MEASUREMENT OF WATER CONTENT DISTRIBUTION IN CATALYST COATED MEMBRANE AT WATER PERMEATION CONDITION BY MAGNETIC RESONANCE IMAGING

被引:0
|
作者
Suzuki, Takahiro [1 ]
Tabuchi, Yuichiro [1 ]
Tsushima, Shohji
Hirai, Shuichiro
Aotani, Koichiro
Kubo, Norio
机构
[1] Tokyo Inst Technol, Dept Mech & Control Engn, Tokyo, Japan
关键词
POLYMER ELECTROLYTE MEMBRANE; FUEL-CELLS; TRANSPORT; DESORPTION; DIFFUSION;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Through-plane water content distribution in a polymer electrolyte membrane (PEM) and water flux across the membrane were measured under different water permeation conditions using magnetic resonance imaging (MRI) and a dew point measurement system. We placed the PEM by itself or as a catalyst coated membrane (CCM) in an experimental cell, and we subjected them to several water permeation conditions that had different water activities across the membrane. We compared the water content distribution and water flux of samples, and the results showed the membranes exhibited different water content distribution between the PEM and the CCM. The differences suggest that the rate-determining process of the water transport phenomena across the membrane, which are diffusion through the membrane and interfacial transport across the membrane-gas interface, changed according to whether the membrane is used by itself or as a CCM.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 50 条
  • [21] Magnetic Resonance Imaging and Relaxometry as Tools to Investigate Water Distribution in Soils
    Faure, Pamela F.
    Michel, Eric
    Sammartino, Stephane
    Doussan, Claude
    MAGNETIC RESONANCE IN POROUS MEDIA, 2011, 1330 : 69 - +
  • [22] Fat and Water Magnetic Resonance Imaging
    Bley, Thorsten A.
    Wieben, Oliver
    Francois, Christopher J.
    Brittain, Jean H.
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 4 - 18
  • [23] Magnetic resonance imaging observation of changes in water content during the drying and water absorption processes of a soil
    Tanaka, M
    Kamei, T
    Ando, Y
    PROCEEDINGS OF THE FIFTEENTH (2005) INTERNATIONAL OFFSHORE AND POLAR ENGINEERING CONFERENCE, VOL 2, 2005, : 436 - 441
  • [24] INVESTIGATION OF WATER CONDITION IN PERFLUORINATED CATION MEMBRANE BY THE PROTON MAGNETIC-RESONANCE METHOD
    KHUTSISHVILI, VG
    BOGACHEV, YS
    VOLKOV, VI
    TARASOVA, BV
    DREIMAN, NA
    SHAPETKO, NN
    TIMASHEV, SF
    ZHURNAL FIZICHESKOI KHIMII, 1984, 58 (10): : 2633 - 2633
  • [25] Magnetic resonance imaging (MRI) study of the water content and transport in rat lenses
    Dobretsov, Egor A.
    Snytnikova, Olga A.
    Koptyug, Igor V.
    Kaptein, Robert
    Tsentalovich, Yuri P.
    EXPERIMENTAL EYE RESEARCH, 2013, 113 : 162 - 171
  • [26] DETERMINATION OF LUNG WATER-CONTENT AND DISTRIBUTION BY NUCLEAR MAGNETIC-RESONANCE
    CUTILLO, AG
    MORRIS, AH
    BLATTER, DD
    CASE, TA
    AILION, DC
    DURNEY, CH
    JOHNSON, SA
    JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (02) : 583 - 588
  • [27] Enhanced water uptake in the longitudinal direction by shiitake mycelium in shiitake cultivation logs: water content distribution in logs measured by magnetic resonance imaging
    Ogawa, Kuniyasu
    Yashima, Takeshi
    WOOD SCIENCE AND TECHNOLOGY, 2022, 56 (01) : 25 - 62
  • [28] Enhanced water uptake in the longitudinal direction by shiitake mycelium in shiitake cultivation logs: water content distribution in logs measured by magnetic resonance imaging
    Kuniyasu Ogawa
    Takeshi Yashima
    Wood Science and Technology, 2022, 56 : 25 - 62
  • [29] Magnetic Resonance Imaging of Water in Operating Polymer Electrolyte Membrane Fuel Cells
    Tsushima, S.
    Hirai, S.
    FUEL CELLS, 2009, 9 (05) : 506 - +
  • [30] Imaging wavelength and light penetration depth for water content distribution measurement of skin
    Arimoto, H.
    Egawa, M.