Evaluation of effective dose from a RANDO phantom in videofluorography diagnostic procedures for diagnosing dysphagia

被引:8
|
作者
Iwai, K. [1 ]
Hashimoto, K.
Nishizawa, K. [2 ]
Sawada, K.
Honda, K.
机构
[1] Nihon Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Chiyoda Ku, Tokyo 1018310, Japan
[2] Natl Inst Radiol Sci, Div Med Phys, Chiba 260, Japan
关键词
effective dose; equivalent dose; videofluorography; dysphagia; PHARYNGEAL WALL; PATIENT; SWALLOW;
D O I
10.1259/dmfr/51307488
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Videofluorography (VF) is useful for diagnosing dysphagia; however, few reports have investigated appropriate effective doses for VF. The present study aimed to estimate the effective radiation dose in VF for diagnosis of dysphagia. Methods: Radiation doses to tissues and organs were measured using the anthropomorphic RANDO woman phantom as an equivalent to the human body. Effective doses were estimated according to the recommendations of the International Commission on Radiological Protection (ICRP) 60 in 1990 and IRCP 103 in 2007. The tissues measured were those recommended by ICRP 60 and ICRP 103 including gonads (ovaries and testes), red bone marrow and tissues in which excessive radiation commonly causes malignant tumours including lung, thyroid gland, stomach, large intestine, liver, oesophagus, bladder, breast, bone marrow, skin, brain and salivary gland. Skin dose was also measured using thermoluminescent dosimeters. Results: Using ICRP 103, the effective dose was estimated as 118.1 mu Sv at a tube voltage of 50 kV and 82.4 mu Sv at 45 kV. However, using ICRP 60 the effective dose for 1 min of VF was estimated at 62.4 mu Sv and 47.2 mu Sv under the same exposure conditions. Conclusions: Using ICRP 103, the effective dose for VF per examination at a total estimation time of 1 min was estimated as approximately 2.5-8.3 times that observed for digital panoramic radiography and 1/12 to 3 times depending on the measurement device for cone beam CT (CBCT). This value can be decreased in the future using a smaller irradiation field and decreased time for examination in VF in the future. Dentomaxillofacial Radiology (2011) 40, 96-101. doi: 10.1259/dmfr/51307488
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [1] OPTIMIZATION NEED OF DENTAL RADIODIAGNOSTIC PROCEDURES - RESULTS OF EFFECTIVE DOSE EVALUATION FROM RANDO PHANTOM MEASUREMENTS
    BORIO, R
    CHIOCCHINI, S
    CICIONI, R
    ESPOSTI, PD
    RONGONI, A
    SABATINI, P
    SAETTA, DMS
    REGI, L
    CAPRINO, G
    RADIATION PROTECTION DOSIMETRY, 1994, 51 (02) : 137 - 140
  • [2] EVALUATION OF EFFECTIVE DOSE EQUIVALENT FROM DIAGNOSTIC SPECIAL PROCEDURES
    SADAGOPAN, G
    SUPE, SJ
    HEALTH PHYSICS, 1985, 48 (06): : 824 - 825
  • [3] ESTIMATION OF THE MEAN ORGAN DOSES AND THE EFFECTIVE DOSE EQUIVALENT FROM RANDO PHANTOM MEASUREMENTS
    GOLIKOV, VY
    NIKITIN, VV
    HEALTH PHYSICS, 1989, 56 (01): : 111 - 115
  • [4] Estimating Effective Dose from Phantom Dose Measurements in Atrial Fibrillation Ablation Procedures
    Anderson-Evans, C.
    Wallace, T.
    Toncheva, G.
    Hranitzky, E.
    Hurwitz, L.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] ESTIMATION OF MEAN ORGAN DOSES IN DIAGNOSTIC-RADIOLOGY FROM RANDO PHANTOM MEASUREMENTS
    HUDA, W
    SANDISON, GA
    HEALTH PHYSICS, 1984, 47 (03): : 463 - 467
  • [6] Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements
    Aragno, D
    Fattibene, P
    Onori, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2671 - 2683
  • [7] Effective dose from diagnostic nuclear medicine procedures in northern Greece
    Hatziioannou, KA
    Hatzigiannaki, A
    MolyvdaAthanasopoulou, E
    Sioundas, A
    Kostaki, P
    Psarrakos, K
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C494 - C496
  • [8] Estimation of organ dose equivalents from residents of radiation-contaminated buildings with Rando phantom measurements
    Lee, JS
    Dong, SL
    Wu, TH
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (05) : 867 - 873
  • [9] Effective dose from diagnostic procedures - Should this be recorded for radiation therapy patients?
    Lea, AC
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S191 - S191
  • [10] Organ and effective dose evaluation in diagnostic radiology based on in-phantom dose measurements with novel photodiode-dosemeters
    Kawaura, Chiyo
    Aoyama, Takahiko
    Koyama, Shuji
    Achiwa, Masataka
    Mori, Masaki
    RADIATION PROTECTION DOSIMETRY, 2006, 118 (04) : 421 - 430