Appropriate and inappropriate implantable cardioverter defibrillator interventions during secondary prevention

被引:7
|
作者
Van der Velden, Lieven B. J. [1 ]
Huybrechts, Wim [1 ]
Adriaensens, Bert [1 ]
Ector, Joris [1 ]
Ector, Hugo [1 ]
Willems, Rik [1 ]
Heidbuechel, Hein [1 ]
机构
[1] Univ Hosp Leuven, Dept Cardiol, B-3000 Louvain, Belgium
关键词
implantable cardioverter defibrillator; sudden death; ventricular arrhythmias; appropriate; inappropriate; interventions;
D O I
10.2143/AC.63.1.2025330
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - ICD therapy is established therapy for secondary prevention after aborted sudden death or ventricular tachycardia. Long-term data on the incidence of appropriate and inappropriate interventions are scarce. Methods and results -We retrospectively studied 391 patients with an ICD for secondary prophylaxis: 247 (63%) with ischaemic heart disease (IHD) and 144 without IHD (37%). Fifty-four patients were free from left ventricular structural disease. Mean follow-up was 30.8 months. Kaplan-Meier methodology was used for survival analysis. The use of beta-blockers was high and similar in both groups (85% IHD; 88% non-IHD; P = 0.36). The incidence of appropriate interventions was identical in IHD and non-IHD (42.7% and 47.8% at 4y; HR 1.0, P = 0.99).There was a yearly rate of first intervention around 5% even in the fourth and fifth year after implantation. The incidence of inappropriate interventions was about half that of appropriate ICD interventions (21.4% at 4 y). It was higher in patients who also had received appropriate therapy (HR: 2.73 in the IHD group, 1.61 in the non-IHD group, P < 0.001 for both). Atrial fibrillation was the most common cause of inappropriate interventions in IHD, and sinus tachycardia in those without LV disease.The incidence of inappropriate interventions was not dependent on the type of ICD (VVI vs. DDD), in any group. Conclusions - Patients with an ICD for secondary prophylaxis have a high rate of appropriate interventions, and remain at risk for developing a first intervention several years after implantation. Inappropriate interventions constitute a significant burden.Taking preventive measures (AV nodal slowing drugs, device selection and programming, patient counseling regarding allowable physical activity) is required to optimize the quality-of-life adjusted life-saving potential of ICDs.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [41] Impact of Implantable Cardioverter-Defibrillator Therapy on a Secondary Prevention Population Reply
    Borne, Ryan T.
    Varosy, Paul D.
    Masoudi, Frederick A.
    JAMA INTERNAL MEDICINE, 2013, 173 (22) : 2094 - 2094
  • [42] Comments on: "Secondary prevention implantable cardioverter–defibrillator (ICD) therapy: value in octogenarians"
    Joshua Aaron Wren
    Aging Clinical and Experimental Research, 2022, 34 : 3159 - 3160
  • [43] Natural history of hemodialysis patients receiving an implantable cardioverter defibrillator for secondary prevention
    Dobesh, DP
    Stein, K
    Mittal, S
    Iwai, S
    Shah, B
    Cheung, J
    Tan, V
    Nemirovsky, D
    Dhruvakumar, S
    Lerman, B
    Markowitz, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 15A - 15A
  • [44] Comparison and predictors of implantable cardioverter-defibrillator therapy for primary and secondary prevention
    Evertz, Reinder
    van der Heijden, Tessa
    Beukema, Rypko
    Westra, Sjoerd
    Meindersma, Esther
    van Deursen, Caroline
    Vernooy, Kevin
    NETHERLANDS HEART JOURNAL, 2023, 31 (09) : 348 - 356
  • [45] Secondary prevention of sudden arrhythmic death: The role of the implantable cardioverter-defibrillator
    Esperer H.D.
    Klein H.
    Herzschrittmachertherapie und Elektrophysiologie, 2001, 12 (1): : 34 - 38
  • [46] Efficacy and Safety of Celivarone, With Amiodarone as Calibrator, in Patients With an Implantable Cardioverter-Defibrillator for Prevention of Implantable Cardioverter-Defibrillator Interventions or Death The ALPHEE Study
    Kowey, Peter R.
    Crijns, Harry J. G. M.
    Aliot, Etienne M.
    Capucci, Alessandro
    Kulakowski, Piotr
    Radzik, David
    Roy, Denis
    Connolly, Stuart J.
    Hohnloser, Stefan H.
    CIRCULATION, 2011, 124 (24) : 2649 - U204
  • [47] INAPPROPRIATE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCKS SECONDARY TO SENSING LEAD FAILURE - UTILITY OF STORED ELECTROGRAMS
    ALMEIDA, HF
    BUCKINGHAM, TA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03): : 407 - 411
  • [48] Latest data from secondary prevention implantable cardioverter-defibrillator trials
    Naccarelli, G
    Oseroff, O
    CLINICAL CARDIAC PACING AND ELECTROPHYSIOLOGY, 2003, : 965 - 973
  • [49] Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks
    Tzeis, Stylianos
    Andrikopoulos, George
    Kolb, Christof
    Vardas, Panos E.
    EUROPACE, 2008, 10 (11): : 1256 - 1265
  • [50] Inappropriate sensing of pectoral myopotentials by an implantable cardioverter defibrillator system
    Karanam, S
    John, RM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (05): : 688 - 689