Computerised simulation of the energy consumption of air handling units

被引:12
|
作者
Kajtar, Laszlo [1 ]
Kassai, Miklos [1 ]
Banhidi, Laszlo [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Bldg Serv Engn & Proc Engn, H-1111 Budapest, Hungary
关键词
Energy consumption; Air handling unit; Computerised program;
D O I
10.1016/j.enbuild.2011.10.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
According to the 2002/91/EC, the Directive on the energy performance of buildings it is important to determine the expected energy consumption of the building in the step of the designing. There are imperfections in the actual available national and international regulations as for the methods to calculate the energy consumption of the air handling units. The actual calculation methods are fairly inexact approximations while they characterise the monthly energy consumption only with the average temperature or average enthalpy which takes into account the changing of the ambient air state only approximately. The most actual calculation procedures also not consider the systems that operate not continuously (only at night or in daytime). Based on the calculation procedure that uses the ambient temperature and enthalpy duration curves these problems can be solved. A new calculation method was worked out that takes into consideration the air handling energy consumption with the ambient temperature and enthalpy duration curves. To analyse the energy consumption of the air handling units fast and efficiently and to make energetic comparison of various constructed air handling units a computerised simulation PC program was made. The research work was supported by "Sustainable Energy Program" of BUTE Research University. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [31] Quality of Condensate From Air-Handling Units
    Glawe, Diana
    Wooten, Marilyn
    Lye, Dennis
    ASHRAE JOURNAL, 2016, 58 (12) : 14 - +
  • [32] Tracking controller design for air handling units with uncertainties
    Fang Shang
    Yongshuai Ji
    Wei Peng
    Jingdong Duan
    Yikai Yin
    Building Simulation, 2023, 16 : 547 - 556
  • [33] Tracking controller design for air handling units with uncertainties
    Shang, Fang
    Ji, Yongshuai
    Peng, Wei
    Duan, Jingdong
    Yin, Yikai
    BUILDING SIMULATION, 2023, 16 (04) : 547 - 556
  • [34] The Fate of Mengovirus on Fiberglass Filter of Air Handling Units
    Victor Bandaly
    Aurélie Joubert
    Pierre Le Cann
    Yves Andres
    Food and Environmental Virology, 2017, 9 : 464 - 472
  • [35] LOW FACE VELOCITY AIR HANDLING UNITS.
    Ritcher, James J.
    HPAC Heating, Piping, Air Conditioning, 1987, 59 (12): : 73 - 75
  • [36] The Fate of Mengovirus on Fiberglass Filter of Air Handling Units
    Bandaly, Victor
    Joubert, Aurelie
    Le Cann, Pierre
    Andres, Yves
    FOOD AND ENVIRONMENTAL VIROLOGY, 2017, 9 (04) : 464 - 472
  • [37] Commissioning air-handling units for economy and performance
    Wilkinson, Ronald J.
    HPAC Heating, Piping, AirConditioning Engineering, 2002, 74 (07): : 57 - 60
  • [38] Simulation of air infiltration of Australian housing and its impact on energy consumption
    Ren, Zhengen
    Chen, Dong
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2717 - 2723
  • [39] Forecasting the Energy Consumption of an Actual Air Handling Unit and Absorption Chiller Using ANN Models
    Kim, Jee-Heon
    Seong, Nam-Chul
    Choi, Wonchang
    ENERGIES, 2020, 13 (17)
  • [40] The effect of heat-pipe air-handling coil on energy consumption in central air-conditioning system
    Wan, J. W.
    Zhang, J. L.
    Zhang, W. M.
    ENERGY AND BUILDINGS, 2007, 39 (09) : 1035 - 1040