Assessing the inter-rater and intra-rater reliability of the Physical Therapy Competence Assessment for Airway Suctioning (PT-CAAS)

被引:0
|
作者
Miller, Erin [1 ,2 ]
Brooks, Dina [1 ,2 ,3 ,4 ,5 ]
O'Brien, Kelly K. [1 ,2 ,6 ]
Beavers, Lindsay [2 ,7 ]
Stratford, Paul [3 ]
Nonoyama, Mika [1 ,2 ,8 ,9 ]
Mori, Brenda [1 ,2 ]
机构
[1] Univ Toronto, Rehabil Sci Inst, 500 Univ Ave,Suite 160, Toronto, ON M5G 1V7, Canada
[2] Univ Toronto, Dept Phys Therapy, Toronto, ON, Canada
[3] McMaster Univ, Sch Rehabil Sci, Hamilton, ON, Canada
[4] West Pk Healthcare Ctr, Toronto, ON, Canada
[5] Univ Toronto, Dept Med, Toronto, ON, Canada
[6] Univ Toronto, Inst Hlth Policy Management & Evaluat IHPME, Toronto, ON, Canada
[7] Unity Hlth Toronto, Toronto, ON, Canada
[8] Ontario Tech Univ, Fac Hlth Sci, Oshawa, ON, Canada
[9] Hosp Sick Children, Resp Therapy & Child Hlth Evaluat Sci, Toronto, ON, Canada
关键词
clinical competence; observer variation; physical therapists; suction; PHYSIOTHERAPY; SKILLS;
D O I
10.1002/pri.1944
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background and Purpose: The Physical Therapy Competence Assessment for Airway Suctioning (PT-CAAS) is a recently developed measure to assess the clinical competence of physiotherapists who perform airway suctioning with adults. The purpose of this study was to assess the inter-rater and intra-rater reliability of the PT-CAAS. Methods: Scoring rules were developed through expert consultation. Reliability was then assessed using nine videos of suctioning performed in a simulated learning environment. A repeated measures design was used, with two replicate sets of measurements made by each participant for all videos. Data were analyzed using a repeated measures model for the concurrent assessment of inter-rater and intrarater reliability. Participants were physiotherapists with suctioning experience. Results: Twenty physiotherapists completed initial scoring and re-scoring for all nine videos; their data were included in the analysis. Intraclass correlation coefficients (ICCs) for inter-rater reliability ranged from 0.569 [lower one-sided 95% confidence interval (CI): 0.395; standard error of measurement (SEM): 0.963] for infection control to 0.759 (lower one-sided 95% CI: 0.612; SEM: 0.722) for post-suctioning assessment and care. The inter-rater ICC for overall performance was 0.752 (lower one-sided 95% CI: 0.602; SEM: 0.660). ICCs for intra-rater reliability ranged from 0.759 (lower one-sided 95% CI: 0.197; SEM 0.721) for infection control to 0.860 (lower one-sided 95% CI: 0.544; SEM: 0.550) for post-suctioning assessment and care. The intra-rater ICC for overall performance was 0.867 (lower one-sided 95% CI: 0.559; SEM: 0.483). Discussion: Evidence of moderate to good inter-rater and good intra-rater reliability was found; however, the results should be interpreted with caution given the wide Cis and relatively large SEMs. Improved assessor training and assessments of reliability using a larger sample size are recommended.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Assessment of the posture of adolescents in everyday clinical practice: Intra-rater and inter-rater reliability and validity of a posture index
    Ludwig, Oliver
    Hammes, Annette
    Kelm, Jens
    Schmitt, Eduard
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2016, 20 (04) : 761 - 766
  • [42] Inter and intra-rater reliability of the scoliometer
    Bonagamba, Guilherme H.
    Coelho, Daniel M.
    de Oliveira, Anamaria S.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2010, 14 (05) : 432 - 437
  • [43] Use of superpixels for improvement of inter-rater and intra-rater reliability during annotation of medical images
    Gut, Daniel
    Trombini, Marco
    Kucybala, Iwona
    Krupa, Kamil
    Rozynek, Milosz
    Dellepiane, Silvana
    Tabor, Zbislaw
    Wojciechowski, Wadim
    MEDICAL IMAGE ANALYSIS, 2024, 94
  • [44] Evaluation of the inter-rater and intra-rater reliability of a protocol for the measurement of foot-transmitted vibration
    Vance, Brandon
    Goggins, Katie A.
    Godwin, Alison
    Oddson, Bruce E.
    Eger, Tammy R.
    THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2021, 22 (02) : 219 - 236
  • [45] Intra-rater and inter-rater reliability of scapular asymmetry measurements in male professional volleyball players
    Paraskevopoulos, Eleftherios
    Sasati, Dimitrios
    Papandreou, Maria
    MEDICINA DELLO SPORT, 2019, 72 (03) : 404 - 421
  • [46] Inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurement from MRI
    McGibbon, CA
    MAGNETIC RESONANCE IMAGING, 2003, 21 (07) : 707 - 714
  • [47] Sunnybrook Facial Grading System: Intra-rater and Inter-rater Variabilities
    Cabrol, Camille
    Elarouti, Lea
    Montava, Anne-Laure
    Jarze, Sylvie
    Mancini, Julien
    Lavieille, Jean-Pierre
    Barry, Pauline
    Montava, Marion
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : 1089 - 1094
  • [48] Use of superpixels for improvement of inter-rater and intra-rater reliability during annotation of medical images
    Gut, Daniel
    Trombini, Marco
    Kucybala, Iwona
    Krupa, Kamil
    Rozynek, Milosz
    Dellepiane, Silvana
    Tabor, Zbislaw
    Wojciechowski, Wadim
    Medical Image Analysis, 2024, 94
  • [49] Inter-rater and Intra-rater Reliability in the Radiographic Diagnosis of Growth Arrest in Paediatric Physeal Fractures
    Banting, Nicole
    Schaeffer, Emily K.
    Bone, Jeffrey
    Habib, Eva
    Hooper, Nikki
    Reilly, Christopher W.
    Cooper, Anthony
    Mulpuri, Kishore
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (SUPPL 2) : 445 - 451
  • [50] Intra-rater and Inter-rater consistency of drug induced sleep endoscopy
    Kilavuz, Ahmet Erdem
    Bayram, Ali Alper
    ENT UPDATES, 2019, 9 (02): : 138 - 143