Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

被引:6
|
作者
Kudo, K
Takeda, N
Uritani, A
Koshikawa, S
Shibata, Y
Kobayashi, K
Yoshimoto, T
机构
[1] Natl Inst AIST, Quantum Radiat Div, NMIJ, Tsukuba, Ibaraki 3058568, Japan
[2] Kyoto Univ, Inst Res Reactor, Osaka 5900494, Japan
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS | 2004年 / 213卷
关键词
thermal neutrons; response function; He-3 proportional counter; Monte Carlo code;
D O I
10.1016/S0168-583X(03)01633-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The gas multiplication distributions along the anode wires of He-3 proportional counters with different sensitive lengths of 10, 15 and 20 cm were measured using a collimated thermal neutron beam at the Kyoto University Reactor facility. The ideal response function excluding the effect of electric field distortion near the boundaries of the anode wire was derived by taking into account the difference between pulse height spectra measured by two different length counters. The pulse height spectrum calculated by the NRESPG Monte Carlo code assuming the ideal gas multiplication region showed relatively good agreement with the response function derived from the measurements. Both the energy resolution of the full energy peak at 764 keV and the peak ratio to the entire pulse height spectrum were improved markedly. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:305 / 309
页数:5
相关论文
共 50 条
  • [31] Position-dependent neutron detection efficiency loss in 3He gas proportional counters
    Peplowski, Patrick N.
    Yokley, Zachary W.
    Liebel, Madison
    Cheng, Shuo
    Elphic, Richard C.
    Hoogerheide, Shannon F.
    Lawrence, David J.
    Nico, Jeffrey S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 982
  • [32] MEASUREMENTS OF CONTAMINATED d plus D NEUTRONS IN d plus T NEUTRON FIELDS BY USING A 3He PROPORTIONAL COUNTER.
    Kudo, K.
    Michikawa, T.
    Kinoshita, T.
    1600, (A249): : 2 - 3
  • [33] DEVELOPMENT OF POSITION-SENSITIVE HE-3 PROPORTIONAL COUNTER FOR THERMAL-NEUTRONS WITH NOVEL SIGNAL READOUT
    URITANI, A
    MORI, C
    WATANABE, T
    MIYAHARA, A
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1990, 27 (08) : 712 - 717
  • [34] ANALYSIS OF TRITIUM AND 3He TRACKS USING A MASS SPECTROMETER AND PROPORTIONAL COUNTER.
    Mamyrin, B.A.
    Akulov, Yu.A.
    Khabarin, L.V.
    Yudenich, V.S.
    Soviet physics. Technical physics, 1983, 28 (06): : 690 - 692
  • [35] Flat-type 3He proportional counter for ultracold neutron (UCN) detection
    Yoshiki, Hajime
    Yamaguchi, Hiroshi
    Ishimoto, Shigeru
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A343 (2-3) : 573 - 582
  • [36] Neutron response function for a detector with 3He counters for the 0.39-1.54 MeV neutron energy range
    Cerny, J
    Dlouhy, Z
    Dolezal, Z
    Ivanov, MP
    Kubik, P
    Kuznetsova, EA
    Penionzkevich, YE
    Sokol, EA
    Svejda, J
    Wilhelm, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 540 (2-3): : 430 - 436
  • [37] High-voltage micro discharge in ultra-low background 3He proportional counters
    Heeger, KM
    Elliott, SR
    Rbertson, RGH
    Smith, MWE
    Steiger, TD
    Wilkerson, JF
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 838 - 842
  • [38] 3He neutron proportional counter performance in high gamma-ray dose environments
    Beddingfield, DH
    Johnson, NH
    Menlove, HO
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 455 (03): : 670 - 682
  • [39] Comparison of neutron scintillation detectors with a 3He proportional counter for the Spallation Neutron Source, SNS
    Engels, R
    Kemmerling, G
    Rongen, H
    Schelten, J
    Cooper, R
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 338 - 340
  • [40] Comparison of neutron scintillation detectors with a 3He proportional counter for the spallation neutron source (SNS)
    Engels, R
    Kemmerling, G
    Rongen, H
    Schelten, J
    Cooper, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) : 923 - 925