Solid-phase microextraction of phthalate esters in water sample using different activated carbon-polymer monoliths as adsorbents

被引:43
|
作者
Lirio, Stephen [1 ]
Fu, Chung-Wei [1 ]
Lin, Jhih-Yun [1 ]
Hsu, Meng-Ju [1 ]
Huang, Hsi-Ya [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, 200 Chung Pei Rd, Taoyuan 320, Taiwan
关键词
Phthalate ester; Poly(styrene-divinylbenzene); Activated carbon; Polymer monolith; Solid-phase microextraction; CHROMATOGRAPHY MASS-SPECTROMETRY; PI-PI-INTERACTIONS; GAS-CHROMATOGRAPHY; RIVER WATER; FIBER; EXTRACTION; COLUMNS; OXIDE; CONTAMINATION; ENRICHMENT;
D O I
10.1016/j.aca.2016.05.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the application of different activated carbon-polymer (AC-polymer) monoliths as adsorbents for the solid-phase microextraction (SPME) of phthalate esters (PAEs) in water sample were investigated. The activated carbon (AC) was embedded in organic polymers, poly(butyl methacrylate-co-ethylene dimethacrylate) (poly(BMA-EDMA)) or poly(styrene-co-divinylbenzene) (poly(STY-DVB)), via a 5-min microwave-assisted or a 15-min water bath heating polymerization. Preliminary investigation on the performance of the native poly(BMA-EDMA) and poly(STY-DVB) demonstrated remarkable adsorption efficiencies for PAEs. However, due to the strong hydrophobic, pi-pi, and hydrogen bonding interactions between the analytes and polymers, low extraction recoveries were achieved. In contrast, the presence of AC in native polymers not only enhanced the adsorption efficiencies but also assisted the PAE desorption, especially for AC-poly(STY-DVB) with extraction recovery ranged of 76.2-99.3%. Under the optimized conditions, the extraction recoveries for intra-, inter-day and column-to-column were in the range of 76.5-100.8% (<3.7% RSDs), 77.2-97.6% (<5.6% RSDs) and 75.5-99.7% (<6.2% RSDs), respectively. The developed AC-poly(STY-DVB) monolithic column showed good mechanical stability, which can be reused for more than 30 extraction times without any significant loss in the extraction recoveries of PAEs. The AC-poly(STY-DVB) monolithic column was successfully applied in SPME of PAEs in water sample with extraction recovery ranged of 78.8%-104.6% (<5.5% RSDs). (C) 2016 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:55 / 63
页数:9
相关论文
共 50 条
  • [31] Effect of the Compositions of Sample and Polymer Sorbents on the Extraction of Volatile Compounds by Solid-Phase Microextraction
    T. A. Misharina
    M. B. Terenina
    N. I. Krikunova
    I. A. Mihailov
    Applied Biochemistry and Microbiology, 2018, 54 : 89 - 97
  • [32] Comparison of Solid-Phase Extraction and Solid-Phase Microextraction Using Octadecylsilane Phase for the Determination of Pesticides in Water Samples
    Prieto, Avismelsi
    Araujo, Lilia
    Navalon, Alberto
    Vilchez, Jose L.
    CURRENT ANALYTICAL CHEMISTRY, 2009, 5 (03) : 219 - 224
  • [33] Copper ferrite nanoparticles as novel coating appropriated to solid-phase microextraction of phthalate esters from aqueous matrices
    Wu, Dechang
    Liu, Fu
    Tian, Tong
    Wu, Jian-Feng
    Zhao, Guang-Chao
    MICROCHEMICAL JOURNAL, 2021, 162
  • [34] Phenylenediboronic acid-intercalated MXene-based adsorbent for solid-phase microextraction of phthalate esters in jams
    Liu, Shuo
    Li, Yahuan
    Zang, Xiaohuan
    Chang, Qingyun
    Zhang, Shuaihua
    Wang, Chun
    Wang, Zhi
    MICROCHEMICAL JOURNAL, 2024, 200
  • [35] Solid-phase microextraction of phthalate esters by a new coating based on a thermally stable polypyrrole/graphene oxide composite
    Jafari, Mostafa
    Ebrahimzadeh, Homeira
    Banitaba, Mohammad Hossein
    Davarani, Saied Saeed Hosseiny
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (21) : 3142 - 3149
  • [36] Electrochemical preparation of zinc oxide/polypyrrole nanocomposite coating for the highly effective solid-phase microextraction of phthalate esters
    Zakerian, Razieh
    Bahar, Soleiman
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (22) : 4439 - 4445
  • [37] Preparation and evaluation of a new solid-phase microextraction fiber based on polythionine for analysis of phthalate esters in aqueous samples
    Ali Ahmad Moahammadi
    Saied Saeed Hosseiny Davarani
    Mostafa Jafari
    Ali Mehdinia
    Journal of the Iranian Chemical Society, 2021, 18 : 385 - 391
  • [38] Application of electro-enhanced solid-phase microextraction for determination of phthalate esters and bisphenol A in blood and seawater samples
    Mousa, Amayreh
    Basheer, Chanbasha
    Al-Arfaj, Abdul Rahman
    TALANTA, 2013, 115 : 308 - 313
  • [39] Preparation and evaluation of a new solid-phase microextraction fiber based on polythionine for analysis of phthalate esters in aqueous samples
    Moahammadi, Ali Ahmad
    Davarani, Saied Saeed Hosseiny
    Jafari, Mostafa
    Mehdinia, Ali
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2021, 18 (02) : 385 - 391
  • [40] Solid-Phase Microextraction of Phthalate Esters from Aqueous Media by Functionalized Carbon Nanotubes (Graphene Oxide Nanoribbons) and Determination by GC-FID
    Kazemi, Maryam
    Niazi, Ali
    Yazdanipour, Atisa
    CHROMATOGRAPHIA, 2021, 84 (06) : 559 - 569