Data filtering in the readout of the CMS Electromagnetic Calorimeter

被引:0
|
作者
Almeida, N. [1 ]
Silva, P. [1 ]
Da Silva, J. C. [1 ]
Husejko, M. [1 ]
Jain, A. [1 ]
Musella, P. [1 ]
Mendes, A. [1 ]
Gallinaro, M. [1 ]
Varela, J. [1 ]
Faure, J. -L. [2 ]
Gras, P. [2 ]
Mandjavidze, L. [2 ]
Busson, P. [3 ]
Paganini, P. [3 ]
机构
[1] LIP, Lisbon, Portugal
[2] CEA Saclay, DAPNIA, Saclay, France
[3] Ecole Polytech, CNRS, IN2P3, LLR, F-91128 Palaiseau, France
关键词
data acquisition; data filtering; CMS; LHC; trigger system; selective readout; trigger systems;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For an efficient data talking, the Electromagnetic Calorimeter (ECAL) data of the CMS experiment must be limited to 10% of the full event size (INS). Other requirements limit the average data size to 2kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the ECAL detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor.
引用
收藏
页码:571 / +
页数:2
相关论文
共 50 条
  • [31] Calibration of the CMS electromagnetic calorimeter with LHC collision data
    Obertino, M. M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 99 - 101
  • [32] Calibration of the CMS Electromagnetic Calorimeter with first LHC data
    Sola, V.
    COSMIC RAYS FOR PARTICLE AND ASTROPARTICLE PHYSICS, 2011, 6 : 52 - 57
  • [33] PERFORMANCE OF THE CMS ELECTROMAGNETIC CALORIMETER
    Pastrone, N.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 354 - 358
  • [34] The Electromagnetic Calorimeter of the CMS Experiment
    Pastrone, Nadia
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1964 - 1970
  • [35] The CMS electromagnetic calorimeter at the LHC
    Ryan, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (01): : 217 - 219
  • [36] Overview of the CMS electromagnetic calorimeter
    Ernenwein, JP
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 186 - 191
  • [37] Calibration of the CMS electromagnetic calorimeter
    Paramatti, R
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 232 - 236
  • [38] The CMS Electromagnetic Calorimeter workflow
    Rovelli, Chiara
    24TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2019), 2020, 245
  • [39] The CMS electromagnetic calorimeter simulation
    Cossutti, Fabio
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1465 - 1469
  • [40] Calibration of the electromagnetic calorimeter of CMS
    Massironi, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2010, 33 (06):