Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:66
|
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 50 条
  • [31] Hepatic lesion detection and characterization:: Value of nonenhanced MR imaging, superparamagnetic iron oxide-enhanced MR imaging, and spiral CT-ROC analysis
    Reimer, P
    Jähnke, N
    Fiebich, M
    Schima, W
    Deckers, F
    Marx, C
    Holzknecht, N
    Saini, S
    RADIOLOGY, 2000, 217 (01) : 152 - 158
  • [32] Focal hepatic lesions: Detection and characterization with combination gadolinium- and superparamagnetic iron oxide-enhanced MR imaging
    Kim, MJ
    Kim, JH
    Chung, JJ
    Park, MS
    Lim, LS
    Oh, YT
    RADIOLOGY, 2003, 228 (03) : 719 - 726
  • [33] Fast gradient echo MR imaging of the liver enhanced with superparamagnetic iron oxide
    Fishbein, M
    Long, F
    Smith, M
    MAGNETIC RESONANCE IMAGING, 1997, 15 (06) : 651 - 655
  • [34] Lymph node metastasis: Ultrasmall superparamagnetic iron oxide-enhanced MR imaging versus PET/CT in a rabbit model
    Choi, Seung Hong
    Moon, Woo Kyung
    Hong, Ju Hee
    Son, Kyu Ri
    Cho, Nariya
    Kwon, Bae Ju
    Lee, Jong Jin
    Chung, June-Key
    Min, Hye Sock
    Park, Seong Ho
    RADIOLOGY, 2007, 242 (01) : 137 - 143
  • [35] Study on super-paramagnetic iron oxide-enhanced liver MR imaging in rats
    王莉
    田建明
    陆建平
    刘崎
    曾浩
    陈爱华
    陶文照
    Journal of Medical Colleges of PLA, 2001, (02) : 125 - 128
  • [36] Detection of hypervascular malignant foci in borderline lesions of hepatocellular carcinoma: comparison of dynamic multi-detector row CT, dynamic MR imaging and superparamagnetic iron oxide-enhanced MR imaging
    Shinmura, Rieko
    Matsui, Osamu
    Kadoya, Masumi
    Kobayashi, Satoshi
    Terayama, Noboru
    Sanada, Junichiro
    Demachi, Hiroshi
    Gabata, Toshifumi
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1918 - 1924
  • [37] Detection of hypervascular malignant foci in borderline lesions of hepatocellular carcinoma: comparison of dynamic multi-detector row CT, dynamic MR imaging and superparamagnetic iron oxide-enhanced MR imaging
    Rieko Shinmura
    Osamu Matsui
    Masumi Kadoya
    Satoshi Kobayashi
    Noboru Terayama
    Junichiro Sanada
    Hiroshi Demachi
    Toshifumi Gabata
    European Radiology, 2008, 18 : 1918 - 1924
  • [38] Superparamagnetic iron oxide-enhanced MR imaging for early and late radiation-induced hepatic injuries
    Yoshioka, H
    Itai, Y
    Saida, Y
    Mori, K
    Mori, H
    Okumura, T
    MAGNETIC RESONANCE IMAGING, 2000, 18 (09) : 1079 - 1088
  • [39] DEVELOPMENT OF HEPATOMA IN HYPERPLASTIC NODULES INDUCED IN RAT LIVERS - DETECTION WITH SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR-IMAGING
    YAMAMOTO, H
    YAMASHITA, Y
    TAKAHASHI, M
    RADIOLOGY, 1995, 197 : 414 - 414
  • [40] Superparamagnetic iron oxide-enhanced MR imaging of hepatocellular carcinoma - Correlation with histological grading and tumor vascularity
    Imai, Y
    Nishikawa, M
    Kurokawa, M
    Zushi, S
    Yonezawa, T
    Yoshida, S
    Tokunaga, K
    Murata, M
    Shibata, K
    Shimano, T
    Osawa, M
    Murakami, T
    Nakamura, H
    HEPATOLOGY, 1998, 28 (04) : 246A - 246A