Insulation problems in medium-voltage stator coils under fast repetitive voltage pulses

被引:40
|
作者
Haq, Saeed Ul [1 ]
Jayaram, Shesha H. [1 ]
Cherney, Edward A. [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
adjustable-speed drives; converters; dielectric heating; groundwall insulation; induction motor; partial discharge (PD); pulse voltage; solid-state switches;
D O I
10.1109/TIA.2008.926305
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the degradation processes in stator-bar groundwall insulation that is subjected to steep-front voltage pulses, at different temperatures, are studied. The test conditions include pulse voltage amplitudes up to 6 kV(p) and pulse switching frequencies up to 3 kHz in ambient temperatures of 23 degrees C, 120 degrees C, and 155 degrees C. During the aging process, the surface temperature is monitored with an infrared camera to determine the regions with highest temperatures and the partial discharge (PD) activity. The visual examination of failed bars confirmed that the groundwall insulation in these regions is degraded.
引用
收藏
页码:1004 / 1012
页数:9
相关论文
共 50 条
  • [41] Detection of Artificial Insulation Defects in a Medium-Voltage Motor by Dielectric Spectroscopy Analysis
    Obame, E.
    Rain, P.
    Gallot-Lavallee, O.
    Tripot, G.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) : 270 - 276
  • [42] Effect of the density and the position of the microvoids on the electrical constraints in the insulation of medium-voltage cables
    Medoukali, H.
    Zegnini, B.
    PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020), 2020, : 521 - 524
  • [43] The idea of system control and monitoring of a complete medium-voltage switchgear with solid insulation
    Shul’ga R.N.
    Shul’ga A.R.
    Kovalev D.I.
    Khrenov S.I.
    Koshelev M.A.
    Russian Electrical Engineering, 2017, 88 (8) : 509 - 514
  • [44] Investigation of the failure mechanism of insulation subjected to repetitive fast voltage surges
    Foulon, N
    Lucas, JP
    Barre, G
    Mailfert, R
    Enon, J
    PROCEEDINGS: ELECTRICAL INSULATION CONFERENCE AND ELECTRICAL MANUFACTURING & COIL WINDING CONFERENCE, 1997, : 401 - 406
  • [45] Comparison of the effects of short, high-voltage and long, medium-voltage pulses on skin electrical and transport properties
    Vanbever, R
    Pliquett, UF
    Préat, V
    Weaver, JC
    JOURNAL OF CONTROLLED RELEASE, 1999, 60 (01) : 35 - 47
  • [46] Effects of converter pulses on the electrical insulation in low and medium voltage motors
    Wheeler, JCG
    IEEE ELECTRICAL INSULATION MAGAZINE, 2005, 21 (02) : 22 - 29
  • [47] CASE STUDIES OF STATOR WINDING TURN INSULATION FAILURES IN MEDIUM VOLTAGE MOTORS
    Lee, Sang Bin
    Kang, Tae-June
    Kim, Heedong
    Kong, Taesik
    Lim, Chaewoong
    IEEE CONFERENCE RECORD OF 2017 ANNUAL PULP, PAPER AND FOREST INDUSTRIES TECHNICAL CONFERENCE (PPFIC), 2017,
  • [48] Flexible Medium Voltage Stator Coil Insulation System for On-site Winding
    Ul Haq, Saeed
    Omranipour, Ramtin
    Hanna, George
    Lucas, William
    Znidarich, Michael
    CONFERENCE RECORD OF THE 2012 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2012, : 291 - 295
  • [49] Optimized Dielectric Design of Stator Windings from Medium Voltage Induction Machines Fed by Fast Front Pulses
    Hussain, Mohammed Khalil
    Gomez, Pablo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (02) : 837 - 846
  • [50] Synchronous optimal pulsewidth modulation and stator flux trajectory control for medium-voltage drives
    Holtz, Joachim
    Oikonomou, Nikolaos
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (02) : 600 - 608