Comparison of Synthetic Computed Tomography Generation Methods, Incorporating Male and Female Anatomical Differences, for Magnetic Resonance Imaging-Only Definitive Pelvic Radiotherapy

被引:12
|
作者
O'Connor, Laura M. [1 ,2 ]
Choi, Jae H. [1 ,3 ]
Dowling, Jason A. [4 ]
Warren-Forward, Helen [2 ]
Martin, Jarad [1 ,5 ]
Greer, Peter B. [1 ,3 ]
机构
[1] Calvary Mater Hosp, Dept Radiat Oncol, Newcastle, NSW, Australia
[2] Univ Newcastle, Sch Hlth Sci, Callaghan, NSW, Australia
[3] Univ Newcastle, Sch Math & Phys Sci, Callaghan, NSW, Australia
[4] CSIRO, Australian E Hlth Res Ctr, Herston, Qld, Australia
[5] Univ Newcastle, Sch Med & Publ Hlth, Callaghan, NSW, Australia
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
关键词
MRI radiotherapy planning; image-guided radiotherapy; synthetic CT; computer-assisted radiotherapy planning; rectum neoplasms; cervix neoplasms; endometrium neoplasms; anal canal neoplasms; BEAM RADIATION-THERAPY; CT GENERATION; ELECTRON-DENSITY; MRI; FEASIBILITY;
D O I
10.3389/fonc.2022.822687
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeThere are several means of synthetic computed tomography (sCT) generation for magnetic resonance imaging (MRI)-only planning; however, much of the research omits large pelvic treatment regions and female anatomical specific methods. This research aimed to apply four of the most popular methods of sCT creation to facilitate MRI-only radiotherapy treatment planning for male and female anorectal and gynecological neoplasms. sCT methods were validated against conventional computed tomography (CT), with regard to Hounsfield unit (HU) estimation and plan dosimetry. Methods and MaterialsPaired MRI and CT scans of 40 patients were used for sCT generation and validation. Bulk density assignment, tissue class density assignment, hybrid atlas, and deep learning sCT generation methods were applied to all 40 patients. Dosimetric accuracy was assessed by dose difference at reference point, dose volume histogram (DVH) parameters, and 3D gamma dose comparison. HU estimation was assessed by mean error and mean absolute error in HU value between each sCT and CT. ResultsThe median percentage dose difference between the CT and sCT was <1.0% for all sCT methods. The deep learning method resulted in the lowest median percentage dose difference to CT at -0.03% (IQR 0.13, -0.31) and bulk density assignment resulted in the greatest difference at -0.73% (IQR -0.10, -1.01). The mean 3D gamma dose agreement at 3%/2 mm among all sCT methods was 99.8%. The highest agreement at 1%/1 mm was 97.3% for the deep learning method and the lowest was 93.6% for the bulk density method. Deep learning and hybrid atlas techniques gave the lowest difference to CT in mean error and mean absolute error in HU estimation. ConclusionsAll methods of sCT generation used in this study resulted in similarly high dosimetric agreement for MRI-only planning of male and female cancer pelvic regions. The choice of the sCT generation technique can be guided by department resources available and image guidance considerations, with minimal impact on dosimetric accuracy.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen
    Dal Bello, Riccardo
    Lapaeva, Mariia
    La Greca Saint-Esteven, Agustina
    Wallimann, Philipp
    Gunther, Manuel
    Konukoglu, Ender
    Andratschke, Nicolaus
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [22] Cone beam computed tomography guided treatment delivery and planning verification for magnetic resonance imaging only radiotherapy of the brain
    Edmund, Jens M.
    Andreasen, Daniel
    Mahmood, Faisal
    Van Leemput, Koen
    ACTA ONCOLOGICA, 2015, 54 (09) : 1496 - 1500
  • [23] Proton range uncertainty caused by synthetic computed tomography generated with deep learning from pelvic magnetic resonance imaging
    Tian, Liheng
    Luehr, Armin
    ACTA ONCOLOGICA, 2023, 62 (11) : 1461 - 1469
  • [24] Indeterminate Liver and Renal Lesions: Comparison of Computed Tomography and Magnetic Resonance Imaging in Providing a Definitive Diagnosis and Impact on Recommendations for Additional Imaging
    Margolis, Nathaniel E.
    Shaver, Christine M.
    Rosenkrantz, Andrew B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) : 882 - 886
  • [25] An Inter-observer Study to Determine Radiotherapy Planning Target Volumes for Recurrent Gynaecological Cancer Comparing Magnetic Resonance Imaging Only With Computed Tomography-Magnetic Resonance Imaging
    Bernstein, D.
    Taylor, A.
    Nill, S.
    Imseeh, G.
    Kothari, G.
    Llewelyn, M.
    De Paepe, K. N.
    Rockall, A.
    Shiarli, A-M
    Oelfke, U.
    CLINICAL ONCOLOGY, 2021, 33 (05) : 307 - 313
  • [26] Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy
    Noel, Camille E.
    Parikh, Parag J.
    Spencer, Christopher R.
    Green, Olga L.
    Hu, Yanle
    Mutic, Sasa
    Olsen, Jeffrey R.
    ACTA ONCOLOGICA, 2015, 54 (09) : 1474 - 1482
  • [27] Computed tomography image generation from magnetic resonance imaging using Wasserstein metric for MR-only radiation therapy
    Joseph, Jiffy
    Hemanth, Challa
    Pulinthanathu Narayanan, Pournami
    Pottekkattuvalappil Balakrishnan, Jayaraj
    Puzhakkal, Niyas
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2022, 32 (06) : 2080 - 2093
  • [28] Comparison of positron emission tomography/computed tomography and magnetic resonance imaging for posttherapy evaluation in patients with advanced cervical cancer receiving definitive concurrent chemoradiotherapy
    Tzu-Pei Su
    Gigin Lin
    Yu-Ting Huang
    Feng-Yuan Liu
    Chun-Chieh Wang
    Angel Chao
    Hung-Hsueh Chou
    Tzu-Chen Yen
    Chyong-Huey Lai
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 727 - 734
  • [29] Comparison of positron emission tomography/computed tomography and magnetic resonance imaging for posttherapy evaluation in patients with advanced cervical cancer receiving definitive concurrent chemoradiotherapy
    Su, Tzu-Pei
    Lin, Gigin
    Huang, Yu-Ting
    Liu, Feng-Yuan
    Wang, Chun-Chieh
    Chao, Angel
    Chou, Hung-Hsueh
    Yen, Tzu-Chen
    Lai, Chyong-Huey
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (05) : 727 - 734
  • [30] Applying a commercial atlas-based synthetic Computed Tomography algorithm to patients with hip prostheses for prostate Magnetic Resonance-only radiotherapy
    Wyatt, Jonathan
    McCallum, Hazel
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : 100 - 105