Insulation problems in medium-voltage stator coils under fast repetitive voltage pulses

被引:40
|
作者
Haq, Saeed Ul [1 ]
Jayaram, Shesha H. [1 ]
Cherney, Edward A. [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
adjustable-speed drives; converters; dielectric heating; groundwall insulation; induction motor; partial discharge (PD); pulse voltage; solid-state switches;
D O I
10.1109/TIA.2008.926305
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, the degradation processes in stator-bar groundwall insulation that is subjected to steep-front voltage pulses, at different temperatures, are studied. The test conditions include pulse voltage amplitudes up to 6 kV(p) and pulse switching frequencies up to 3 kHz in ambient temperatures of 23 degrees C, 120 degrees C, and 155 degrees C. During the aging process, the surface temperature is monitored with an infrared camera to determine the regions with highest temperatures and the partial discharge (PD) activity. The visual examination of failed bars confirmed that the groundwall insulation in these regions is degraded.
引用
收藏
页码:1004 / 1012
页数:9
相关论文
共 50 条
  • [21] Partial Discharge Finite Element Analysis under Fast, Repetitive Voltage Pulses
    Borghei, Moein
    Ghassemi, Mona
    2019 IEEE ELECTRIC SHIP TECHNOLOGIES SYMPOSIUM (ESTS 2019): EMERGING TECHNOLOGIES FOR FUTURE ELECTRIC SHIPS, 2019, : 324 - 328
  • [22] Progress on iec 60034-18-42 for qualification of stator insulation for medium-voltage inverter duty applications
    Stranges, M. K. W.
    Stone, G. C.
    Bogh, D. L.
    INDUSTRY APPLICATIONS SOCIETY 54TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 2007, : 57 - +
  • [23] A Coupled Electro-thermal Study of the Stress Grading System of Medium Voltage Motor Coils when Energized by Repetitive Fast Pulses
    Sharifi, E.
    Jayaram, S.
    Cherney, E. A.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,
  • [24] MEDIUM-VOLTAGE DRIVES
    Hiller, Marc
    Sommer, Rainer
    Beuermann, Max
    IEEE INDUSTRY APPLICATIONS MAGAZINE, 2010, 16 (02) : 22 - 30
  • [25] High-Voltage High-Frequency Testing for Medium-Voltage Motor Insulation Degradation
    Mirza, Arshiah
    Chen, Weiqiang
    Hiep Nguyen
    Cao, Yang
    Bazzi, Ali M.
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 2444 - 2447
  • [26] Use of an optimization algorithm in designing medium-voltage switchgear insulation elements
    Kitak, P
    Pihler, J
    Ticar, I
    Stermecki, A
    Magele, C
    Bíró, O
    Preis, K
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (04) : 1347 - 1350
  • [27] Operation of a medium-voltage drive under faulty conditions
    Rodríguez, J
    Pontt, J
    Musalem, R
    Hammond, P
    IPEMC 2004: THE 4TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2004, : 799 - 803
  • [28] Operation of a medium-voltage drive under faulty conditions
    Rodríguez, J
    Hammond, PW
    Pontt, J
    Musalem, R
    Lezana, P
    Escobar, MJ
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (04) : 1080 - 1085
  • [29] Application Possibilities of Fused Filament Fabrication Technology for High-Voltage and Medium-Voltage Insulation Systems
    Tichy, Tomas
    Sefl, Ondrej
    Vesely, Petr
    Capal, Tomas
    2019 42ND INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE), 2019,
  • [30] Influence of Neutral-Point Voltage Deviation of PWM Converter on Insulation Monitoring in Medium-Voltage Networks
    Yan, Jun
    Wang, Jinquan
    Xu, Ye
    Wang, Puyu
    Huang, Kefeng
    Hou, Pengfei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (04) : 1730 - 1738