Solid-phase microextraction of phthalate esters in water sample using different activated carbon-polymer monoliths as adsorbents

被引:43
|
作者
Lirio, Stephen [1 ]
Fu, Chung-Wei [1 ]
Lin, Jhih-Yun [1 ]
Hsu, Meng-Ju [1 ]
Huang, Hsi-Ya [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Chem, 200 Chung Pei Rd, Taoyuan 320, Taiwan
关键词
Phthalate ester; Poly(styrene-divinylbenzene); Activated carbon; Polymer monolith; Solid-phase microextraction; CHROMATOGRAPHY MASS-SPECTROMETRY; PI-PI-INTERACTIONS; GAS-CHROMATOGRAPHY; RIVER WATER; FIBER; EXTRACTION; COLUMNS; OXIDE; CONTAMINATION; ENRICHMENT;
D O I
10.1016/j.aca.2016.05.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the application of different activated carbon-polymer (AC-polymer) monoliths as adsorbents for the solid-phase microextraction (SPME) of phthalate esters (PAEs) in water sample were investigated. The activated carbon (AC) was embedded in organic polymers, poly(butyl methacrylate-co-ethylene dimethacrylate) (poly(BMA-EDMA)) or poly(styrene-co-divinylbenzene) (poly(STY-DVB)), via a 5-min microwave-assisted or a 15-min water bath heating polymerization. Preliminary investigation on the performance of the native poly(BMA-EDMA) and poly(STY-DVB) demonstrated remarkable adsorption efficiencies for PAEs. However, due to the strong hydrophobic, pi-pi, and hydrogen bonding interactions between the analytes and polymers, low extraction recoveries were achieved. In contrast, the presence of AC in native polymers not only enhanced the adsorption efficiencies but also assisted the PAE desorption, especially for AC-poly(STY-DVB) with extraction recovery ranged of 76.2-99.3%. Under the optimized conditions, the extraction recoveries for intra-, inter-day and column-to-column were in the range of 76.5-100.8% (<3.7% RSDs), 77.2-97.6% (<5.6% RSDs) and 75.5-99.7% (<6.2% RSDs), respectively. The developed AC-poly(STY-DVB) monolithic column showed good mechanical stability, which can be reused for more than 30 extraction times without any significant loss in the extraction recoveries of PAEs. The AC-poly(STY-DVB) monolithic column was successfully applied in SPME of PAEs in water sample with extraction recovery ranged of 78.8%-104.6% (<5.5% RSDs). (C) 2016 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:55 / 63
页数:9
相关论文
共 50 条
  • [21] Bamboo charcoal as a novel solid-phase microextraction coating material for enrichment and determination of eleven phthalate esters in environmental water samples
    Ru-Song Zhao
    Yan-Long Liu
    Jia-Bin Zhou
    Xiang-Feng Chen
    Xia Wang
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4993 - 4996
  • [22] Development of a solid-phase microextraction method for the determination of phthalic acid esters in water
    Prokupková, G
    Holadová, K
    Poustka, J
    Hajslová, J
    ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 211 - 223
  • [23] Quinoxaline core-conjugated microporous polymer coating for highly sensitive solid-phase microextraction of phthalate esters in liquid food samples
    Gang Xiang
    Wenzhuo Li
    Qiuxiang Nong
    Cuizhong Zhang
    Zhengfa Zhang
    Huan Lian
    Jinyun Peng
    Yufen Jiang
    Yiqiu Tan
    Jing Sun
    Journal of Food Measurement and Characterization, 2023, 17 : 6168 - 6179
  • [24] Quinoxaline core-conjugated microporous polymer coating for highly sensitive solid-phase microextraction of phthalate esters in liquid food samples
    Xiang, Gang
    Li, Wenzhuo
    Nong, Qiuxiang
    Zhang, Cuizhong
    Zhang, Zhengfa
    Lian, Huan
    Peng, Jinyun
    Jiang, Yufen
    Tan, Yiqiu
    Sun, Jing
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2023, 17 (06) : 6168 - 6179
  • [25] The benefits of using solid-phase microextraction as a greener sample preparation technique
    Bojko, Barbara
    Pawliszyn, Janusz
    BIOANALYSIS, 2012, 4 (11) : 1263 - 1265
  • [26] Determination of Phthalate Esters in Water and Coffee by Solid-Phase Microextraction Using Vinyl Terminated Imidazolium Based Ionic Liquid Grafted on Graphene Oxide Coatings
    Tashakkori, Paniz
    Erdem, Pelin
    Merdivan, Melek
    Bozkurt, Serap Seyhan
    CHEMISTRYSELECT, 2019, 4 (08): : 2307 - 2313
  • [27] Sample Preparation for Gas Chromatography Using Solid-Phase Microextraction with Derivatization
    Snow, Nicholas H.
    ADVANCES IN CHROMATOGRAPHY, VOL 48, 2010, 48 : 373 - +
  • [28] Solid-phase microextraction of phthalate esters from aqueous media by electrochemically deposited carbon nanotube/polypyrrole composite on a stainless steel fiber
    Asadollahzadeh, H.
    Noroozian, E.
    Maghsoudi, Sh.
    ANALYTICA CHIMICA ACTA, 2010, 669 (1-2) : 32 - 38
  • [29] Solid-Phase Microextraction of Phthalate Esters from Aqueous Media by Functionalized Carbon Nanotubes (Graphene Oxide Nanoribbons) and Determination by GC–FID
    Maryam Kazemi
    Ali Niazi
    Atisa Yazdanipour
    Chromatographia, 2021, 84 : 559 - 569
  • [30] Effect of the Compositions of Sample and Polymer Sorbents on the Extraction of Volatile Compounds by Solid-Phase Microextraction
    Misharina, T. A.
    Terenina, M. B.
    Krikunova, N. I.
    Mihailov, I. A.
    APPLIED BIOCHEMISTRY AND MICROBIOLOGY, 2018, 54 (01) : 89 - 97