Apices of maxillary premolars observed by swept source optical coherence tomography

被引:0
|
作者
Ebihara, Arata [1 ]
Iino, Yoshiko [1 ]
Yoshioka, Toshihiko [1 ]
Hanada, Takahiro [1 ]
Sunakawa, Mitsuhiro [1 ]
Sumi, Yasunori [2 ]
Suda, Hideaki [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Pulp Biol & Endodont, Bunkyo Ku, Tokyo 1138549, Japan
[2] Natl Ctr Geriatr & Gerontol, Ctr Adv Med Dent & Oral Dis, Dept Adv Dent Res, Obu, Aichi 4748511, Japan
来源
LASERS IN DENTISTRY XXI | 2015年 / 9306卷
关键词
SS-OCT; Micro CT; dental operating microscope (DOM); 3D imaging; apicoectomy; endodontics; endodontic surgery; resected root surface; MICROSCOPE;
D O I
10.1117/12.2076924
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Apicoectomy is performed for the management of apical periodontitis when orthograde root canal treatment is not possible or is ineffective. Prior to the surgery, cone beam computed tomography (CBCT) examination is often performed to evaluate the lesion and the adjacent tissues. During the surgical procedure, the root apex is resected and the resected surface is usually observed under dental operating microscope (DOM). However, it is difficult to evaluate the details and the subsurface structure of the root using CBCT and DOM. A new diagnostic system, swept source optical coherence tomography (SS-OCT), has been developed to observe the subsurface anatomical structure. The aim of this study was to observe resected apical root canals of human maxillary premolars using SS-OCT and compare the findings with those observed using CBCT and DOM. Six extracted human maxillary premolars were used. After microfocus computed tomography (Micro CT; for gold standard) and CBCT scanning of the root, 1 mm of the apex was cut perpendicular to the long axis of the tooth. Each resected surface was treated with EDTA, irrigated with saline solution, and stained with methylene blue dye. The resected surface was observed with DOM and SS-OCT. This sequence was repeated three times. The number of root canals was counted and statistically evaluated. There was no significant difference in the accuracy of detecting root canals among CBCT, DOM and SS-OCT (p > 0.05, Wilcoxon test). Because SS-OCT can be used in real time during surgery, it would be a useful tool for observing resected apical root canals.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Swept Source Optical Coherence Tomography: a Review
    Yasin Alibhai A.
    Or C.
    Witkin A.J.
    Current Ophthalmology Reports, 2018, 6 (1) : 7 - 16
  • [2] Vitreous Changes in High Myopia Observed by Swept-Source Optical Coherence Tomography
    Itakura, Hirotaka
    Kishi, Shoji
    Li, Danjie
    Nitta, Keisuke
    Akiyama, Hideo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (03) : 1447 - 1452
  • [3] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [4] Evaluation of Root Canal Anatomy of Maxillary Premolars Using Swept-Source Optical Coherence Tomography in Comparison with Dental Operating Microscope and Cone Beam Computed Tomography
    Rashed, Bayan
    Iino, Yoshiko
    Komatsu, Kei
    Nishijo, Miki
    Hanada, Takahiro
    Ebihara, Arata
    Sunakawa, Mitsuhiro
    Sumi, Yasunori
    Okiji, Takashi
    PHOTOMEDICINE AND LASER SURGERY, 2018, 36 (09) : 487 - 492
  • [5] Detection of a Second Mesiobuccal Canal in Maxillary Molars by Swept-source Optical Coherence Tomography
    Iino, Yoshiko
    Ebihara, Arata
    Yoshioka, Toshihiko
    Kawamura, Jun
    Watanabe, Satoshi
    Hanada, Takahiro
    Nakano, Kiwako
    Sumi, Yasunori
    Suda, Hideaki
    JOURNAL OF ENDODONTICS, 2014, 40 (11) : 1865 - 1868
  • [6] Handheld swept source optical coherence tomography angiography
    Liu, Gangjun
    Yang, Jianlong
    Liu, Liang
    Campbell, J. Peter
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [7] Swept source optical coherence tomography in globe perforation
    Dubey, Devashish
    Shanmugam, Mahesh
    Ramanjulu, Rajesh
    Mishra, K. C. Divyansh
    Doshi, Bindiya
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (10) : 1697 - +
  • [8] MHz Swept Source Optical Coherence Tomography of the Choriocapillaris
    Schmoll, Tilman
    Niederleithner, Michael
    Britten, Anja
    Matten, Philipp
    Bello, Simon
    Kubach, Sophie
    Drexler, Wolfgang
    Leitgeb, Rainer
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (11)
  • [9] Fast Broadband Swept Source for Optical Coherence Tomography
    Cordes, A. H.
    Vilela de Faria, G.
    von der Weid, J. P.
    2009 SBMO/IEEE MTT-S INTERNATIONAL MICROWAVE AND OPTOELECTRONICS CONFERENCE (IMOC 2009), 2009, : 143 - 146
  • [10] Swept Source optical coherence tomography of choroidal nevi
    Michalewska, Zofia
    Michalewski, Janusz
    Nawrocki, Jerzy
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2016, 51 (04): : 271 - 276