Reconstructing bulk isotope ratios from compound-specific isotope ratios

被引:11
|
作者
Morrison, Douglas J. [1 ]
Cooper, Karen [1 ]
Preston, Tom [1 ]
机构
[1] SUERC, Stable Isotope Biochem Lab, Glasgow G75 0QF, Lanark, Scotland
关键词
MASS-SPECTROMETRY;
D O I
10.1002/rcm.4577
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Carbon isotope analysis by bulk elemental analysis coupled with isotope ratio mass spectrometry has been the mainstay of delta C-13 analyses both at natural abundance and in tracer studies. More recently, compound-specific isotope analysis (CSIA) has become established, whereby organic constituents are separated online by gas or liquid chromatography before oxidation and analysis of CO2 for constituent delta C-13. Theoretically, there should be concordance between bulk delta C-13 measurements and carbon-weighted delta C-13 measurements of carbon-containing constituents. To test the concordance between the bulk and CSIA, fish oil was chosen because the majority of carbon in fish oil is in the triacylglycerol form and similar to 95% of this carbon is amenable to CSIA in the form of fatty acids. Bulk isotope analysis was carried out on aliquots of oil extracted from 55 fish samples and delta C-13 values were obtained. Free fatty acids (FFAs) were produced from the oil samples by saponification and derivatised to fatty acid methyl esters (FAMEs) for CSIA by gas chromatography/combustion/isotope ratio mass spectrometry. A known amount of an internal standard (C15:0 FAME) was added to allow analyte quantitation. This internal standard was also isotopically calibrated in both its FFA (delta C-13 = 34.30 parts per thousand) and FAME (delta C-13 = 34.94 parts per thousand,) form. This allowed reporting of FFA delta C-13 from measured FAME delta C-13 values. The bulk delta C-13 was reconstructed from CSIA data based on each FFA delta C-13 and the relative amount of CO2 produced by each analyte. The measured bulk mean delta C-13 (SD) was 23.75 parts per thousand (1.57 parts per thousand) compared with the reconstructed bulk mean delta C-13 of 23.76 (1.44 parts per thousand) from CSIA and was not significantly different. Further analysis of the data by the Bland-Altman method did not show particular bias in the data relative to the magnitude of the measurement. Good agreement between the methods was observed with the mean difference between methods (range) of 0.01 parts per thousand (-1.50 to 1.30). Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1799 / 1804
页数:6
相关论文
共 50 条
  • [1] Demonstration of Compound-Specific Isotope Analysis of Hydrogen Isotope Ratios in Chlorinated Ethenes
    Kuder, Tomasz
    Philp, Paul
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (03) : 1461 - 1467
  • [2] Measuring carbon isotope ratios of microphytobenthos using compound-specific stable isotope analysis of phytol
    Oakes, JM
    Revill, AT
    Connolly, RM
    Blackburn, SI
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2005, 3 : 511 - 519
  • [3] Compound-Specific Stable Carbon Isotope Ratios of Terrestrial Biomarkers in Urban Aerosols from Beijing, China
    Ren, Lujie
    Hu, Wei
    Hou, Juzhi
    Li, Linjie
    Yue, Siyao
    Sun, Yele
    Wang, Zifa
    Li, Xiaodong
    Pavuluri, Chandra Mouli
    Hou, Shengjie
    Liu, Cong-Qiang
    Kawamura, Kimitaka
    Ellam, Robert Mark
    Fu, Pingqing
    ACS EARTH AND SPACE CHEMISTRY, 2019, 3 (09): : 1896 - 1904
  • [4] Determination of compound-specific carbon isotope ratios of chlorinated methanes, ethanes, and ethenes in aqueous samples
    Hunkeler, D
    Aravena, R
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (13) : 2839 - 2844
  • [5] Compound-Specific Isotope Geochemistry in the Ocean
    Close, Hilary G.
    ANNUAL REVIEW OF MARINE SCIENCE, VOL 11, 2019, 11 : 27 - +
  • [6] Characterization of the origin of coalbed gases in southeastern Illinois Basin by compound-specific carbon and hydrogen stable isotope ratios
    Strapoc, Dariusz
    Mastalerz, Maria
    Eble, Cortland
    Schimmelmann, Arndt
    ORGANIC GEOCHEMISTRY, 2007, 38 (02) : 267 - 287
  • [7] Variation of compound-specific hydrogen isotope ratios under changing temperature program in gas chromatography/thermal conversion/isotope ratio mass spectrometry
    Liu, Weiguo
    Wang, Zheng
    Cui, Linlin
    Sauer, Peter E.
    Cao, Yunning
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (16) : 1746 - 1752
  • [8] Effects of decalcification on bulk and compound-specific nitrogen and carbon isotope analyses of dentin
    Brault, Emily K.
    Koch, Paul L.
    Gier, Elizabeth
    Ruiz-Cooley, R. I.
    Zupcic, Jessica
    Gilbert, Kwasi N.
    McCarthy, Matthew D.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (24) : 2744 - 2752
  • [9] Compound-specific stable carbon isotope ratios of phenols and nitrophenols derivatized with N,O-bis(trimethylsilyl)trifluoroacetamide
    Irei, Satoshi
    Rudolph, Jochen
    Huang, Lin
    ANALYTICA CHIMICA ACTA, 2013, 786 : 95 - 102
  • [10] Compound-specific chlorine isotope ratios of TCE, PCE and DCE isomers by direct injection using CF-IRMS
    Shouakar-Stash, Orfan
    Drimmie, Robert J.
    Zhang, Min
    Frape, Shaun K.
    APPLIED GEOCHEMISTRY, 2006, 21 (05) : 766 - 781