High-throughput single-strand conformation polymorphism analysis by automated capillary electrophoresis: Robust multiplex analysis and pattern-based identification of allelic variants

被引:0
|
作者
Larsen, LA [1 ]
Christiansen, M [1 ]
Vuust, J [1 ]
Andersen, PS [1 ]
机构
[1] Statens Serum Inst, Dept Clin Biochem, DK-2300 Copenhagen S, Denmark
关键词
automated SSCP analysis; capillary electrophoresis; mutation detection; genetic screening; KVLQT1; KCNQ1; HERG; LQT2; MYH7;
D O I
10.1002/(SICI)1098-1004(1999)13:4<318::AID-HUMU9>3.0.CO;2-F
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Genetic diagnosis of an inherited disease or cancer often involves analysis for unknown point mutations in several genes; therefore, rapid and automated techniques that can process a large number of samples are needed. We describe a method for high throughput single strand conformation polymorphism (SSCP) analysis using automated capillary electrophoresis. The operating temperature of a commercially available capillary electrophoresis instrument (ABI PRISM 310) was expanded by installation of a cheap in-house designed cooling system, thereby allowing us to perform automated SSCP analysis at 14-45 degrees C. We have used the method for detection of point mutations associated with the inherited cardiac disorders long QT syndrome (LQTS) and hypertrophic cardiomyopathy (HCM). The sensitivity of the method was 100% when 34 different point mutations were analyzed, including two previously unpublished LQTS-associated mutations (F157C in KVLQT1 and G572R in HERG), as well as eight novel normal variants in HERG and MYH7, The analyzed polymerase chain reaction (PCR) fragments ranged in size from 166 to 1,223 bp. Seventeen different sequence contexts were analyzed. Three different electrophoresis temperatures were used to obtain 100% sensitivity Two mutants could not be detected at temperatures greater than 20 degrees C. The method has a high resolution and good reproducibility and is very robust, making multiplex SSCP analysis and pattern-based identification of known allelic variants as single nucleotide polymorphisms (SNPs) possible. These possibilities, combined with automation and short analysis time, make the method suitable for high-throughput tasks, such as genetic screening. Hum Mutat 13:318-327, 1999. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:318 / 327
页数:10
相关论文
共 50 条
  • [1] High-throughput single-strand conformation polymorphism analysis by capillary electrophoresis
    Ren, JC
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02): : 115 - 128
  • [2] High-throughput single-strand conformation polymorphism analysis on a microfabricated capillary array electrophoresis device
    Tian, HJ
    Emrich, CA
    Scherer, JR
    Mathies, RA
    Andersen, PS
    Larsen, LA
    Christiansen, M
    [J]. ELECTROPHORESIS, 2005, 26 (09) : 1834 - 1842
  • [3] High-throughput single nucleotide polymorphism typing by fluorescent single-strand conformation polymorphism analysis with capillary electrophoresis
    Doi, K
    Doi, H
    Noiri, E
    Nakao, A
    Fujita, T
    Tokunaga, K
    [J]. ELECTROPHORESIS, 2004, 25 (06) : 833 - 838
  • [4] High resolution for single-strand conformation polymorphism analysis by capillary electrophoresis
    Ozawa, S
    Sugano, K
    Sonehara, T
    Fukuzono, S
    Ichikawa, A
    Fukayama, N
    Taylor, M
    Miyahara, Y
    Irie, T
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (20) : 6122 - 6129
  • [5] Analysis of single-strand DNA conformation polymorphism by capillary electrophoresis
    Arakawa, H
    Nakashiro, S
    Maeda, M
    Tsuji, A
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 722 (1-2) : 359 - 368
  • [6] Fluorescence-based single-strand conformation polymorphism analysis of mutations by capillary electrophoresis
    Walz, T
    Geisel, J
    Bodis, M
    Knapp, JP
    Herrmann, W
    [J]. ELECTROPHORESIS, 2000, 21 (02) : 375 - 379
  • [7] High-throughput single-strand conformation polymorphism analysis of an LPL gene mutation by temperature-controlled on-chip capillary electrophoresis
    Ono, Koichi
    Koike, Mitsuyasu
    Ohse, Takuhito
    Takagi, Atsuko
    Ikeda, Yasuyuki
    [J]. 2006 INTERNATIONAL CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE AND BIOLOGY, 2006, : 198 - +
  • [8] High-throughput, high-sensitivity genetic mutation detection by tandem single-strand conformation polymorphism/heteroduplex analysis capillary array electrophoresis
    Kourkine, IV
    Hestekin, CN
    Buchholz, BA
    Barron, AE
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (11) : 2565 - 2572
  • [9] Temperature and pH effects on single-strand conformation polymorphism analysis by capillary electrophoresis
    Ren, JC
    Ueland, PM
    [J]. HUMAN MUTATION, 1999, 13 (06) : 458 - 463
  • [10] Capillary electrophoresis single-strand conformation polymorphism analysis for monitoring soil bacteria
    King, S
    McCord, BR
    Riefler, RG
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 60 (01) : 83 - 92