Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

被引:6
|
作者
Kudo, K
Takeda, N
Uritani, A
Koshikawa, S
Shibata, Y
Kobayashi, K
Yoshimoto, T
机构
[1] Natl Inst AIST, Quantum Radiat Div, NMIJ, Tsukuba, Ibaraki 3058568, Japan
[2] Kyoto Univ, Inst Res Reactor, Osaka 5900494, Japan
关键词
thermal neutrons; response function; He-3 proportional counter; Monte Carlo code;
D O I
10.1016/S0168-583X(03)01633-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The gas multiplication distributions along the anode wires of He-3 proportional counters with different sensitive lengths of 10, 15 and 20 cm were measured using a collimated thermal neutron beam at the Kyoto University Reactor facility. The ideal response function excluding the effect of electric field distortion near the boundaries of the anode wire was derived by taking into account the difference between pulse height spectra measured by two different length counters. The pulse height spectrum calculated by the NRESPG Monte Carlo code assuming the ideal gas multiplication region showed relatively good agreement with the response function derived from the measurements. Both the energy resolution of the full energy peak at 764 keV and the peak ratio to the entire pulse height spectrum were improved markedly. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:305 / 309
页数:5
相关论文
共 50 条
  • [41] Investigation of a lithium foil multi-wire proportional counter for potential 3He replacement
    Nelson, Kyle A.
    Bellinger, Steven L.
    Montag, Benjamin W.
    Neihart, James L.
    Riedel, Todd A.
    Schmidt, Aaron J.
    McGregor, Douglas S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 669 : 79 - 84
  • [42] Lithium Glass Scintillator Neutron Detector as an Improved Alternative to the Standard 3He Proportional Counter
    Popov, Vladimir
    Degtiarenko, Pavel
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1819 - 1822
  • [43] INFLUENCE OF DIRECTION OF CHARGED-PARTICLES PRODUCED BY THERMAL-NEUTRONS ON PULSE-HEIGHT IN HE-3 PROPORTIONAL-COUNTERS
    TAKEDA, N
    KUDO, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 548 - 551
  • [44] Transverse electron scattering response function of 3He
    Della Monaca, Sara
    Efros, Victor D.
    Khugaev, Avas
    Leidemann, Winfried
    Orlandini, Giuseppina
    Tomusiak, Edward L.
    Yuan, Luping P.
    PHYSICAL REVIEW C, 2008, 77 (04):
  • [45] RESPONSE FUNCTION FOR 3He NEUTRON SPECTROMETERS.
    Beimer, Klaes-Hakan
    Nyman, Goran
    Tengblad, Olof
    Nuclear instruments and methods in physics research, 1986, 245 (2-3): : 402 - 414
  • [46] The transverse electron scattering response function of 3He
    G. Orlandini
    S. Della Monaca
    V. D. Efros
    A. Khugaev
    W. Leidemann
    E. L. Tomusiak
    L. Yuan
    Few-Body Systems, 2008, 44 : 329 - 331
  • [47] LOW-LEVEL GAMMA AND NEUTRON MONITORING BASED ON USE OF PROPORTIONAL COUNTER FILLED WITH 3HE IN POLYTHENE MODERATOR: STUDY OF THE RESPONSES TO GAMMA AND NEUTRONS
    Pszona, S.
    Bantsar, A.
    Tulik, P.
    Wincel, K.
    Zareba, B.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 237 - 240
  • [48] The transverse electron scattering response function of 3He
    Orlandini, G.
    Della Monaca, S.
    Efros, V. D.
    Khugaev, A.
    Leidemann, W.
    Tomusiak, E. L.
    Yuan, L.
    FEW-BODY SYSTEMS, 2008, 44 (1-4) : 329 - 331
  • [49] Novel and efficient 10B lined tubelet detector as a replacement for 3He neutron proportional counters
    Tsorbatzoglou, Kyriakos
    McKeag, Robert D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 381 - 383
  • [50] Time-spatial neutron measurement by using position-sensitive 3He proportional counter
    Kitamura, Y
    Misawa, T
    Unesaki, H
    Shiroya, S
    Uritani, A
    Ishitani, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 64 - 68