Comparison of Reactive Gaseous Mercury Collection by Different Sampling Methods in a Laboratory Test and Field Monitoring

被引:21
|
作者
Bu, Xiaoge [1 ]
Zhang, Hefeng [1 ]
Lv, Guangkuo [1 ]
Lin, Huiming [2 ]
Chen, Long [3 ]
Yin, Xiufeng [4 ]
Shen, Guofeng [2 ]
Yuan, Wen [2 ]
Zhang, Wei [5 ]
Wang, Xuejun [2 ]
Tong, Yindong [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[2] Peking Univ, Coll Urban & Environm Sci, Beijing 100871, Peoples R China
[3] East China Normal Univ, Sch Geog Sci, Shanghai 200241, Peoples R China
[4] Chinese Acad Sci, Northwest Inst Ecoenvironm & Resources, State Key Lab Cryospher Sci, Lanzhou 730000, Gansu, Peoples R China
[5] Renmin Univ China, Sch Environm & Nat Resources, Beijing 100872, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
SPECIATED ATMOSPHERIC MERCURY; CATION-EXCHANGE MEMBRANES; KCL-COATED DENUDERS; AMBIENT AIR; PHOTOLYTIC REDUCTION; MINAMATA CONVENTION; ELEMENTAL MERCURY; WET DEPOSITION; AEROSOLS; CHINA;
D O I
10.1021/acs.estlett.8b00439
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Accurately measuring reactive gaseous mercury (RGM) concentrations in the atmosphere is important to improve our understanding of the global mercury (Hg) cycle. In this study, we compared the RGM collection efficiencies of four sampling methods, including a 14 cm long KCl-coated denuder, a KCl-coated glass fiber filter, a KCl-coated quartz sand tube, and a cation exchange membrane. Both laboratory studies and field RGM monito ring were performed in environments with low humidity [relative humidity (RH) of similar to 20%], medium humidity (RH of S0-70%), and high humidity (RH of similar to 100%). Laboratory results showed that in environments with <70% RH, RGM amounts collected by the KCl-coated glass fiber filter and the KCl-coated quartz sand tube were comparable with those collected with the cation exchange membrane. In environments with similar to 100% RH, the cation exchange membrane collected more RGM, approximately 1.1-1.4, 1.1-1.2, and 2.4-2.7 times more than the KCl-coated glass fiber filter, KCl-coated quartz sand tube, and KCl-coated denuder, respectively. During field monitoring, RGM amounts collected with the KCl-coated quartz sand tube were comparable to those collected with the cation exchange membrane regardless of the RH in the environment (p > 0.05; n = 60). Large variations (<= 20 during field monitoring) in RGM concentrations measured by different sampling methods indicate the need for a unified and standardized method for future RGM monitoring.
引用
收藏
页码:600 / 607
页数:15
相关论文
共 50 条
  • [1] Comparison of field and laboratory methods for monitoring metallic mercury vapor in indoor air
    Singhvi, R
    Turpin, R
    Kalnicky, DJ
    Patel, J
    JOURNAL OF HAZARDOUS MATERIALS, 2001, 83 (1-2) : 1 - 10
  • [2] Laboratory comparison of sampling methods for reactive isocyanate vapors and aerosols
    Rando, RJ
    Poovey, HG
    Mokadam, DR
    ISOCYANATES: SAMPLING, ANALYSIS, AND HEALTH EFFECTS, 2001, 1408 : 21 - 37
  • [3] Atmospheric mercury speciation: Laboratory and field evaluation of a mist chamber method for measuring reactive gaseous mercury
    Stratton, WJ
    Lindberg, SE
    Perry, CJ
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (01) : 170 - 177
  • [4] Comparison of 4 Methods for Measurement of Reactive, Gaseous Oxidized, and Particulate Bound Mercury
    Gustin, Mae Sexauer
    Dunham-Cheatham, Sarrah M.
    Zhang, Lei
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (24) : 14489 - 14495
  • [5] Measurement of Particulate Bound Mercury, Gaseous Elemental Mercury, and Reactive Gaseous Mercury Concentrations by Using an Ambient Air Mercury Collection System
    Fang, Guor-Cheng
    Kuo, Yu-Chen
    Zhuang, Yuan-Jie
    Cho, Meng-Hsien
    ENVIRONMENTAL FORENSICS, 2015, 16 (04) : 305 - 309
  • [6] An examination of methods for the measurements of reactive gaseous mercury in the atmosphere
    Sheu, GR
    Mason, RP
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (06) : 1209 - 1216
  • [7] FIELD INTERCOMPARISON OF FILTER PACK AND DENUDER SAMPLING METHODS FOR REACTIVE GASEOUS AND PARTICULATE POLLUTANTS
    HARRISON, RM
    KITTO, AMN
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1990, 24 (10): : 2633 - 2640
  • [8] Field comparison of fugitive tailings dust sampling and monitoring methods
    Cleaver, Amy E.
    White, H. Peter
    Rickwood, Carrie J.
    Jamieson, Heather E.
    Huntsman, Philippa
    SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 823
  • [9] Analysis Methods, Occurrence, and Transformation of Reactive Gaseous Mercury in the Atmosphere
    Fang, Yingying
    Wang, Ying
    Shi, Jianbo
    Yin, Yongguang
    Cai, Yong
    Jiang, Guibin
    PROGRESS IN CHEMISTRY, 2021, 33 (01) : 151 - 161
  • [10] Laboratory simulation of field sampling: Comparison with ideal sampling and field data
    Santagata, M
    Sinfield, JV
    Germaine, JT
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2006, 132 (03) : 351 - 362