MEASUREMENT OF WATER CONTENT DISTRIBUTION IN CATALYST COATED MEMBRANE AT WATER PERMEATION CONDITION BY MAGNETIC RESONANCE IMAGING

被引:0
|
作者
Suzuki, Takahiro [1 ]
Tabuchi, Yuichiro [1 ]
Tsushima, Shohji
Hirai, Shuichiro
Aotani, Koichiro
Kubo, Norio
机构
[1] Tokyo Inst Technol, Dept Mech & Control Engn, Tokyo, Japan
关键词
POLYMER ELECTROLYTE MEMBRANE; FUEL-CELLS; TRANSPORT; DESORPTION; DIFFUSION;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Through-plane water content distribution in a polymer electrolyte membrane (PEM) and water flux across the membrane were measured under different water permeation conditions using magnetic resonance imaging (MRI) and a dew point measurement system. We placed the PEM by itself or as a catalyst coated membrane (CCM) in an experimental cell, and we subjected them to several water permeation conditions that had different water activities across the membrane. We compared the water content distribution and water flux of samples, and the results showed the membranes exhibited different water content distribution between the PEM and the CCM. The differences suggest that the rate-determining process of the water transport phenomena across the membrane, which are diffusion through the membrane and interfacial transport across the membrane-gas interface, changed according to whether the membrane is used by itself or as a CCM.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 50 条
  • [31] Reproducibility of In Vivo Magnetic Resonance Imaging-Based Measurement of Myelin Water
    Levesque, Ives R.
    Chia, Charmaine L. L.
    Pike, G. Bruce
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) : 60 - 68
  • [32] NONINVASIVE MEASUREMENT OF LIPID AND WATER IN FOOD USING MAGNETIC-RESONANCE-IMAGING
    WINKLER, M
    MCCARTHY, MJ
    GERMAN, JB
    JOURNAL OF FOOD SCIENCE, 1991, 56 (03) : 811 - 815
  • [33] An absolute measurement of brain water content using magnetic resonance imaging in two focal cerebral ischemic rat models
    Lin, WL
    Venkatesan, R
    Gurleyik, K
    He, YY
    Powers, WJ
    Hsu, CY
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2000, 20 (01): : 37 - 44
  • [34] Application of Terahertz Imaging to Water Content Measurement
    Zhang, Hong Bing
    Mitobe, Kazutaka
    Yoshimura, Noboru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (10) : 8065 - 8070
  • [35] Characterization of water distribution in bread during storage using magnetic resonance imaging
    Lodi, Alessia
    Abduljalil, Amir M.
    Vodovotz, Yael
    MAGNETIC RESONANCE IMAGING, 2007, 25 (10) : 1449 - 1458
  • [36] The effect of water content of articular cartilage on low-field magnetic resonance imaging
    Abd Latif, Mohd Juzaila
    Chin, Tan Kae
    Mokhtar, Nur Hazwani
    PROCEEDINGS OF MECHANICAL ENGINEERING RESEARCH DAY 2019 (MERD'19), 2019, : 93 - 94
  • [37] Magnetic resonance imaging of brain cell water
    Watanabe, Takashi
    Wang, Xiaoqing
    Tan, Zhengguo
    Frahm, Jens
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [38] Magnetic resonance imaging of brain cell water
    Takashi Watanabe
    Xiaoqing Wang
    Zhengguo Tan
    Jens Frahm
    Scientific Reports, 9
  • [39] MEASUREMENT OF FAT DISTRIBUTION BY MAGNETIC-RESONANCE IMAGING
    STATEN, MA
    TOTTY, WG
    KOHRT, WM
    INVESTIGATIVE RADIOLOGY, 1989, 24 (05) : 345 - 349
  • [40] Evolution of distribution and content of water in cement paste by low field nuclear magnetic resonance
    She An-ming
    Yao Wu
    Yuan Wan-cheng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2013, 20 (04) : 1109 - 1114