Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:66
|
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 50 条
  • [21] Small colorectal liver metastases: Detection with SPIO-enhanced MRI in comparison with gadobenate dimeglumine-enhanced MRI and CT imaging
    Hekimoglu, Koray
    Ustundag, Yucel
    Dusak, Abdurrahim
    Kalaycioglu, Bora
    Besir, Halit
    Engin, Huseyin
    Erdem, Oktay
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (03) : 468 - 472
  • [22] Ultrasmall superparamagnetic iron oxide-enhanced MR imaging of atherosclerotic plaque in hyperlipidemic rabbits
    Ruehm, SG
    Corot, C
    Vogt, P
    Cristina, H
    Debatin, JF
    ACADEMIC RADIOLOGY, 2002, 9 : S143 - S144
  • [23] Gadobenate Dimeglumine-Enhanced Liver Magnetic Resonance Imaging: Value of Hepatobiliary Phase for the Detection of Focal Liver Lesions
    Fu, Guo-li
    Du, Yong
    Zee, Chi-shing
    Yang, Han-feng
    Li, Yang
    Duan, Ru-gang
    Zeng, Nan-lin
    Xiao, Dong-Mei
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) : 14 - 19
  • [24] Ultrasmall superparamagnetic iron oxide enhanced MR imaging for lymph node metastases
    Russell, Mai
    Anzai, Yoshimi
    RADIOGRAPHY, 2007, 13 : E73 - E84
  • [25] Small hypervascular hepatocellular carcinomas: value of “washout” on gadolinium-enhanced dynamic MR imaging compared to superparamagnetic iron oxide-enhanced imaging
    Jeong-Sik Yu
    Jae-Joon Chung
    Joo Hee Kim
    Ki Whang Kim
    European Radiology, 2009, 19 : 2614 - 2622
  • [26] Small hypervascular hepatocellular carcinomas: value of "washout" on gadolinium-enhanced dynamic MR imaging compared to superparamagnetic iron oxide-enhanced imaging
    Yu, Jeong-Sik
    Chung, Jae-Joon
    Kim, Joo Hee
    Kim, Ki Whang
    EUROPEAN RADIOLOGY, 2009, 19 (11) : 2614 - 2622
  • [27] DETECTION OF LIVER METASTASES - COMPARISON OF SUPERPARAMAGNETIC IRON OXIDE-ENHANCED AND UNENHANCED MR-IMAGING ART 1.5 T WITH DYNAMIC CT, INTRAOPERATIVE US, AND PERCUTANEOUS US
    HAGSPIEL, KD
    NEIDL, KFW
    EICHENBERGER, AC
    WEDER, W
    MARINCEK, B
    RADIOLOGY, 1995, 196 (02) : 471 - 478
  • [28] Characterization of focal liver lesions with superparamagnetic iron oxide-enhanced MR imaging: Value of distributional phase T1-weighted imaging
    Lee, JM
    Kim, CS
    Youk, JH
    Lee, MS
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (01) : 9 - 18
  • [29] The limited value of superparamagnetic iron oxide (SPIO)-enhanced MR imaging for detection of hepatocellular carcinoma: Comparison with dynamic gadolinium-enhanced MR imaging
    Tang, Y
    Lan, L
    Abe, Y
    Yamashita, Y
    Namimoto, T
    Takahashi, M
    RADIOLOGY, 1998, 209P : 373 - 374
  • [30] Detection of Small Hepatocellular Carcinoma Can Gadoxetic Acid-Enhanced Magnetic Resonance Imaging Replace Combining Gadopentetate Dimeglumine-Enhanced and Superparamagnetic Iron Oxide-Enhanced Magnetic Resonance Imaging?
    Kim, Young Kon
    Kim, Chong Soo
    Han, Young Min
    Park, Gun
    INVESTIGATIVE RADIOLOGY, 2010, 45 (11) : 740 - 746