Apices of maxillary premolars observed by swept source optical coherence tomography

被引:0
|
作者
Ebihara, Arata [1 ]
Iino, Yoshiko [1 ]
Yoshioka, Toshihiko [1 ]
Hanada, Takahiro [1 ]
Sunakawa, Mitsuhiro [1 ]
Sumi, Yasunori [2 ]
Suda, Hideaki [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Pulp Biol & Endodont, Bunkyo Ku, Tokyo 1138549, Japan
[2] Natl Ctr Geriatr & Gerontol, Ctr Adv Med Dent & Oral Dis, Dept Adv Dent Res, Obu, Aichi 4748511, Japan
来源
LASERS IN DENTISTRY XXI | 2015年 / 9306卷
关键词
SS-OCT; Micro CT; dental operating microscope (DOM); 3D imaging; apicoectomy; endodontics; endodontic surgery; resected root surface; MICROSCOPE;
D O I
10.1117/12.2076924
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Apicoectomy is performed for the management of apical periodontitis when orthograde root canal treatment is not possible or is ineffective. Prior to the surgery, cone beam computed tomography (CBCT) examination is often performed to evaluate the lesion and the adjacent tissues. During the surgical procedure, the root apex is resected and the resected surface is usually observed under dental operating microscope (DOM). However, it is difficult to evaluate the details and the subsurface structure of the root using CBCT and DOM. A new diagnostic system, swept source optical coherence tomography (SS-OCT), has been developed to observe the subsurface anatomical structure. The aim of this study was to observe resected apical root canals of human maxillary premolars using SS-OCT and compare the findings with those observed using CBCT and DOM. Six extracted human maxillary premolars were used. After microfocus computed tomography (Micro CT; for gold standard) and CBCT scanning of the root, 1 mm of the apex was cut perpendicular to the long axis of the tooth. Each resected surface was treated with EDTA, irrigated with saline solution, and stained with methylene blue dye. The resected surface was observed with DOM and SS-OCT. This sequence was repeated three times. The number of root canals was counted and statistically evaluated. There was no significant difference in the accuracy of detecting root canals among CBCT, DOM and SS-OCT (p > 0.05, Wilcoxon test). Because SS-OCT can be used in real time during surgery, it would be a useful tool for observing resected apical root canals.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Swept source optical coherence tomography based on scanning fiber probe
    Wu, Tong
    Ding, Zhihua
    Wang, Kai
    Xu, Lei
    Chen, Minghui
    Wang, Chuan
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (SUPPL.): : 37 - 41
  • [42] Assessing Embryo Development using Swept Source Optical Coherence Tomography
    Caujolle, S.
    Cernat, R.
    Silvestri, G.
    Marques, M. J.
    Bradu, A.
    Feuchter, T.
    Robinson, G.
    Griffin, D.
    Podoleanu, A.
    2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES, 2018, 10591
  • [43] Artifact in swept source optical coherence tomography due to silicone oil
    Singh, Sumit Randhir
    Chhablani, Jay
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (08) : 1184 - 1185
  • [44] Swept source optical coherence tomography of objects with arbitrary reflectivity profiles
    Mezgebo, Biniyam
    Nagib, Karim
    Fernando, Namal
    Kordi, Behzad
    Sherif, Sherif
    2ND CANTERBURY CONFERENCE ON OCT WITH EMPHASIS ON BROADBAND OPTICAL SOURCES, 2018, 10591
  • [45] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257
  • [46] Swept-source optical coherence tomography imaging of the retinochoroid and beyond
    Vira, Jayesh
    Marchese, Alessandro
    Singh, Rohan Bir
    Agarwal, Aniruddha
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (05) : 413 - 426
  • [47] Swept-source optical coherence tomography findings in peripheral drusen
    Kumar, Vinod
    Tewari, Ruchir
    Chandra, Parijat
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (12) : 930 - 931
  • [48] The Latest Updates in Swept-Source Optical Coherence Tomography Angiography
    Xia, Fan
    Hua, Rui
    DIAGNOSTICS, 2024, 14 (01)
  • [49] Multiband swept laser source for frequency domain optical coherence tomography
    Jiang, Junfeng
    Hui, Rongqing
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [50] MEMS scanner based swept source laser for optical coherence tomography
    Totsuka, Kouki
    Isamoto, Keiji
    Sakai, Tooru
    Morosawa, Atsushi
    Chong, Changho
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554