Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system

被引:61
|
作者
Zhang, Ning [1 ]
Yin, Shao-You [2 ]
Zhang, Li-Zhi [1 ,3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Educ Minist, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510640, Guangdong, Peoples R China
[2] Shunde Polytech, Heat Pump Engn & Technol Dev Ctr Guangdong Univ, Foshan 528333, Peoples R China
[3] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
关键词
Heat pump; Hollow fiber membrane; Liquid desiccant; Two-stage; System performance; COOLING SYSTEM; MASS-TRANSFER; HVAC SYSTEMS; ENERGY; REGENERATION; OPTIMIZATION; TEMPERATURE; EXCHANGERS; SIMULATION; CHILLERS;
D O I
10.1016/j.apenergy.2016.07.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel compression heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system is presented. The liquid desiccant droplets are prevented from crossing over into the process air by the semi-permeable membranes. The isoenthalpic processes are changed to quasi isothermal processes by the two-stage dehumidification processes. The system is set up and a model is proposed for simulation. Heat and mass capacities in the system, including the membrane modules, the condenser, the evaporator and the heat exchangers are modeled in detail. The model is also validated experimentally. Compared with a single-stage dehumidification system, the two-stage system has a lower solution concentration exiting from the dehumidifier and a lower condensing temperature. Thus, a better thermodynamic system performance is realized and the COP can be increased by about 20% under the typical hot and humid conditions in Southern China. The allocations of heat and mass transfer areas in the system are also investigated. It is found that the optimal regeneration to dehumidification area ratio is 1.33. The optimal first to second stage dehumidification area ratio is 1.4; and the optimal first to second stage regeneration area ratio is 1.286. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 50 条
  • [21] Membrane-based packed-sheet liquid desiccant dehumidification system
    Elsafi, Amin M.
    Bahrami, Majid
    Bahrami, Majid (mbahrami@sfu.ca), 1600, Elsevier Ltd (236):
  • [22] Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system
    Xie, Ying
    Zhang, Tao
    Liu, Xiaohua
    ENERGY, 2016, 115 : 446 - 457
  • [23] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    ENERGY, 2020, 204
  • [24] Performance analysis of three-stage liquid desiccant deep dehumidification processor driven by heat pump
    Zhang, Haiqiang
    Liu, Xiaohua
    Jiang, Yi
    Journal of Southeast University (English Edition), 2010, 26 (02) : 217 - 221
  • [25] Heat and mass transfer deteriorations in an elliptical hollow fiber membrane tube bank for liquid desiccant air dehumidification
    Huang, Si-Min
    Qin, Frank G. F.
    Yang, Minlin
    Yang, Xiaoxi
    Zhong, Wen-Feng
    APPLIED THERMAL ENGINEERING, 2013, 57 (1-2) : 90 - 98
  • [26] Turbulent Heat and Mass Transfer Across a Hollow Fiber Membrane Tube Bank in Liquid Desiccant Air Dehumidification
    Huang, Si-Min
    Zhang, Li-Zhi
    Tang, Kai
    Pei, Li-Xia
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (08):
  • [27] The design and experimental investigation of membrane-based tubular liquid desiccant dehumidification system
    Kavasogullari, Baris
    Cihan, Ertugrul
    Demir, Hasan
    PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2023, 29 (04): : 303 - 313
  • [28] Thermodynamic Dynamic Characteristics of the Internally-cooled Membrane-based Liquid Desiccant Air Dehumidification System
    Yang, Yu
    Yan, Jun-Wei
    Zhou, Xuan
    Xiao, Lie-Hui
    Huang, Si-Min
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (08): : 1944 - 1949
  • [29] Study on performance and liquid film distribution of a two-stage evaporator for heating and dehumidification integrated heat pump
    Du, Anran
    Long, Jibo
    Zhang, Ruichao
    Lu, Jiao
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (05) : 6816 - 6830
  • [30] Performance characterization of a novel membrane-based liquid desiccant air conditioning system
    Gurubalan, A.
    Maiya, M. P.
    Tiwari, Shaligram
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 120 : 445 - 459