alessandro [1 ]
Cardellini, Francesco [2 ]
Poggi, Claudio [3 ]
Borra, Enrico [1 ]
Ciciani, Luca [1 ]
Narici, Livio [4 ]
Sperandio, Luciano [1 ]
Vilardi, Ignazio [1 ]
机构
[1] Italian Natl Agcy New Technol Energy & Sustainabl, Radiat Protect Inst IRP, Via Anguillarese 301, I-00123 Rome, Italy
[2] Italian Natl Agcy New Technol Energy & Sustainabl, Natl Inst Ionizing Radiat Metrol INMRI, Via Anguillarese 301, I-00123 Rome, Italy
[3] Italian Natl Agcy New Technol Energy & Sustainabl, Radiat Protect Inst IRP, Via Enrico Fermi 45, I-00044 Rome, Italy
[4] Univ Roma Tor Vergata, Phys Dept, Via Ric Sci 1, I-00133 Rome, Italy
关键词
radon; real-time measurements; TimePix; MediPix; pattern recognition algorithm; LUCAS CELL; INDOOR; AIR;
D O I
10.3390/s22020516
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nowadays, radon gas exposure is considered one of the main health concerns for the population because, by carrying about half the total dose due to environmental radioactivity, it is the second cause of lung cancer after smoking. Due to a relatively long half-life of 3.82 days, the chemical inertia and since its parent Ra-226 is largely diffuse on the earth's crust and especially in the building materials, radon can diffuse and potentially saturate human habitats, with a concentration that can suddenly change during the 24 h day depending on temperature, pressure, and relative humidity. For such reasons, 'real-time' measurements performed by an active detector, possibly of small dimensions and a handy configuration, can play an important role in evaluating the risk and taking the appropriate countermeasures to mitigate it. In this work, a novel algorithm for pattern recognition was developed to exploit the potentialities of silicon active detectors with a pixel matrix structure to measure radon through the alpha emission, in a simple measurement configuration, where the device is placed directly in air with no holder, no collection filter or electrostatic field to drift the radon progenies towards the detector active area. This particular measurement configuration (dubbed as bare) requires an alpha/beta-discrimination method that is not based on spectroscopic analysis: as the gas surrounds the detector the alpha particles are emitted at different distances from it, so they lose variable energy amount in air depending on the traveled path-length which implies a variable deposited energy in the active area. The pixels matrix structure allows overcoming this issue because the interaction of alpha, beta and gamma particles generate in the active area of the detector clusters (group of pixels where a signal is read) of different shape and energy dispersion. The novel algorithm that exploits such a phenomenon was developed using a pixelated silicon detector of the TimePix family with a compact design. An alpha (Am-241) and a beta (Sr-90) source were used to calibrate the algorithm and to evaluate its performances in terms of beta rejection capability and alpha recognition efficiency. Successively, the detector was exposed to different radon concentrations at the ENEA-INMRI radon facility in 'bare' configuration, in order to check the linearity of the device response over a radon concentration range. The results for this technique are presented and discussed, highlighting the potential applications especially the possibility to exploit small and handy detectors to perform radon active measurements in the simplest configuration.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Novel real-time alignment and calibration of the LHCb detector and its performance
    Borghi, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 560 - 564
  • [22] REAL-TIME HARMONIC PITCH DETECTOR
    SENEFF, S
    IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1978, 26 (04): : 358 - 365
  • [23] REAL-TIME HARMONIC PITCH DETECTOR
    SENEFF, S
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1976, 60 : S107 - S107
  • [24] REAL-TIME CORRELATOR WITH A PEAK DETECTOR
    TAI, I
    HASEGAWA, KI
    SEKIGUCHI, A
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1975, 8 (03): : 206 - 208
  • [25] REAL-TIME NUMERICAL PEAK DETECTOR
    BLAIS, F
    RIOUX, M
    SIGNAL PROCESSING, 1986, 11 (02) : 145 - 155
  • [26] Real-time detector of GSM terminals
    Vales-Alonso, J
    de Vicente, FI
    González-Castaño, FJ
    Pousada-Carballo, JM
    IEEE COMMUNICATIONS LETTERS, 2001, 5 (06) : 275 - 276
  • [27] REAL-TIME PROCESSING OF DETECTOR DATA
    SIPPACH, W
    BENENSON, G
    KNAPP, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 578 - 581
  • [28] A robust, real-time ellipse detector
    Zhang, SC
    Liu, ZQ
    PATTERN RECOGNITION, 2005, 38 (02) : 273 - 287
  • [29] Real-time full Stokes quantitative imaging with a pixelated polarization camera
    Chen, Kaiquan
    Vinu, R. V.
    Liao, Dongyang
    Tang, Miaomiao
    Chen, Ziyang
    Pu, Jixiong
    JOURNAL OF OPTICS, 2024, 26 (10)
  • [30] A novel sparse representation algorithm for AIS real-time signals
    Shuaiheng Huai
    Shufang Zhang
    EURASIP Journal on Wireless Communications and Networking, 2018