Effect of microcomputed tomography voxel size on the finite element model accuracy for human cancellous bone

被引:33
|
作者
Yeni, YN [1 ]
Christopherson, GT [1 ]
Dong, XN [1 ]
Kim, DG [1 ]
Fyhrie, DP [1 ]
机构
[1] Henry Ford Hosp, Ctr Bone & Joint, Detroit, MI 48202 USA
关键词
microcomputed tomography; finite element method; voxel size; element size; boundary conditions; accuracy; trabecular bone;
D O I
10.1115/1.1835346
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The level of structural detail that can be acquired and incorporated in a finite element (FE) analysis might greatly influence the results of microcomputed tomography (ACT)based FE simulations, especially when relatively large bones, such as whole vertebrae, are of concern. We evaluated the effect of scanning and reconstruction voxel size on the ACT-based FE analyses of human cancellous tissue samples for fixed- and free-end boundary conditions using different combinations of scan/reconstruction voxel size. We found that the bone volume fraction (BV/TV) did not differ considerably between images scanned at 21 and 50 mu m and reconstructed at 21, 50, or 110 mu m (-0.5% to 7.8% change from the 21/21 mu m case). For the images scanned and reconstructed at 110 mu m, however there was a large increase in BV/TV compared to the 21121 pin case (58.7%). Fixed-end boundary conditions resulted in 1.8% [coefficient of variation (COV)] to 14.6% (E) difference from the free-end case. Dependence of model output parameters on scanning and reconstruction voxel size was similar between free- and fixed-end simulations. Up to 26%, 30%, 17.8%, and 32.3% difference in modulus (E), and average (VMExp), standard deviation (VMSD) and coefficient of variation (COV) of von Mises stresses, respectively, was observed between the 21/21 Am case and other scan/reconstruction combinations wt. thin the same (free or fixed) simulation group. Observed differences were largely attributable to scanning resolution, although reconstruction resolution also contributed significantly at the largest voxel sizes. All 21/21 mu m results (taken as the gold standard) could be predicted from the 21/50 (r(adj)(2) -0.91-0.99; p < 0.001), 21/110 (r(adj)(2) = 0.58-0.99; p < 0.02) and 50/50 results (r(adj)(2) = 0.61-0.97;p < 0.02). While BV/TV VMSD, and VMExp/sigma(2), from the 21/21 could be predicted by those from the 50/110 (r(adj)(2) = 0.63-0.93; p < 0.02) and 110/110 (r(adj)(2) =0.41-0.77,-p < 0.05) simulations as well, Prediction of E, VMExp, and COV became marginally significant (0.04 < p < 0.13) at 50/110 and nonsignificant at 110/110 (0.21 < p < 0.70). In conclusion, calculation of cancellous bone modulus, mean trabecular stress, and other parameters are subject to large errors at 110/110 Am voxel size. However enough microstructural details for studying bone volume fraction, trabecular shear stress scatter, and trabecular shear stress amplification (VMExp/sigma(2),) can be resolved using a 21/110 mu m, 50/110 mu m, and 110/110 mu m voxels for both free- and fixed-end constraints.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [1] The effect of microcomputed tomography scanning and reconstruction voxel size on the accuracy of stereological measurements in human cancellous bone
    Kim, DG
    Christopherson, GT
    Dong, XN
    Fyhrie, DP
    Yeni, YN
    BONE, 2004, 35 (06) : 1375 - 1382
  • [2] The effect of in situ/in vitro three-dimensional quantitative computed tomography image voxel size on the finite element model of human vertebral cancellous bone
    Lu, Yongtao
    Engelke, Klaus
    Glueer, Claus-C
    Morlock, Michael M.
    Huber, Gerd
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (11) : 1208 - 1213
  • [3] Influence of the specimen scan condition on the finite element voxel model of human vertebral cancellous bone
    Lu, Yongtao
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2015, 3 (03): : 172 - 176
  • [4] Trabecular surface remodeling simulation for cancellous bone using microstructural voxel finite element models
    Adachi, T
    Tsubota, K
    Tomita, Y
    Hollister, SJ
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05): : 403 - 409
  • [5] The Effect of Graft Bone Particle Size on Bone Augmentation in a Rabbit Cranial Vertical Augmentation Model: A Microcomputed Tomography Study
    Kon, Kazuhiro
    Shiota, Makoto
    Ozeki, Maho
    Kasugai, Shohei
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (02) : 402 - 406
  • [6] Influence of Cancellous Bone Existence in Human Lumbar Spine: A Finite Element Analysis
    Alizadeh, M.
    Kashani, J.
    Kadir, M. R. Abdul
    Fallahi, A.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 439 - +
  • [7] Finite Element Simulation of the Fatigue Behaviour of Cancellous Bone*
    M. Taylor
    J. Cotton
    P. Zioupos
    Meccanica, 2002, 37 : 419 - 429
  • [8] Finite element simulation of the fatigue behaviour of cancellous bone
    Taylor, M
    Cotton, J
    Zioupos, P
    MECCANICA, 2002, 37 (4-5) : 419 - 429
  • [9] Early morphometric and anisotropic change in periarticular cancellous bone in a model of experimental knee osteoarthritis quantified using microcomputed tomography
    Boyd, SK
    Müller, R
    Matyas, JR
    Wohl, GR
    Zernicke, RF
    CLINICAL BIOMECHANICS, 2000, 15 (08) : 624 - 631
  • [10] Large-Scale Finite Element Analysis of Human Cancellous Bone Tissue Micro Computer Tomography Data: A Convergence Study
    Chen, Yuan
    Pani, Martino
    Taddei, Fulvia
    Mazza, Claudia
    Li, Xinshan
    Viceconti, Marco
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2014, 136 (10):