The MGPA electromagnetic calorimeter readout chip for CMS

被引:7
|
作者
Raymond, M [1 ]
Crooks, J
French, M
Hall, G
机构
[1] Univ London Imperial Coll Sci Technol & Med, Blackett Lab, High Energy Phys Grp, London SW7 2BW, England
[2] Rutherford Appleton Lab, Microelect Grp, Didcot OX11 0QX, Oxon, England
关键词
calorimetry; CMOS analog integrated circuits; radiation detectors;
D O I
10.1109/TNS.2005.850979
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The multiple-gain preamplifier (MGPA) is a three-gain channel 0.25 mu m CMOS chip matched to the noise and linearity requirements of the electromagnetic calorimeter for the Compact Muon Solenoid (CMS) experiment. A choice of external feedback components to the first-stage amplifier allows the chip to match the different full-scale signal and noise requirements for both barrel and end-cap regions of the detector. For the barrel (end-cap) application the noise is less than 10 000 (3,500) electrons at a peaking time of 40 ns and an integral nonlinearity of approximately +/- 0.1% full-scale is achieved for all three gain ranges. Details of the design and performance are presented, including measurements of nonlinearity, pulse-shape matching, noise, and radiation tolerance.
引用
收藏
页码:756 / 763
页数:8
相关论文
共 50 条
  • [1] The MGPA electromagnetic calorimeter readout chip for CMS
    Raymond, M
    Crooks, J
    French, M
    Hall, G
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 156 - 160
  • [2] The CMS electromagnetic calorimeter readout
    Martin, F
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 192 - 196
  • [3] Overview of the readout of the CMS electromagnetic calorimeter
    Ille, B
    [J]. PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 439 - 450
  • [4] Selective readout in the CMS electromagnetic calorimeter
    Monteiro, T
    [J]. PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 247 - 250
  • [5] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. -L.
    Gras, P.
    Mandjavidze, L.
    Busson, P.
    Paganini, P.
    [J]. 2007 15TH IEEE-NPSS REAL-TIME CONFERENCE, VOLS 1 AND 2, 2007, : 571 - +
  • [6] The digital readout system for the CMS electromagnetic calorimeter
    Lofstedt, B
    [J]. PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 251 - 254
  • [7] Data filtering in the readout of the CMS Electromagnetic Calorimeter
    Almeida, N.
    Silva, P.
    Da Silva, J. C.
    Husejko, M.
    Jain, A.
    Musella, P.
    Mendes, A.
    Gallinaro, M.
    Varela, J.
    Faure, J. L.
    Gras, P.
    Mandjavidze, I.
    Busson, P.
    Paganini, P.
    [J]. JOURNAL OF INSTRUMENTATION, 2008, 3 (02)
  • [8] The digital readout system for the CMS electromagnetic calorimeter
    Lofstedt, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2): : 433 - 439
  • [9] Design of a Data Concentrator card for the CMS Electromagnetic Calorimeter Readout
    Silva, JC
    Almeida, N
    Antonio, V
    Correia, A
    Machado, P
    Teixeira, I
    Varela, J
    [J]. PROCEEDINGS OF THE SEVENTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2001, 2001 (05): : 331 - 333
  • [10] Light-to-light readout system of the CMS electromagnetic calorimeter
    Denes, P
    Bussat, JM
    Lustermann, W
    Mathez, H
    Pangaud, P
    Walder, JP
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 499 - 503