Assessing the inter-rater and intra-rater reliability of the Physical Therapy Competence Assessment for Airway Suctioning (PT-CAAS)

被引:0
|
作者
Miller, Erin [1 ,2 ]
Brooks, Dina [1 ,2 ,3 ,4 ,5 ]
O'Brien, Kelly K. [1 ,2 ,6 ]
Beavers, Lindsay [2 ,7 ]
Stratford, Paul [3 ]
Nonoyama, Mika [1 ,2 ,8 ,9 ]
Mori, Brenda [1 ,2 ]
机构
[1] Univ Toronto, Rehabil Sci Inst, 500 Univ Ave,Suite 160, Toronto, ON M5G 1V7, Canada
[2] Univ Toronto, Dept Phys Therapy, Toronto, ON, Canada
[3] McMaster Univ, Sch Rehabil Sci, Hamilton, ON, Canada
[4] West Pk Healthcare Ctr, Toronto, ON, Canada
[5] Univ Toronto, Dept Med, Toronto, ON, Canada
[6] Univ Toronto, Inst Hlth Policy Management & Evaluat IHPME, Toronto, ON, Canada
[7] Unity Hlth Toronto, Toronto, ON, Canada
[8] Ontario Tech Univ, Fac Hlth Sci, Oshawa, ON, Canada
[9] Hosp Sick Children, Resp Therapy & Child Hlth Evaluat Sci, Toronto, ON, Canada
关键词
clinical competence; observer variation; physical therapists; suction; PHYSIOTHERAPY; SKILLS;
D O I
10.1002/pri.1944
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background and Purpose: The Physical Therapy Competence Assessment for Airway Suctioning (PT-CAAS) is a recently developed measure to assess the clinical competence of physiotherapists who perform airway suctioning with adults. The purpose of this study was to assess the inter-rater and intra-rater reliability of the PT-CAAS. Methods: Scoring rules were developed through expert consultation. Reliability was then assessed using nine videos of suctioning performed in a simulated learning environment. A repeated measures design was used, with two replicate sets of measurements made by each participant for all videos. Data were analyzed using a repeated measures model for the concurrent assessment of inter-rater and intrarater reliability. Participants were physiotherapists with suctioning experience. Results: Twenty physiotherapists completed initial scoring and re-scoring for all nine videos; their data were included in the analysis. Intraclass correlation coefficients (ICCs) for inter-rater reliability ranged from 0.569 [lower one-sided 95% confidence interval (CI): 0.395; standard error of measurement (SEM): 0.963] for infection control to 0.759 (lower one-sided 95% CI: 0.612; SEM: 0.722) for post-suctioning assessment and care. The inter-rater ICC for overall performance was 0.752 (lower one-sided 95% CI: 0.602; SEM: 0.660). ICCs for intra-rater reliability ranged from 0.759 (lower one-sided 95% CI: 0.197; SEM 0.721) for infection control to 0.860 (lower one-sided 95% CI: 0.544; SEM: 0.550) for post-suctioning assessment and care. The intra-rater ICC for overall performance was 0.867 (lower one-sided 95% CI: 0.559; SEM: 0.483). Discussion: Evidence of moderate to good inter-rater and good intra-rater reliability was found; however, the results should be interpreted with caution given the wide Cis and relatively large SEMs. Improved assessor training and assessments of reliability using a larger sample size are recommended.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] The Inter-Rater and Intra-Rater Reliability of the Actual Aquatic Skills Test (AAST) for Assessing Young Children's Motor Competence in the Water
    Mertens, Lisa
    De Martelaer, Kristine
    Saeaekslahti, Arja
    D'Hondt, Eva
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (01)
  • [32] Tibial speed of sound in extremely preterm infants: inter-rater and intra-rater reliability
    Lopez, M. Romero
    Tibe, C.
    Naik, M.
    Yu-Carr, M.
    Bachim, A.
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2025, 369
  • [33] Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers
    Greene, Amanda
    Lasner, Andrea
    Deu, Rajwinder
    Oliphant, Seth
    Johnson, Kenneth
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (01) : 94 - 99
  • [34] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [35] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [36] Inter-Rater and Intra-Rater Reliability of the Bahasa Melayu Version of Rose Angina Questionnaire
    Hassan, N. B.
    Choudhury, S. R.
    Naing, L.
    Conroy, R. M.
    Rahman, A. R. A.
    ASIA-PACIFIC JOURNAL OF PUBLIC HEALTH, 2007, 19 (03) : 45 - 51
  • [37] An evaluation of the inter-rater and intra-rater reliability of OccuPro's functional capacity evalution
    Scheel, Carrie
    Mecham, Jim
    Zuccarello, Vic
    Mattes, Ryan
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2018, 60 (03): : 465 - 473
  • [38] INTER-RATER AND INTRA-RATER AGREEMENT OF THE REHABILITATION ACTIVITIES PROFILE
    JELLES, F
    VANBENNEKOM, CAM
    LANKHORST, GJ
    SIBBEL, CJP
    BOUTER, LM
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1995, 48 (03) : 407 - 416
  • [39] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796
  • [40] Inter-rater, intra-rater and inter-instrument reliability of an electrogoniometer to measure wrist range of motion
    da Silva Camassuti, Patricia Aparecida
    Marcolino, Alexandre Marcio
    Tamanini, Guilherme
    Barbosa, Rafael Inacio
    Barbosa, Amanda Matias
    Registro Fonseca, Marisa de Cassia
    HAND THERAPY, 2015, 20 (01) : 3 - 10