Immediate Therapeutic Outcomes and Medium-term Follow-up of Percutaneous Balloon Pulmonary Valvuloplasty in Infants with Pulmonary Valve Stenosis: A Single-center Retrospective Study

被引:8
|
作者
Hong, Dian [1 ,2 ]
Qian, Ming-Yang [1 ]
Zhang, Zhi-Wei [1 ]
Wang, Shu-Shui [1 ]
Li, Jun-Jie [1 ]
Li, Yi-Fan [1 ]
Liu, Tian [1 ]
机构
[1] Guangdong Acad Med Sci, Dept Pediat Cardiol, Guangdong Cardiovasc Inst, Guangdong Gen Hosp, Guangzhou 510100, Guangdong, Peoples R China
[2] Shantou Univ, Med Coll, Shantou 515041, Guangdong, Peoples R China
关键词
Balloon Valvuloplasty; Cardiac Catheterization; Infants; Pulmonary Valve Stenosis; CONGENITAL HEART-DISEASE; VALVOTOMY; DETERMINANTS; DILATATION; SURGERY; ATRESIA;
D O I
10.4103/0366-6999.219155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Percutaneous balloon pulmonary valvuloplasty (PBPV) is the preferred therapy for pulmonary valve stenosis (PVS). This study retrospectively reviewed recent PBPV outcomes in infants with PVS. The aim of this study was to evaluate factors associated with immediate therapeutic outcomes and restenosis during medium-term follow-up. Methods: The study included 158 infants with PVS who underwent PBPV from January 2009 to July 2015. Demographic characteristics and patient records were reviewed, including detailed hospitalization parameters, hemodynamic data before and immediately after balloon dilation, cineangiograms, and echocardiograms before PBPV and at each follow-up. All procedures were performed by more than two experienced operators. Results: Immediately after balloon dilation, the pressure gradient across the pulmonary valve decreased from 73.09 +/- 21.89 mmHg (range: 43-151 mmHg) to 24.49 +/- 17.00 mmHg (range: 3-92 mmHg; P < 0.001) and the right ventricular systolic pressure decreased from 95.34 +/- 23.44 mmHg (range: 60-174 mmHg) to 52.07 +/- 18.89 mmHg (range: 22-134 mmHg; P < 0.001). Residual transvalvular pressure gradients of 67.31 +/- 15.19 mmHg (range: 50-92 mmHg) were found in 8.2% of patients, indicating poor therapeutic effects; 6.4% of patients had variable-staged restenosis at follow-up and 3.8% underwent reintervention by balloon dilation or surgical repairs. Further analysis demonstrated that the balloon/annulus ratio showed statistically significant differences (P < 0.05) among groups with different therapeutic effects and between the restenosis and no-stenosis groups. Binary logistic regression analysis further revealed that higher balloon/annulus ratio (odds ratio: 0.005, 95% confidence interval: 0-0.39) was an independent protective factor for restenosis. The rate of severe complications was 1.9%. Conclusions: PBPV is a definitive therapy for infants with PVS based on its effectiveness, feasibility, and safety. Restenosis upon medium-term follow-up is relatively rare.
引用
下载
收藏
页码:2785 / 2792
页数:8
相关论文
共 50 条
  • [41] Percutaneous double-valve balloon valvotomy for multivalve stenosis: Immediate results and intermediate-term follow-up
    Sharma, S
    Loya, YS
    Desai, DM
    Pinto, RJ
    AMERICAN HEART JOURNAL, 1997, 133 (01) : 64 - 70
  • [42] Immediate and long-term follow-up of percutaneous mitral valvuloplasty using Inoue balloon in pregnancy
    Hung Pham
    Pham, Oanh N.
    Nguyen, Viet L.
    Vu, Bien D.
    CIRCULATION, 2012, 125 (19) : E765 - E765
  • [43] Balloon valvuloplasty for critical pulmonary valve stenosis in newborn: A single center ten-year experience
    Alsawah, Gehan Attia
    Hafez, Mona M.
    Matter, Mohamed
    Abo-Haded, Hany M.
    Rakha, Shaimaa
    Almarsafawy, Hala
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2016, 43 : 127 - 131
  • [44] The Yung percutaneous mastoid vent -: A medium-term follow-up study
    Yung, MMW
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1999, 125 (09) : 964 - 968
  • [45] Predictors of immediate results and very long-term follow-up after percutaneous mitral balloon valvuloplasty in rheumatic mitral stenosis
    Meneguz Moreno, R.
    Costa, J. R., Jr.
    Games, N. L.
    Ramos, A. I. O.
    Meneghelo, Z. M.
    Maldonado, M.
    Ferreira Neto, A. N.
    Franca, J. I.
    Siqueira, D.
    Esteves, C.
    Braga, S.
    Sousa, A.
    Sousa, J. E.
    Abizaid, A.
    EUROPEAN HEART JOURNAL, 2017, 38 : 634 - 634
  • [46] Pulmonary atresia with intact ventricular septum. perforation and pulmonary valvuloplasty using a modified mechanical technique.: Medium-term follow-up
    Alcibar-Villa, Juan
    Rubio, Ainhoa
    Pena, Nativiclad
    Galdeano, Jose M.
    Luis, Maite
    Arriola, Josune
    Inguanzo, Ramon
    Perez-Asenjo, Javier
    Aramendi, Jose I.
    Barrenechea, Jose I.
    REVISTA ESPANOLA DE CARDIOLOGIA, 2007, 60 (08): : 833 - 840
  • [47] Comparison of Immediate and Long-term Results between the Single Balloon and Inoue Balloon Techniques for Percutaneous Pulmonary Valvuloplasty
    Liu, Suxuan
    Xu, Xudong
    Liu, Guanzhong
    Ding, Xueyan
    Zhao, Xianxian
    Qin, Yongwen
    HEART LUNG AND CIRCULATION, 2015, 24 (01): : 40 - 45
  • [48] LONG-TERM ECHO-DOPPLER FOLLOW-UP AFTER PERCUTANEOUS PULMONARY VALVULOPLASTY FOR VALVAR STENOSIS OR RESTENOSIS
    VITARELLI, A
    BARILLA, F
    LUZZI, MF
    DIFUSCO, V
    ROSANIO, S
    MAMPIERI, M
    PACE, V
    TEDESCHI, D
    CLINICAL RESEARCH, 1993, 41 (02): : A350 - A350
  • [49] Clinical analysis and medium-term follow-up of simultaneous interventional therapy for compound congenital heart disease in children: a single-center retrospective study
    Ran, Tingting
    Feng, Lingxin
    Li, Mi
    Yi, Qijian
    Zhu, Xu
    Ji, Xiaojuan
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [50] MEDIUM-TERM FOLLOW-UP OF PULMONARY AUTOGRAFT REPLACEMENT OF AORTIC VALVES IN CHILDREN
    ELKINS, RC
    KNOTTCRAIG, CJ
    RANDOLPH, JD
    RAZOOK, JR
    WARD, KE
    OVERHOLT, ED
    LANE, MM
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (07) : 379 - 383