Data filtering in the readout of the CMS Electromagnetic Calorimeter

被引:0
|
作者
Almeida, N. [1 ]
Silva, P. [1 ]
Da Silva, J. C. [1 ]
Husejko, M. [1 ]
Jain, A. [1 ]
Musella, P. [1 ]
Mendes, A. [1 ]
Gallinaro, M. [1 ]
Varela, J. [1 ]
Faure, J. -L. [2 ]
Gras, P. [2 ]
Mandjavidze, L. [2 ]
Busson, P. [3 ]
Paganini, P. [3 ]
机构
[1] LIP, Lisbon, Portugal
[2] CEA Saclay, DAPNIA, Saclay, France
[3] Ecole Polytech, CNRS, IN2P3, LLR, F-91128 Palaiseau, France
关键词
data acquisition; data filtering; CMS; LHC; trigger system; selective readout; trigger systems;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For an efficient data talking, the Electromagnetic Calorimeter (ECAL) data of the CMS experiment must be limited to 10% of the full event size (INS). Other requirements limit the average data size to 2kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the ECAL detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor.
引用
收藏
页码:571 / +
页数:2
相关论文
共 50 条
  • [1] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. L.
    Gras, P.
    Mandjavidze, I.
    Busson, P.
    Paganini, P.
    [J]. JOURNAL OF INSTRUMENTATION, 2008, 3 (02)
  • [2] The CMS electromagnetic calorimeter readout
    Martin, F
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 192 - 196
  • [3] Overview of the readout of the CMS electromagnetic calorimeter
    Ille, B
    [J]. PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 439 - 450
  • [4] Selective readout in the CMS electromagnetic calorimeter
    Monteiro, T
    [J]. PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 247 - 250
  • [5] Design of a Data Concentrator card for the CMS Electromagnetic Calorimeter Readout
    Silva, JC
    Almeida, N
    Antonio, V
    Correia, A
    Machado, P
    Teixeira, I
    Varela, J
    [J]. PROCEEDINGS OF THE SEVENTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2001, 2001 (05): : 331 - 333
  • [6] The MGPA electromagnetic calorimeter readout chip for CMS
    Raymond, M
    Crooks, J
    French, M
    Hall, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) : 756 - 763
  • [7] The digital readout system for the CMS electromagnetic calorimeter
    Lofstedt, B
    [J]. PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 251 - 254
  • [8] The MGPA electromagnetic calorimeter readout chip for CMS
    Raymond, M
    Crooks, J
    French, M
    Hall, G
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 156 - 160
  • [9] The digital readout system for the CMS electromagnetic calorimeter
    Lofstedt, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 433 - 439
  • [10] The LiTE-DTU: A Data Conversion and Compression ASIC for the Readout of the CMS Electromagnetic Calorimeter
    Mazza, Giovanni
    Argiro, Stefano
    Borca, Cecilia
    Cometti, Simona
    Cossio, Fabio
    Dejardin, Marc
    Dellacasa, Giulio
    Mignone, Marco
    Pastrone, Nadia
    Soldi, Dario
    Silvestrin, Luca
    Tedesco, Silvia
    Tessaro, Mario
    Varela, Joao
    Wheadon, Richard
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (06) : 1215 - 1222