Electropolymerized Molecularly Imprinted Polypyrrole Film for Sensing of Clofibric Acid

被引:55
|
作者
Schweiger, Bianca [1 ]
Kim, Jungtae [1 ]
Kim, Young Jun [1 ]
Ulbricht, Mathias [2 ]
机构
[1] KIST Europe Forsch Gesell mbH, D-66123 Saarbrucken, Germany
[2] Univ Duisburg Essen, Lehrstuhl Tech Chem 2, D-45141 Essen, Germany
来源
SENSORS | 2015年 / 15卷 / 03期
关键词
molecularly imprinted polymer; polypyrrole; clofibric acid; quartz crystal microbalance; electrochemical polymerization; amperometric sensor; PENCIL GRAPHITE ELECTRODE; FLOW-INJECTION ANALYSIS; WASTE-WATER TREATMENT; OVEROXIDIZED POLYPYRROLE; ELECTROCHEMICAL SENSOR; ELECTROINACTIVE ANIONS; CONDUCTING POLYMERS; CARBON ELECTRODE; PHARMACEUTICALS; SURFACE;
D O I
10.3390/s150304870
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Piezoelectric quartz crystals and analogous gold substrates were electrochemically coated with molecularly imprinted polypyrrole films for pulsed amperometric detection (PAD) of clofibric acid, a metabolite of clofibrate. Cyclic voltammetry data obtained during polymerization and deposited weight estimations revealed a decrease of the polymerization rate with increasing clofibric acid concentration. XPS measurements indicated that clofibric acid could be removed after imprinting with an aqueous ethanol solution, which was further optimized by using PAD. Zeta potential and contact angle measurements revealed differences between molecularly imprinted (MIP) and non-imprinted polymer (NIP) layers. Binding experiments with clofibric acid and other substances showed a pronounced selectivity of the MIP for clofibric acid vs. carbamazepine, but the response of MIP and NIP to 2,4-dichlorophenoxyacetic acid was higher than that for clofibric acid. A smooth surface, revealed by AFM measurements, with roughness of 6-8 nm for imprinted and non-imprinted layers, might be a reason for an excessively low density of specific binding sites for clofibric acid. Furthermore, the decreased polymerization rate in the presence of clofibric acid might not result in well-defined polymer structures, which could be the reason for the lower sensitivity.
引用
收藏
页码:4870 / 4889
页数:20
相关论文
共 50 条
  • [31] Capacitive detection of theophylline based on electropolymerized molecularly imprinted polymer
    Wang, Zhihua
    Kang, Jingwan
    Liu, Xiaoyu
    Ma, Yongjun
    [J]. INTERNATIONAL JOURNAL OF POLYMER ANALYSIS AND CHARACTERIZATION, 2007, 12 (02) : 131 - 142
  • [32] Magneto-electropolymerized film formation of polypyrrole
    Mogi, I
    [J]. MICROELECTRONIC ENGINEERING, 1998, 43-4 : 739 - 744
  • [33] Electropolymerized Polypyrrole Nanowires for Hydrogen Gas Sensing
    Al-Mashat, Laith
    Debiemme-Chouvy, Catherine
    Borensztajn, Stephan
    Wlodarski, Wojtek
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2012, 116 (24): : 13388 - 13394
  • [34] Xanthine microsensor based on polypyrrole molecularly imprinted film modified carbon fiber microelectrodes
    Liu, Bin
    Wang, Xiao-Li
    Lian, Hui-Ting
    Sun, Xiang-Ying
    [J]. ANALYTICAL BIOCHEMISTRY, 2013, 440 (02) : 220 - 226
  • [35] Electrosynthesis of molecularly imprinted polypyrrole for the antibiotic levofloxacin
    Mazzotta, Elisabetta
    Malitesta, Cosimino
    Diaz-Alvarez, Myriam
    Martin-Esteban, Antonio
    [J]. THIN SOLID FILMS, 2012, 520 (06) : 1938 - 1943
  • [36] Preparation of Molecularly Imprinted Polypyrrole and Carbon Nanotubes Film Modified Electrode for Dopamine Recognition
    Zhang, FeiFei
    Wang, ZongHua
    Xia, JianFei
    Xia, YanZhi
    Cai, Feng
    Li, YanHui
    [J]. ADVANCED RESEARCH ON ENERGY MATERIALS AND MATERIAL APPLICATION, 2012, 578 : 105 - +
  • [37] STM OBSERVATION OF ELECTROPOLYMERIZED POLYPYRROLE FILM IN SOLUTION
    NAOI, K
    OURA, Y
    [J]. DENKI KAGAKU, 1993, 61 (07): : 818 - 819
  • [38] Polypyrrole Molecularly Imprinted Modified Glassy Carbon Electrode for the Recognition of Gallic Acid
    Jara-Ulloa, Paola
    Salgado-Figueroa, Paola
    Moscoso, Raul
    Arturo Squella, Juan
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (04) : H243 - H246
  • [39] An microelectrode based on molecularly imprinted oligomer film for rapid electrochemical sensing
    Huan, SY
    Hu, SQ
    Shen, GL
    Yu, RQ
    [J]. ANALYTICAL LETTERS, 2003, 36 (11) : 2401 - 2416
  • [40] Molecularly imprinted electrochemical sensor based on polypyrrole/dopamine@graphene incorporated with surface molecularly imprinted polymers thin film for recognition of olaquindox
    Bai, Xiaoyun
    Zhang, Bo
    Liu, Miao
    Hu, Xuelian
    Fang, Guozhen
    Wang, Shuo
    [J]. BIOELECTROCHEMISTRY, 2020, 132