Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy

被引:7
|
作者
Kim, Sung Hun [1 ]
Jeong, Jong Hwi [1 ]
Ku, Youngmo [2 ]
Jung, Jaerin [2 ]
Cho, Sungkoo [3 ]
Jo, Kwanghyun [3 ]
Kim, Chan Hyeong [2 ]
机构
[1] Natl Canc Ctr, Ctr Proton Therapy, Goyang Si 10408, Gyeonggi Do, South Korea
[2] Hanyang Univ, Dept Nucl Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[3] Samsung Med Ctr, Radiat Oncol, Seoul 06351, South Korea
关键词
Prompt gamma imaging; Gamma electron vertex imaging; In-vivo range verification; Pencil beam scanning proton therapy; Proton therapy;
D O I
10.1016/j.net.2021.09.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In proton therapy, a highly conformal proton dose can be delivered to the tumor by means of the steep distal dose penumbra at the end of the beam range. The proton beam range, however, is highly sensitive to range uncertainty, which makes accurately locating the proton range in the patient difficult. In-vivo range verification is a method to manage range uncertainty, one of the promising techniques being prompt gamma imaging (PGI). In earlier studies, we proposed gamma electron vertex imaging (GEVI), and constructed a proof-of-principle system. The system successfully demonstrated the GEVI imaging principle for therapeutic proton pencil beams without scanning, but showed some limitations under clinical conditions, particularly for pencil beam scanning proton therapy. In the present study, we upgraded the GEVI system in several aspects and tested the performance improvements such as for range-shift verification in the context of line scanning proton treatment. Specifically, the system showed better performance in obtaining accurate prompt gamma (PG) distributions in the clinical environment. Furthermore, high shift-detection sensitivity and accuracy were shown under various range-shift conditions using line scanning proton beams. (c) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1016 / 1023
页数:8
相关论文
共 50 条
  • [21] Prompt Gamma Imaging of a Pencil Beam with a High Efficiency Compton Camera at a Clinical Proton Therapy Facility
    Hueso-Gonzalez, F.
    Petzoldt, J.
    Roemer, K. E.
    Schoene, S.
    Fiedler, F.
    Golnik, C.
    Kormoll, T.
    Pausch, G.
    Enghardt, W.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [22] Effective Treatment Plan Integrity Verification for Passive Scattering and Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Ho, M.
    Liu, C.
    Liang, X.
    Johnson, P.
    Park, J.
    Artz, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [23] Comparison of Prompt Gamma and PET Imaging for Range Verification in Proton Therapy
    Moteabbed, M.
    Espana, S.
    Paganetti, H.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] Development and Evaluation of a Pixel Detector System for Pencil Beam Scanning Proton Therapy
    Eichin, Michael
    Actis, O.
    Grossmann, M.
    Konig, S.
    Mayor, A.
    Meer, D.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (07) : 1273 - 1279
  • [25] Predictive Models for Cone Beam CT-Based Online Verification of Pencil Beam Scanning Proton Therapy
    Yin, L.
    Janssens, G.
    Lin, A.
    Ahn, P.
    Solberg, T.
    McDonough, J.
    Teo, B.
    MEDICAL PHYSICS, 2016, 43 (06) : 3454 - 3454
  • [26] 3D prompt gamma imaging for proton beam range verification
    Draeger, E.
    Mackin, D.
    Peterson, S.
    Chen, H.
    Avery, S.
    Beddar, S.
    Polf, J. C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03):
  • [27] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Zhang, Y.
    Liu, C.
    Ho, M.
    Park, J.
    Hsi, W.
    Liang, X.
    Li, Z.
    Song, Y.
    Feng, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [28] Fast MCsquare-Based Independent Dose Verification Platform for Pencil Beam Scanning Proton Therapy
    Liu, Chunbo
    Ho, Meng Wei
    Park, Jiyeon
    Hsi, Wen Chien
    Liang, Xiaoying
    Li, Zuofeng
    Song, Yuntao
    Feng, Hansheng
    Zhang, Yawei
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [29] Integration and Testing of Dynamic Collimation System Controller for Pencil Beam Scanning Proton Therapy
    Patwardhan, K.
    Geoghegan, T.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E800 - E800
  • [30] Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Gutierrez, Alonso N.
    Boland, Thibault
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)