Effects of bileaflet mechanical heart valve orientation on fluid stresses and coronary flow

被引:16
|
作者
Haya, Laura [1 ]
Tavoularis, Stavros [1 ]
机构
[1] Univ Ottawa, Dept Mech Engn, Ottawa, ON K1N 6N5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
biological fluid dynamics; blood flow; PARTICLE IMAGE VELOCIMETRY; FREE EMBOLI FORMATION; AORTIC-VALVE; SHEAR-STRESS; ARTERY FLOW; DOWNSTREAM; TURBULENCE; FIELD; PIV;
D O I
10.1017/jfm.2016.582
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The effects of the orientation of a bileaflet mechanical heart valve on the viscous and turbulent stresses in the flow past it and on the flow rate in the right coronary artery were investigated in vitro in a mock circulation loop, using a fluid that matched the kinematic viscosity of blood and the refractive index of the aorta model. Measurements were made past the valve mounted in three orientations at the base of an anatomical aorta model, within physiological aortic flow conditions. At peak flow, the turbulent stresses were on average 21% higher and viscous stresses exceeding 10 Pa (namely of a level that has been associated with blood cell damage) were 30% more frequent when the valve was oriented with its plane of symmetry normal to the aorta's plane of curvature than when it was parallel to it. This was attributed to the impingement of a lateral jet on the concave wall of the aorta and to steeper velocity gradients resulting from the geometrical imbalance of the sinuses relative to the valve's central jet when the valve was in the 'normal' orientation. Very high levels of turbulent stresses were found to occur distal to the corners of the valve's lateral orifices. The bulk flow rate in the right coronary artery was highest when the valve was positioned with its central orifice aligned with the artery's opening. The coronary flow rate was directly affected by the size, orientation and time evolution of the vortex in the sinus, all of which were sensitive to the valve's orientation.
引用
收藏
页码:129 / 164
页数:36
相关论文
共 50 条
  • [21] Numerical investigation on effect of aortic root geometry on flow induced structural stresses developed in a bileaflet mechanical heart valve
    Abbas, S. S.
    Nasif, M. S.
    Said, M. A. M.
    Kadhim, S. K.
    INTERNATIONAL CONFERENCE ON APPLICATIONS AND DESIGN IN MECHANICAL ENGINEERING (ICADME 2017), 2017, 908
  • [22] Validation of a fluid-structure interaction model for a bileaflet mechanical heart valve
    Forsythe, Neil
    Mueller, Jens-Dominik
    INTERNATIONAL JOURNAL OF COMPUTATIONAL FLUID DYNAMICS, 2008, 22 (08) : 541 - 553
  • [23] Three-Dimensional Fluid-Structure Interaction Simulation of Bileaflet Mechanical Heart Valve Flow Dynamics
    Rui Cheng
    Yong G. Lai
    Krishnan B. Chandran
    Annals of Biomedical Engineering, 2004, 32 : 1471 - 1483
  • [24] Three-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics
    Cheng, R
    Lai, YG
    Chandran, KB
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (11) : 1471 - 1483
  • [25] The Effect of Implantation Orientation of a Bileaflet Mechanical Heart Valve on Kinematics and Hemodynamics in an Anatomic Aorta
    Borazjani, Iman
    Sotiropoulos, Fotis
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (11):
  • [26] Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics
    Cheng, R
    Lai, YG
    Chandran, KB
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (06): : 772 - 780
  • [27] A SQUEEZE FLOW PHENOMENON AT THE CLOSING OF A BILEAFLET MECHANICAL HEART-VALVE PROSTHESIS
    BLUESTEIN, D
    EINAV, S
    HWANG, NHC
    JOURNAL OF BIOMECHANICS, 1994, 27 (11) : 1369 - 1378
  • [28] Computational fluid dynamics study of a protruded-hinge bileaflet mechanical heart valve
    Wang, JH
    Yao, H
    Lim, CJ
    Zhao, Y
    Yeo, TJH
    Hwang, NHC
    JOURNAL OF HEART VALVE DISEASE, 2001, 10 (02): : 254 - 262
  • [29] Three-dimensional fluid mechanics of the sinus of Valsalva with a bileaflet mechanical heart valve
    Yagi, Takanobu
    Ishikawa, Daisuke
    Sudo, Hiroyuki
    Wakasa, Shotaro
    Yang, William
    Iwasaki, Kiyotaka
    Umezu, Mitsuo
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 187 - 188
  • [30] Impact of Bileaflet Mechanical Mitral Valve Orientation on Pannus Overgrowth
    Duman, Zihni Mert
    Apaydin, Zinar
    Can, Isa
    Kaplan, Mustafa Can
    Bugra, Abduel Kerim
    Timur, Baris
    Bayram, Muhammed
    Karakurt, Seda Tukenmez
    Guler, Gamze Babur
    Kadirogullari, Ersin
    Onan, Burak
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2023, 18 (05) : 466 - 471