Variation of compound-specific hydrogen isotope ratios under changing temperature program in gas chromatography/thermal conversion/isotope ratio mass spectrometry

被引:9
|
作者
Liu, Weiguo [1 ,2 ]
Wang, Zheng [1 ]
Cui, Linlin [2 ]
Sauer, Peter E. [3 ]
Cao, Yunning [1 ]
机构
[1] Chinese Acad Sci, IEE, State Key Lab Loess & Quaternary Geol, Xian 710075, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Human Settlement & Civil Engn, Xian 710049, Peoples R China
[3] Indiana Univ, Dept Geol Sci, Bloomington, IN 47405 USA
基金
中国国家自然科学基金;
关键词
N-ALKANES; DELTA-D; TERRESTRIAL PLANTS; FRACTIONATION; PYROLYSIS; PRECISION; BIOMARKER; CLIMATE; RECORD;
D O I
10.1002/rcm.6283
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE In recent experiments, we found that compound-specific d2H values can vary as a result of changing the gas chromatography temperature program under common pyrolysis conditions. To achieve better precision, it is necessary to examine the details and find a solution to this problem when using gas chromatography/thermal conversion/isotope ratio mass spectrometry (GC-TC-IRMS) for hydrogen isotope analysis. METHODS A test was designed to find the possible temperature effect under four different GC temperature ramp rates using n-alkanes (n-C21, n-C27, and n-C31) and fatty acids (n-C12, n-C18, and n-C24). The common 'hexane' method was used initially to condition the pyrolysis reactor. Experiments were then carried out using the 'methane condition' method because it was considered to improve pyrolysis efficiency. RESULTS Under the 'hexane condition' the measured hydrogen isotope ratios of the n-alkanes and n-fatty acids became more positive with increasing GC temperature ramp rate. The ion current intensity of hydrogen also generally increased. However, when the 'methane condition' method was used, the measured d2H values of the n-alkanes and n-fatty acids showed little change under different GC temperature ramp rates. CONCLUSIONS Higher pyrolysis efficiency could reduce the tailing of the H2 peak and the related isotopic variations at increased GC temperature ramp rates. In addition, too slow a temperature ramp rate could broaden the peak width and thus increase the background effect and possible isotopic fractionations in the split interface; this could also influence the hydrogen isotope values. We therefore suggest that the appropriate temperature ramp rate is an important factor in improving the precision in analyzing compound-specific hydrogen isotopes. Copyright (C) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:1746 / 1752
页数:7
相关论文
共 50 条
  • [1] Compound-Specific Chlorine Isotope Analysis: A Comparison of Gas Chromatography/Isotope Ratio Mass Spectrometry and Gas Chromatography/Quadrupole Mass Spectrometry Methods in an Interlaboratory Study
    Bernstein, Anat
    Shouakar-Stash, Orfan
    Ebert, Karin
    Laskov, Christine
    Hunkeler, Daniel
    Jeannottat, Simon
    Sakaguchi-Soeder, Kaori
    Laaks, Jens
    Jochmann, Maik A.
    Cretnik, Stefan
    Jager, Johannes
    Haderlein, Stefan B.
    Schmidt, Torsten C.
    Aravena, Ramon
    Elsner, Martin
    [J]. ANALYTICAL CHEMISTRY, 2011, 83 (20) : 7624 - 7634
  • [2] Compound-specific bromine isotope ratio analysis using gas chromatography/quadrupole mass spectrometry
    Zakon, Yevgeni
    Halicz, Ludwik
    Lev, Ovadia
    Gelman, Faina
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (17) : 1951 - 1956
  • [3] Isotope effects associated with the preparation and methylation of fatty acids by boron trifluoride in methanol for compound-specific stable hydrogen isotope analysis via gas chromatography/thermal conversion/isotope ratio mass spectrometry
    Chivall, David
    Berstan, Robert
    Bull, Ian D.
    Evershed, Richard P.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (10) : 1232 - 1240
  • [4] Compound-specific stable carbon isotope analysis of hexabromocyclododecane diastereoisomers using gas chromatography/isotope ratio mass spectrometry
    Cheng, Gen
    Gao, Shutao
    Gao, Yang
    Yu, Zhiqiang
    Peng, Ping'an
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2019, 33 (16) : 1318 - 1323
  • [5] Compound-Specific Hydrogen Isotope Analysis of Heteroatom-Bearing Compounds via Gas Chromatography-Chromium-Based High-Temperature Conversion (Cr/HTC)-Isotope Ratio Mass Spectrometry
    Renpenning, Julian
    Kuemmel, Steffen
    Hitzfeld, Kristina L.
    Schimmelmann, Arndt
    Gehre, Matthias
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (18) : 9443 - 9450
  • [6] Isotope ratio monitoring gas chromatography mass spectrometry of D H by high temperature conversion isotope ratio mass spectrometry
    Hilkert, AW
    Douthitt, CB
    Schlüter, HJ
    Brand, WA
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (13) : 1226 - 1230
  • [7] Compound-specific stable carbon isotope analysis of galaxolide enantiomers in sediment using gas chromatography/isotope ratio monitoring mass spectrometry
    Wang, Jingzhi
    Gao, Shutao
    Zeng, Xiangying
    Yu, Zhiqiang
    Peng, Ping'an
    Sheng, Guoying
    Fu, Jiamo
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (15) : 1690 - 1696
  • [8] Memory Effects in Compound-Specific D/H Analysis by Gas Chromatography/Pyrolysis/Isotope-Ratio Mass Spectrometry
    Wang, Ying
    Sessions, Alex L.
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (23) : 9162 - 9170
  • [9] Derivatization of Levoglucosan for Compound-Specific δ13C Analysis by Gas Chromatography/Combustion/Isotope Ratio Mass Spectrometry
    Zhang, Dongling
    Swe Aung, Swe
    Han, Yong
    Zhang, Yanlin
    Chen, Yingjun
    Li, Hongli
    Yu, Feifei
    Wang, Yangjun
    Feng, Jialiang
    Wang, Wu
    [J]. INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 2020 (2020)
  • [10] Gas chromatography flow rates for determining deuterium/hydrogen ratios of natural gas by gas chromatography/high-temperature conversion/isotope ratio mass spectrometry
    Jia, Wanglu
    Peng, Ping'an
    Liu, Jinzhong