Effects of bileaflet mechanical heart valve orientation on fluid stresses and coronary flow

被引:16
|
作者
Haya, Laura [1 ]
Tavoularis, Stavros [1 ]
机构
[1] Univ Ottawa, Dept Mech Engn, Ottawa, ON K1N 6N5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
biological fluid dynamics; blood flow; PARTICLE IMAGE VELOCIMETRY; FREE EMBOLI FORMATION; AORTIC-VALVE; SHEAR-STRESS; ARTERY FLOW; DOWNSTREAM; TURBULENCE; FIELD; PIV;
D O I
10.1017/jfm.2016.582
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The effects of the orientation of a bileaflet mechanical heart valve on the viscous and turbulent stresses in the flow past it and on the flow rate in the right coronary artery were investigated in vitro in a mock circulation loop, using a fluid that matched the kinematic viscosity of blood and the refractive index of the aorta model. Measurements were made past the valve mounted in three orientations at the base of an anatomical aorta model, within physiological aortic flow conditions. At peak flow, the turbulent stresses were on average 21% higher and viscous stresses exceeding 10 Pa (namely of a level that has been associated with blood cell damage) were 30% more frequent when the valve was oriented with its plane of symmetry normal to the aorta's plane of curvature than when it was parallel to it. This was attributed to the impingement of a lateral jet on the concave wall of the aorta and to steeper velocity gradients resulting from the geometrical imbalance of the sinuses relative to the valve's central jet when the valve was in the 'normal' orientation. Very high levels of turbulent stresses were found to occur distal to the corners of the valve's lateral orifices. The bulk flow rate in the right coronary artery was highest when the valve was positioned with its central orifice aligned with the artery's opening. The coronary flow rate was directly affected by the size, orientation and time evolution of the vortex in the sinus, all of which were sensitive to the valve's orientation.
引用
收藏
页码:129 / 164
页数:36
相关论文
共 50 条
  • [1] Swirling Flow in Bileaflet Mechanical Heart Valve
    Gataulin, Yakov A.
    Khorobrov, Svyatoslav V.
    Yukhnev, Andrey D.
    EIGHTH POLYAKHOV'S READING, 2018, 1959
  • [2] Effects of pannus formation on the flow around a bileaflet mechanical heart valve
    Kim, Woojin
    Choi, Haecheon
    Kweon, Jihoon
    Yang, Dong Hyun
    Kim, Young-Hak
    PLOS ONE, 2020, 15 (06):
  • [3] Computational fluid dynamics simulation of blood flow profile and shear stresses in bileaflet mechanical heart valve by using monolithic approach
    Kadhim, Saleem Khalefa
    Nasif, Mohammad Shakir
    Al-Kayiem, Hussain H.
    Al-Waked, Rafat
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2018, 94 (02): : 93 - 104
  • [4] A Fluid Structure Interaction Model of Bileaflet and Monoleaflet Mechanical Heart Valve Flow Dynamics
    Kimiaghalam, Morteza
    Rubenstein, David Alan
    Yin, Wei
    FASEB JOURNAL, 2013, 27
  • [5] Hinge flow in a bileaflet mechanical heart valve (MHV)
    Yeo, Joon Hock
    Yao, Hai
    Wang, Junhong
    Hwang, Ned H.C.
    ASAIO Journal, 2000, 46 (02)
  • [6] Impact of superhydrophobicity on the fluid dynamics of a bileaflet mechanical heart valve
    Hatoum, Hoda
    Vallabhuneni, Sravanthi
    Kota, Arun Kumar
    Bark, David L.
    Popat, Ketul C.
    Dasi, Lakshmi Prasad
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2020, 110
  • [7] Impact of superhydrophobicity on the fluid dynamics of a bileaflet mechanical heart valve
    Hatoum, Hoda
    Vallabhuneni, Sravanthi
    Kota, Arun Kumar
    Bark, David L.
    Popat, Ketul C.
    Dasi, Lakshmi Prasad
    Journal of the Mechanical Behavior of Biomedical Materials, 2020, 110
  • [8] Experimental investigation of flow through a bileaflet mechanical heart valve
    Mejia, J.
    Oshkai, P.
    ADVANCES IN FLUID MECHANICS VI, 2006, 52 : 593 - +
  • [9] Passive flow control of bileaflet mechanical heart valve leakage flow
    Dasi, Lakshmi P.
    Murphy, David W.
    Glezer, An
    Yoganathan, Ajit P.
    JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1166 - 1173
  • [10] The effects of the tilt angle of a bileaflet mechanical heart valve on blood flow and leaflet motion
    Kim, Chang Nyung
    Hong, Taehyup
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (03) : 819 - 825