Appropriate and inappropriate implantable cardioverter defibrillator interventions during secondary prevention

被引:7
|
作者
Van der Velden, Lieven B. J. [1 ]
Huybrechts, Wim [1 ]
Adriaensens, Bert [1 ]
Ector, Joris [1 ]
Ector, Hugo [1 ]
Willems, Rik [1 ]
Heidbuechel, Hein [1 ]
机构
[1] Univ Hosp Leuven, Dept Cardiol, B-3000 Louvain, Belgium
关键词
implantable cardioverter defibrillator; sudden death; ventricular arrhythmias; appropriate; inappropriate; interventions;
D O I
10.2143/AC.63.1.2025330
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - ICD therapy is established therapy for secondary prevention after aborted sudden death or ventricular tachycardia. Long-term data on the incidence of appropriate and inappropriate interventions are scarce. Methods and results -We retrospectively studied 391 patients with an ICD for secondary prophylaxis: 247 (63%) with ischaemic heart disease (IHD) and 144 without IHD (37%). Fifty-four patients were free from left ventricular structural disease. Mean follow-up was 30.8 months. Kaplan-Meier methodology was used for survival analysis. The use of beta-blockers was high and similar in both groups (85% IHD; 88% non-IHD; P = 0.36). The incidence of appropriate interventions was identical in IHD and non-IHD (42.7% and 47.8% at 4y; HR 1.0, P = 0.99).There was a yearly rate of first intervention around 5% even in the fourth and fifth year after implantation. The incidence of inappropriate interventions was about half that of appropriate ICD interventions (21.4% at 4 y). It was higher in patients who also had received appropriate therapy (HR: 2.73 in the IHD group, 1.61 in the non-IHD group, P < 0.001 for both). Atrial fibrillation was the most common cause of inappropriate interventions in IHD, and sinus tachycardia in those without LV disease.The incidence of inappropriate interventions was not dependent on the type of ICD (VVI vs. DDD), in any group. Conclusions - Patients with an ICD for secondary prophylaxis have a high rate of appropriate interventions, and remain at risk for developing a first intervention several years after implantation. Inappropriate interventions constitute a significant burden.Taking preventive measures (AV nodal slowing drugs, device selection and programming, patient counseling regarding allowable physical activity) is required to optimize the quality-of-life adjusted life-saving potential of ICDs.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [21] Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation
    Farwell, David
    Redpath, Calum
    Birnie, David
    Gollob, Michael
    Lemery, Robert
    Posan, Emoke
    Green, Martin
    EUROPACE, 2008, 10 (06): : 726 - 728
  • [22] Incidence of Appropriate and Inappropriate Shocks in Implantable Cardioverter-Defibrillator Patients With Obstructive Sleep Apnea
    Naksuk, Niyada
    Selcuk, Adabag
    JOURNAL OF CARDIAC FAILURE, 2012, 18 (08) : S54 - S54
  • [23] Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
    Connolly, SJ
    Hallstrom, AP
    Cappato, R
    Schron, EB
    Kuck, KH
    Zipes, DP
    Greene, HL
    Boczor, S
    Domanski, M
    Follmann, D
    Gent, M
    Roberts, RS
    EUROPEAN HEART JOURNAL, 2000, 21 (24) : 2071 - 2078
  • [24] Disparities in the implantation of secondary prevention implantable cardioverter defibrillator in the United States
    Maraey, Ahmed
    Yazdi, Vahid
    Chaaban, Nourhan
    Aglan, Amro
    Elzanaty, Ahmed
    Moustafa, Abdelmoniem
    Karim, Saima
    He, Beixin Julie
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (09): : 1241 - 1251
  • [25] Impact of Implantable Cardioverter-Defibrillator Therapy on a Secondary Prevention Population
    Rathod, Ankit
    Badheka, Apurva
    Deshmukh, Abhishek
    JAMA INTERNAL MEDICINE, 2013, 173 (22) : 2093 - 2094
  • [26] Tactics for the Reduction of Inappropriate Implantable Cardioverter Defibrillator Shocks
    Okuyama, Yuji
    CIRCULATION JOURNAL, 2010, 74 (07) : 1290 - 1291
  • [27] Inappropriate tachycardia detection by a biventricular Implantable cardioverter defibrillator
    Garcia-Moran, E
    Mont, L
    Brugada, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01): : 123 - 124
  • [28] PREDICTORS OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR DISCHARGES
    Catanzaro, John N.
    Makaryus, Amgad
    Makaryus, John
    Sison, Cristina
    Vavasis, Christos
    Donaldson, David
    Altman, Erik
    Beldner, Stuart
    Jadonath, Ram
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E172 - E172
  • [29] INAPPROPRIATE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCKS INCREASE MORTALITY
    Van Rees, Johannes B.
    Borleffs, C. Jan Willem
    de Bie, Mihaly K.
    Stijnen, Theo
    van Erven, Lieselot
    Bax, Jeroen J.
    Schalij, Martin J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [30] Inappropriate discharges of an implantable cardioverter defibrillator secondary to automatic adjustable gain of atrial tachycardia
    Schechter, SO
    Greenberg, SM
    Hoch, DH
    Cesa, M
    Levine, JH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (06): : 1721 - 1722