Experimental Assessment of the Accuracy of a Semi-Empirical Model and a Monte Carlo System for Proton Dose Calculations for Highly Inhomogeneous Media

被引:0
|
作者
Mohan, R.
Mirkovic, D.
Titt, U.
Song, X.
Li, H.
Zhu, X.
Chin, M.
机构
关键词
D O I
10.1118/1.3612649
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-687
引用
收藏
页数:2
相关论文
共 35 条
  • [1] Experimental assessment of proton dose calculation accuracy in inhomogeneous media
    Sorriaux, J.
    Testa, M.
    Paganetti, H.
    de Xivry, J. Orban
    Lee, J. A.
    Traneus, E.
    Souris, K.
    Vynckier, S.
    Sterpin, E.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 : 10 - 15
  • [2] Experimental validation of the DPM Monte Carlo code for photon beam dose calculations in inhomogeneous media
    Chetty, I
    Charland, P
    Tyagi, N
    McShan, D
    Fraass, B
    Bielajew, A
    MEDICAL PHYSICS, 2002, 29 (06) : 1351 - 1351
  • [3] Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculations
    Kohno, R
    Takada, Y
    Sakae, T
    Terunuma, T
    Matsumoto, K
    Nohtomi, A
    Matsuda, H
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (10): : 1277 - 1288
  • [4] A semi-empirical Monte Carlo based model of the Detector Optical Gain of Nuclear Imaging scintillators
    Nikolopoulos, D.
    Kalyvas, N.
    Valais, I.
    Argyriou, X.
    Vlamakis, E.
    Sevvos, T.
    Kandarakis, I.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [5] Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media
    Tyagi, N.
    Curran, B. H.
    Roberson, P. L.
    Moran, J. M.
    Acosta, E.
    Fraass, B. A.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [6] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for lung dose calculations
    Mesbahi, Asghar
    Thwaites, David I.
    Reilly, Andrew J.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (03) : 123 - 133
  • [7] Effect of surface diffusion algorithm on nanostructure formation in a semi-empirical Monte Carlo model of sputter erosion of materials
    Oyewande, Oluwole E.
    Babalola, Israel B.
    Usikalu, Mojisola
    3RD INTERNATIONAL CONFERENCE ON SCIENCE AND SUSTAINABLE DEVELOPMENT (ICSSD 2019): SCIENCE, TECHNOLOGY AND RESEARCH: KEYS TO SUSTAINABLE DEVELOPMENT, 2019, 1299
  • [8] Uncertainty assessment of a semi-empirical output voltage model for proton exchange membrane fuel cells
    Liu, Xiangwan
    Yang, Yang
    Zhang, Lingxian
    Zhou, Shenpei
    Xu, Lamei
    Xie, Changjun
    Zhao, Bo
    Zhang, Leiqi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (29) : 11071 - 11085
  • [9] An adaptive emission model for Monte Carlo simulations in highly inhomogeneous media represented by stochastic particle fields
    Wang, Anquan
    Modest, Michael F.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2007, 104 (02): : 288 - 296
  • [10] Physics Considerations Regarding Dosimetric Accuracy of Analytical Dose Calculations for Small Field Proton Therapy: A Monte Carlo Study
    Geng, C.
    Daartz, J.
    Cheung, K.
    Bussiere, M.
    Shih, H.
    Paganetti, H.
    Schuemann, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3498 - 3498