Compound-specific chlorine isotope ratios of TCE, PCE and DCE isomers by direct injection using CF-IRMS

被引:90
|
作者
Shouakar-Stash, Orfan [1 ]
Drimmie, Robert J. [1 ]
Zhang, Min [1 ]
Frape, Shaun K. [1 ]
机构
[1] Univ Waterloo, Dept Earth Sci, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1016/j.apgeochem.2006.02.006
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A method for determining compound-specific Cl isotopic compositions (delta Cl-37) was developed for tetrachloroethene (PCE), trichloroethene (TCE), cis-dichloroethene (cis-DCE), trans-dichloroethene (trans-DCE) and 1,1-dichloroethene (1,1-DCE). The isotope ratio mass spectrometry (IRMS) used in this study has nine collectors, including two for m/z 50 and 52 (CH3Cl) and two for m/z 94 and 96 (CH3Br). The development of this method is based on the fact that fragments with mass ratios of 94/96, 95/97 and 96/98 are produced from PCE, TCE and DCE isomers during ion bombardment in the source of a mass spectrometer. Using continuous flow isotope ratio mass spectrometry coupled with gas chromatography (GC-CF-IRMS), it is possible to separate these compounds on-line and directly measure the Cl isotopic ratios of the fragments with the specific mass ratios. Both pure phase and aqueous samples were used for Cl isotopic analysis. For pure phase samples, a vapour phase of the chlorinated ethenes was injected directly into the GC, whereas the solid. phase micro extraction (SPME) method was used to extract these compounds from aqueous solutions. The precisions of this analytical technique were +/- 0.12 parts per thousand (1 sigma, n = 30), 0.06%. (1 sigma, n = 30), and +/- 0.08 parts per thousand (1 sigma, n = 15) for PCE, TCE and DCE isomers, respectively. The limits of quantification (LOQ) for analyzing Cl isotopic composition in aqueous solutions were 20, 5, and 5 mu g/L for PCE, TCE and DCE isomers, respectively. This corresponds to 6-9 nano-mole of Cl, which is approximately 80 times lower than the most sensitive existing method. Compared to methods previously available, this new development offers the following advantages: (1) The much lower LOQ make it possible to extract these compounds directly from aqueous solutions using SPME without pre-concentration; (2) The linking of a GC with an IRMS eliminates off-line separation; and (3) Because the fragments used for isotopic ratio measurement are produced during ion bombardment in the mass spectrometer, there is no need to convert chlorinated ethenes to methyl chloride. As a result, this technique greatly enhances the efficiency for isotopic analysis by eliminating procedures for pre-concentration, off-line separation and sample preparation. In addition, it also reduces the potential for isotopic fractionation introduced during these procedures. Compound-specific Cl stable isotope analysis can be used as a tool to study the sources of organic contaminants in groundwater and their behaviour in the subsurface environments. It may also assist in understanding processes such as transport, mixing, and degradation reactions. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:766 / 781
页数:16
相关论文
共 22 条
  • [1] Fingerprinting TCE in a Bedrock Aquifer Using Compound-Specific Isotope Analysis
    Lojkasek-Lima, Paulo
    Aravena, Ramon
    Parker, Beth L.
    Cherry, John A.
    GROUND WATER, 2012, 50 (05) : 754 - 764
  • [2] Monitoring microbial dechlorination of tetrachloroethene (PCE) in groundwater using compound-specific stable carbon isotope ratios: Microcosm and field studies
    Hunkeler, D
    Aravena, R
    Butler, BJ
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (16) : 2733 - 2738
  • [3] Monitoring and evaluation of dechlorination processes using compound-specific chlorine isotope analysis
    Sakaguchi-Soeder, Kaori
    Jager, Johannes
    Grund, Harald
    Matthaeus, Felix
    Schueth, Christoph
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (18) : 3077 - 3084
  • [4] Direct Compound-Specific Stable Chlorine Isotope Analysis of Organic Compounds with Quadrupole GC/MS Using Standard Isotope Bracketing
    Aeppli, Christoph
    Holmstrand, Henry
    Andersson, Per
    Gustafsson, Orjan
    ANALYTICAL CHEMISTRY, 2010, 82 (01) : 420 - 426
  • [5] Measuring carbon isotope ratios of microphytobenthos using compound-specific stable isotope analysis of phytol
    Oakes, JM
    Revill, AT
    Connolly, RM
    Blackburn, SI
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2005, 3 : 511 - 519
  • [6] Measurement of compound-specific carbon isotope ratios (13C values) via direct injection of whole crude oil samples
    Barrie, Craig D.
    Taylor, Kyle W. R.
    Zumberge, John
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (07) : 843 - 853
  • [7] Optimization of compound-specific chlorine stable isotope analysis of chloroform using the Taguchi design of experiments
    Asfaw, Berhane Abrha
    Sakaguchi-Soeder, Kaori
    Bernstein, Anat
    Siebner, Hagar
    Schuth, Christoph
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (23)
  • [8] Analysis of Compound-Specific Chlorine Stable Isotopes of Vinyl Chloride by Continuous Flow-Isotope Ratio Mass Spectrometry (FC-IRMS)
    Shouakar-Stash, Orfan
    Frape, S. K.
    Aravena, R.
    Gargini, A.
    Pasini, M.
    Drimmie, R. J.
    ENVIRONMENTAL FORENSICS, 2009, 10 (04) : 299 - 306
  • [9] Tracking chlorinated contaminants in the subsurface using compound-specific chlorine isotope analysis: A review of principles, current challenges and applications
    Zimmermann, Jeremy
    Halloran, Landon J. S.
    Hunkeler, Daniel
    CHEMOSPHERE, 2020, 244 (244)
  • [10] Compound-specific nitrogen and carbon isotope analysis of nitroaromatic compounds in aqueous samples using solid-phase microextraction coupled to GC/IRMS
    Berg, Michael
    Bolotin, Jakov
    Hofstetter, Thomas B.
    ANALYTICAL CHEMISTRY, 2007, 79 (06) : 2386 - 2393