The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone

被引:99
|
作者
Kim, DG
Christopherson, GT
Dong, XN
Fyhrie, DP
Yeni, YN
机构
[1] Henry Ford Hosp, Ctr Bone & Joint, Detroit, MI 48202 USA
[2] Univ Calif Davis, Sch Med, Orthopaed Res Labs, Sacramento, CA 95817 USA
关键词
stereology; trabecular bone; micro-CT; resolution; calibration;
D O I
10.1016/j.bone.2004.09.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stereological parameters have been used as an approximation for the architecture of trabecular bone. Structural indices such as bone volume fraction (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), bone surface-to-volume ratio (BS/BV), degree of anisotropy (MIL1/MIL3), and connectivity density (-Euler/Vol) have been widely studied to investigate pathological conditions in bone. Due to its high resolution and nondestructiveness, microcomputed tomography (micro-CT) has been utilized to take precise three-dimensional (3D) images of trabecular microstructures. However, spatial limitations for applying micro-CT-based analyses to large specimens, such as whole vertebral bodies, require using larger scanning and reconstruction voxel sizes. In this study, combinations of three different scanning and reconstruction voxel size were used to represent best possible voxel size (2 1 mum; best in our scanner for the specimen size used) relative to other voxel sizes used in this study, commonly used intermediate voxel sizes (50 mum), and those applicable to scans of whole human vertebral bodies (110 mum) in order to examine the effect of scanning and reconstruction voxel size on stereological measures for human cancellous bone. The error in stereological parameters calculated using combinations of large voxel sizes compared to the gold standard (best possible case) ranged from 0.1% to 102%. The signed magnitude of the error in other cases relative to the gold standard was a function of either scanning or reconstruction voxel size or both (r(2) = 0.55-0.95). For most of the structural indices, the results from analysis of images with larger voxel sizes were correlated with those from the gold standard (r(2) = 0.55-0.99) except for Tb.N at 110/110 mum, MIL1/MIL3 at larger than 110 mum reconstruction voxel size, and -Euler/Vol at any combination of voxel sizes. Overall, it was observed that resampling a high resolution image at lower resolutions (corresponding to increasing reconstruction voxel size in this study) had different effects on the Calculated parameters than scanning at the same low resolution (corresponding to increasing scanning voxel size in this study). Our results show that investigations of image resolution should include actual scans at the resolution of interest rather than simply coarsening of high-resolution images as is customarily done. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1375 / 1382
页数:8
相关论文
共 22 条
  • [1] Effect of microcomputed tomography voxel size on the finite element model accuracy for human cancellous bone
    Yeni, YN
    Christopherson, GT
    Dong, XN
    Kim, DG
    Fyhrie, DP
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 1 - 8
  • [2] The effect of in situ/in vitro three-dimensional quantitative computed tomography image voxel size on the finite element model of human vertebral cancellous bone
    Lu, Yongtao
    Engelke, Klaus
    Glueer, Claus-C
    Morlock, Michael M.
    Huber, Gerd
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (11) : 1208 - 1213
  • [3] The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure
    Tjong, Willy
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Majumdar, Sharmila
    MEDICAL PHYSICS, 2012, 39 (04) : 1893 - 1903
  • [4] The effect of voxel size on image reconstruction in cone-beam computed tomography
    Tanimoto, Hideyuki
    Arai, Yoshinori
    ORAL RADIOLOGY, 2009, 25 (02) : 149 - 153
  • [5] The effect of voxel size on image reconstruction in cone-beam computed tomography
    Hideyuki Tanimoto
    Yoshinori Arai
    Oral Radiology, 2009, 25 : 149 - 153
  • [6] The Effect of Graft Bone Particle Size on Bone Augmentation in a Rabbit Cranial Vertical Augmentation Model: A Microcomputed Tomography Study
    Kon, Kazuhiro
    Shiota, Makoto
    Ozeki, Maho
    Kasugai, Shohei
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) : 402 - 406
  • [7] Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT
    Ye, N.
    Jian, F.
    Lai, W.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [8] DIRECT STEREOLOGICAL ESTIMATION OF 3-D CONNECTIVITY IN HUMAN ILIAC CANCELLOUS BONE - EFFECT OF AGE AND SEX
    YOUNGS, TA
    BOYCE, RW
    MOSEKILDE, L
    SOGAARD, CH
    PADDOCK, CL
    GUNDERSEN, HJG
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S250 - S250
  • [9] Combining ultrasonic and computed tomography scanning to characterize mechanical properties of cancellous bone in necrotic human femoral heads
    Yue, Yue
    Yang, Haisheng
    Li, Yan
    Zhong, Honggang
    Tang, Qi
    Wang, Jiantong
    Wang, Rongtian
    He, Haijun
    Chen, Weiheng
    Chen, Duanduan
    MEDICAL ENGINEERING & PHYSICS, 2019, 66 : 12 - 17
  • [10] Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT: Author response
    Peters, O.
    Maret, D.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)