First results of ion trapping in the Dresden EBIT II

被引:3
|
作者
Kentsch, U
Zschornack, G
Grossmann, F
Ovsyannikov, VP
Ullmann, F
机构
[1] Tech Univ Dresden, Inst Kern & Teilchenphys, D-01069 Dresden, Germany
[2] Leybold Vakuum Dresden GmbH, D-01109 Dresden, Germany
来源
HYPERFINE INTERACTIONS | 2003年 / 146卷 / 1-4期
关键词
highly charged ions; ion trap; xenon ions; EBIT;
D O I
10.1023/B:HYPE.0000004244.21906.64
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
With the Dresden EBIT it is possible to produce highly charged ions in a compact, economical and long-term stable ion source working at room temperature. The operation principle is based on electron impact ionization of primarily neutral atoms in a high-density electron beam in combination with electrical potentials for axial trapping. Radial trapping is realized by the negative space charge of the electron beam itself. After build-up the first Dresden EBIT in 1999 first results from a second EBIT device, the so-called Dresden EBIT II are presented. By means of X-ray spectroscopy we analyze the influence of different source parameters as ion trapping time, height of wall potentials and pressure on the production and storage of highly charged xenon ions.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [22] The Dresden EBIT: a novel source of x-rays from highly charged ions
    Kentsch, U
    Landgraf, S
    Zschornack, G
    Grossmann, F
    Ovsyannikov, VP
    Ullmann, F
    X-RAY SPECTROMETRY, 2004, 33 (01) : 33 - 38
  • [23] Recent results from the spare low temperature Astro-E microcalorimeter used at the LLNL EBIT-I and EBIT-II
    Brown, GV
    Behar, E
    Beiersdorfer, P
    Boyce, KR
    Chen, H
    Gendreau, KC
    Gygax, J
    Kahn, SM
    Kelley, RL
    Porter, FS
    Stahle, CK
    Szymkowiak, AE
    LOW TEMPERATURE DETECTORS, 2002, 605 : 413 - 416
  • [24] ION TRAPPING IN TURBULENT COUNTERFLOW OF HELIUM II
    ASHTON, PA
    NORTHBY, JA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 460 - 460
  • [25] Recent results from the Oxford EBIT
    Crosby, DN
    Ezekiel, TZ
    Green, FM
    Smith, CJ
    Silver, JD
    NINTH INTERNATIONAL SYMPOSIUM ON ELECTRON BEAM ION SOURCES AND TRAPS AND THEIR APPLICATIONS, 2004, 2 : 9 - 19
  • [26] The Dresden high-magnetic field laboratory -: overview and first results
    Krug, H
    Doerr, M
    Eckert, D
    Eschrig, H
    Fischer, F
    Fulde, P
    Groessinger, R
    Handstein, A
    Herlach, F
    Hinz, D
    Kratz, R
    Loewenhaupt, M
    Müller, KH
    Pobell, F
    Schultz, L
    Siegel, H
    PHYSICA B, 2001, 294 (294-295): : 605 - 611
  • [27] The Heidelberg EBIT:: Present results and future perspectives
    Martinez, A. J. Gonzalez
    Lopez-Urrutia, J. R. Crespo
    Fischer, D.
    Orts, R. Soria
    Ullrich, J.
    PHYSICS AT ELECTRON BEAM ION TRAPS AND ADVANCED RESEARCH LIGHT SOURCES 2005, 2007, 72
  • [28] Recent results from EBIT-II using a spare Astro-E microcalorimeter
    Brown, GV
    Behar, E
    Beiersdorfer, P
    Boyce, KR
    Chen, H
    Gendreau, KC
    Gygax, J
    Kahn, SM
    Kelley, RL
    Porter, FS
    Stahle, CK
    Szymkowiak, AE
    NEW CENTURY OF X-RAY ASTRONOMY, 2001, 251 : 524 - 525
  • [29] Modelling of ion accumulation processes in EBIS and EBIT
    Kalagin, IV
    Kuchler, D
    Ovsyannikov, VP
    Zschornack, G
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 1998, 7 (04): : 441 - 457
  • [30] EBIT. Electron beam ion trap
    Levine, M.A.
    Marrs, R.E.
    Bennett, C.L.
    Henderson, J.R.
    Knapp, D.A.
    Schneider, M.B.
    AIP Conference Proceedings, 1988, 188