MEDIUM-TERM FOLLOW-UP OF PULMONARY AUTOGRAFT REPLACEMENT OF AORTIC VALVES IN CHILDREN

被引:31
|
作者
ELKINS, RC
KNOTTCRAIG, CJ
RANDOLPH, JD
RAZOOK, JR
WARD, KE
OVERHOLT, ED
LANE, MM
机构
[1] Section of Cardiothoracic Surgery, Dept. Of Surgery, University of Oklahoma Health Sciences Center, OK, 73190
[2] Section of Cardiothoracic Surgery, University of Oklahoma Health Sciences Center, OK, 73190
关键词
GROWTH OF PULMONARY AUTOGRAFT IN CHILDREN;
D O I
10.1016/1010-7940(94)90032-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Pulmonary autograft replacement (PAG) of the aortic valve in children has been shown to be safe and effective with a low incidence of late valve dysfunction. Relief of all types of left ventricular outflow tract obstruction using the pulmonary root has been possible. Concern about the durability of the pulmonary root in the aortic position, and the potential for growth of the pulmonary autograft used either as a root replacement or intraaortic implant, has been questioned. Sixty-five consecutive patients, aged 1.8 to 21 years (mean 12 years) operated on between September 1986 and January 1993, 35 with an intra-aortic implant (IA) and 30 with root replacement (RR), were evaluated by clinical and serial echocardiographic studies (ECHO) up to 6.5 years postoperatively. The hospital mortality rate was 3.0 % (70 % CL 2.1 - 5.1 %). Two patients required reoperation for PAG insufficiency (AI), one for technical malalignment necessitating replacement at 6 months, and one with progressive leaflet prolapse due to adherence of the valve leaflet to a ventricular septal defect (VSD) patch. Freedom from significant aortic regurgitation at 6-year follow-up was 100% for RR and 91+/-6% for IA, and freedom from all valve-related complications including reoperation was 92+/-5% at 6 years. Significant enlargement of the aortic annulus which parallels somatic growth has been measured by ECHO in 17 IA implants (P<0.001) and 17 RR patients (P<0.001) by 1 year, and in 10 IA (P=0.007) and 6 RR (P<0.05) by 2 years. Low risk (mortality 3%), absence of residual or recurrent obstruction, low incidence of recurrent progressive AI, and demonstrated enlargement of the pulmonary autograft appropriate for somatic growth, as well as the absence of dilatation of the autograft root replacement at 6.5 years suggest that the PAG is the ideal replacement for children requiring aortic valve replacement.
引用
收藏
页码:379 / 383
页数:5
相关论文
共 50 条
  • [1] Medium-term follow up of pulmonary autograft aortic valve replacement: Technical advances and echocardiographic follow up
    Linden, PA
    Cohn, LH
    [J]. JOURNAL OF HEART VALVE DISEASE, 2001, 10 (01): : 35 - 42
  • [2] Medium-term follow-up of mechanical valves inserted in children
    Larsen, Signe Holm
    Houlind, Kim
    Hansen, Ole Kromann
    Hjortholm, Kirsten
    Emmertsen, Kristian
    Hjortdal, Vibeke
    [J]. CARDIOLOGY IN THE YOUNG, 2006, 16 (06) : 579 - 585
  • [3] MEDIUM-TERM FOLLOW-UP OF PATIENTS WITH AORTIC VALVE REPLACEMENT: COMPARISON OF MECHANICAL VS TISSUE VALVES
    Ewen, S. A.
    Robertson, M.
    Zamvar, V.
    [J]. HEART, 2010, 96 : A55 - A56
  • [4] Aortic pulmonary autograft implant: Medium-term follow-up with a note on a new right ventricular pulmonary artery conduit
    Masetti, P
    Ussia, GP
    Gazzolo, D
    Marianeschi, SM
    Abella, RF
    Cipriani, A
    Labia, C
    Iorio, FS
    Marcelletti, CF
    [J]. JOURNAL OF CARDIAC SURGERY, 1998, 13 (03) : 173 - 176
  • [5] Total scapular replacement: Medium-term follow-up
    Vrettos, BC
    Wallace, WA
    Neumann, L
    Frostick, SP
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (04) : 472 - 475
  • [6] Long-term follow-up after aortic root replacement with a pulmonary autograft
    Kouchoukos, NT
    Murphy, SF
    Nickerson, NJ
    Schechtman, KB
    DavilaRoman, VG
    [J]. CIRCULATION, 1997, 96 (08) : 2404 - 2404
  • [7] Transcatheter Aortic Valve Replacement for Aortic Stenosis in Small Aortic Annulus: Medium-Term Follow-Up
    Escobar, Artemio Garcia
    Vera, Silvio
    Tebar, Daniel
    Jurado, Alfonso
    Jimenez, Santiago
    Guillermo, Galeote
    Moreno, Raul
    [J]. CIRCULATION, 2022, 146
  • [8] Medium-Term Follow-Up of Early Leaflet Thrombosis After Transcatheter Aortic Valve Replacement
    Ruile, Philipp
    Minners, Jan
    Breitbart, Philipp
    Schoechlin, Simon
    Gick, Michael
    Pache, Gregor
    Neumann, Franz-Josef
    Hein, Manuel
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (12) : 1164 - 1171
  • [9] Aortic root replacement with a pulmonary autograft in young adults: Medium-term results in 70 patients
    Prat, A
    Grandmougin, D
    Decoene, C
    Godart, FR
    de Ibarra, JIS
    Savoye, C
    Goffin, Y
    Stankowiak, C
    [J]. ANNALS OF THORACIC SURGERY, 1998, 66 (06): : S148 - S152
  • [10] Clinical Sequelae of Leaflet Thrombosis Following Transcatheter Aortic Valve Replacement at Medium-Term Follow-Up
    Rashid, Hashrul N.
    Nasis, Arthur
    Gooley, Robert P.
    Cameron, James D.
    Cameron, James D.
    Brown, Adam J.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (18) : 1904 - 1904