Electropolymerized Molecularly Imprinted Polypyrrole Film for Sensing of Clofibric Acid

被引:55
|
作者
Schweiger, Bianca [1 ]
Kim, Jungtae [1 ]
Kim, Young Jun [1 ]
Ulbricht, Mathias [2 ]
机构
[1] KIST Europe Forsch Gesell mbH, D-66123 Saarbrucken, Germany
[2] Univ Duisburg Essen, Lehrstuhl Tech Chem 2, D-45141 Essen, Germany
来源
SENSORS | 2015年 / 15卷 / 03期
关键词
molecularly imprinted polymer; polypyrrole; clofibric acid; quartz crystal microbalance; electrochemical polymerization; amperometric sensor; PENCIL GRAPHITE ELECTRODE; FLOW-INJECTION ANALYSIS; WASTE-WATER TREATMENT; OVEROXIDIZED POLYPYRROLE; ELECTROCHEMICAL SENSOR; ELECTROINACTIVE ANIONS; CONDUCTING POLYMERS; CARBON ELECTRODE; PHARMACEUTICALS; SURFACE;
D O I
10.3390/s150304870
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Piezoelectric quartz crystals and analogous gold substrates were electrochemically coated with molecularly imprinted polypyrrole films for pulsed amperometric detection (PAD) of clofibric acid, a metabolite of clofibrate. Cyclic voltammetry data obtained during polymerization and deposited weight estimations revealed a decrease of the polymerization rate with increasing clofibric acid concentration. XPS measurements indicated that clofibric acid could be removed after imprinting with an aqueous ethanol solution, which was further optimized by using PAD. Zeta potential and contact angle measurements revealed differences between molecularly imprinted (MIP) and non-imprinted polymer (NIP) layers. Binding experiments with clofibric acid and other substances showed a pronounced selectivity of the MIP for clofibric acid vs. carbamazepine, but the response of MIP and NIP to 2,4-dichlorophenoxyacetic acid was higher than that for clofibric acid. A smooth surface, revealed by AFM measurements, with roughness of 6-8 nm for imprinted and non-imprinted layers, might be a reason for an excessively low density of specific binding sites for clofibric acid. Furthermore, the decreased polymerization rate in the presence of clofibric acid might not result in well-defined polymer structures, which could be the reason for the lower sensitivity.
引用
收藏
页码:4870 / 4889
页数:20
相关论文
共 50 条
  • [21] Interaction of ochratoxin A with molecularly imprinted polypyrrole film on surface plasmon resonance sensor
    Yu, JCC
    Lai, EPC
    [J]. REACTIVE & FUNCTIONAL POLYMERS, 2005, 63 (03): : 171 - 176
  • [22] Molecular recognition for bile acids using a molecularly imprinted overoxidized polypyrrole film
    Shiigi, H
    Kijima, D
    Ikenaga, Y
    Hori, K
    Fukazawa, S
    Nagaoka, T
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (08) : H129 - H134
  • [23] Molecularly imprinted thin film surfaces in sensing: Chances and challenges
    Unger, Christine
    Lieberzeit, Peter A.
    [J]. REACTIVE & FUNCTIONAL POLYMERS, 2021, 161
  • [24] Removal of carbamazepine and clofibric acid from water using double templates–molecularly imprinted polymers
    Chao-meng Dai
    Juan Zhang
    Ya-lei Zhang
    Xue-fei Zhou
    Yan-ping Duan
    Shu-guang Liu
    [J]. Environmental Science and Pollution Research, 2013, 20 : 5492 - 5501
  • [25] Molecularly imprinted polyaniline film for ascorbic acid detection
    Roy, Abani Kumar
    Nisha, V. S.
    Dhand, Chetna
    Malhotra, Bansi D.
    [J]. JOURNAL OF MOLECULAR RECOGNITION, 2011, 24 (04) : 700 - 706
  • [26] Publisher Correction to: Electropolymerized‑molecularly imprinted polymers (E‑MIPS) as sensing elements for the detection of dengue infection
    Clarisse E. Buensuceso
    Brylee David B. Tiu
    Luke P. Lee
    Portia Mahal G. Sabido
    Guillermo M. Nuesca
    Eugene B. Caldona
    Florian R. del Mundo
    Rigoberto C. Advincula
    [J]. Analytical and Bioanalytical Chemistry, 2022, 414 : 1457 - 1458
  • [27] Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection
    Buensuceso, Clarisse E.
    Tiu, Brylee David B.
    Lee, Luke P.
    Sabido, Portia Mahal G.
    Nuesca, Guillermo M.
    Caldona, Eugene B.
    del Mundo, Florian R.
    Advincula, Rigoberto C.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (03) : 1347 - 1357
  • [28] Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection
    Clarisse E. Buensuceso
    Brylee David B. Tiu
    Luke P. Lee
    Portia Mahal G. Sabido
    Guillermo M. Nuesca
    Eugene B. Caldona
    Florian R. del Mundo
    Rigoberto C. Advincula
    [J]. Analytical and Bioanalytical Chemistry, 2022, 414 : 1347 - 1357
  • [29] Determination of benzimidazole in biological model samples using electropolymerized-molecularly imprinted polypyrrole modified pencil graphite sensor
    Nezhadali, Azizollah
    Mehri, Leili
    Shadmehri, Raham
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 1125 - 1131
  • [30] Facile preparation of molecularly imprinted polypyrrole-graphene-multiwalled carbon nanotubes composite film modified electrode for rutin sensing
    Yang, Lite
    Yang, Juan
    Xu, Bingjie
    Zhao, Faqiong
    Zeng, Baizhao
    [J]. TALANTA, 2016, 161 : 413 - 418