Computerised simulation of the energy consumption of air handling units

被引:12
|
作者
Kajtar, Laszlo [1 ]
Kassai, Miklos [1 ]
Banhidi, Laszlo [1 ]
机构
[1] Budapest Univ Technol & Econ, Dept Bldg Serv Engn & Proc Engn, H-1111 Budapest, Hungary
关键词
Energy consumption; Air handling unit; Computerised program;
D O I
10.1016/j.enbuild.2011.10.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
According to the 2002/91/EC, the Directive on the energy performance of buildings it is important to determine the expected energy consumption of the building in the step of the designing. There are imperfections in the actual available national and international regulations as for the methods to calculate the energy consumption of the air handling units. The actual calculation methods are fairly inexact approximations while they characterise the monthly energy consumption only with the average temperature or average enthalpy which takes into account the changing of the ambient air state only approximately. The most actual calculation procedures also not consider the systems that operate not continuously (only at night or in daytime). Based on the calculation procedure that uses the ambient temperature and enthalpy duration curves these problems can be solved. A new calculation method was worked out that takes into consideration the air handling energy consumption with the ambient temperature and enthalpy duration curves. To analyse the energy consumption of the air handling units fast and efficiently and to make energetic comparison of various constructed air handling units a computerised simulation PC program was made. The research work was supported by "Sustainable Energy Program" of BUTE Research University. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [21] Real heat recovery with air handling units
    Roulet, CA
    Heidt, FD
    Foradini, F
    Pibiri, MC
    ENERGY AND BUILDINGS, 2001, 33 (05) : 495 - 502
  • [22] Heating energy implications of utilizing gas-phase air cleaners in buildings? centralized air handling units
    Nourozi, Behrouz
    Holmberg, Sture
    Duwig, Christophe
    Afshari, Alireza
    Wargocki, Pawel
    Olesen, Bjarne
    Sadrizadeh, Sasan
    RESULTS IN ENGINEERING, 2022, 16
  • [23] Energy and Control Performance Investigation of Dual-Branch Air-Handling Units with Return Air Bypass
    Kiamehr, Koosha
    Wang, Gang
    ASHRAE TRANSACTIONS, VOL 124, PT 1, 2018, 124 : 137 - 147
  • [24] Fresh air fault diagnosis for mixed air in air-handling units
    Hou Zhi-jian
    Lian Zhi-wei
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2007, 14 : 436 - 438
  • [26] A Multi-Objective Approach to Robust Control of Air Handling Units for Optimized Energy Performance
    Wani, Mubashir
    Hafiz, Faizal
    Swain, Akshya
    Ukil, Abhisek
    ELECTRONICS, 2023, 12 (03)
  • [27] CASE STUDY OF ENERGY EFFICIENCY IN AIR HANDLING UNITS WITH HEAT EXCHANGERS FOR RESIDENTIAL APPLICATION IN LATVIA
    Plavenieks, Gatis
    Lesinskis, Arturs
    CIVIL ENGINEERING '13, PT I, 2013, 4 : 240 - 244
  • [28] Experimental investigation of a thermosyphon based heat exchanger used in energy efficient air handling units
    Jouhara, Hussam
    Merchant, Hasnain
    ENERGY, 2012, 39 (01) : 82 - 89
  • [29] Bacteria and fungi in two air handling units with air recirculating module
    Piekarska, Katarzyna
    Trusz, Agnieszka
    Szczesniak, Sylwia
    ENERGY AND BUILDINGS, 2018, 178 : 154 - 164
  • [30] Simulation Model for the Estimation of Energy Consumption of the Baggage Handling System in the Landside Area of the Airport
    Kierzkowski, Artur
    Kisiel, Tomasz
    ENERGIES, 2022, 15 (01)