Does hypopharyngeal-esophageal multichannel intraluminal impedance-pH monitoring for the diagnosis of laryngopharyngeal reflux have to be 24 h?

被引:3
|
作者
Zhang, Jinhong [1 ,2 ]
Wang, Xiaoyu [2 ]
Wang, Jiasen [2 ]
Zhao, Jing [2 ]
Zhang, Chun [2 ]
Liu, Zhi [2 ]
Li, Jinrang [1 ,2 ]
机构
[1] South China Univ Technol, Sch Med, Dept Otolaryngol, Guangzhou 510006, Peoples R China
[2] PLA Gen Hosp Beijing, Dept Otolaryngol, Med Ctr 6, Beijing 100048, Peoples R China
关键词
LPR; Salivary pepsin; HEMII-pH; Combined diagnosis; PEPSIN; LARYNGEAL; RELIABILITY; VALIDITY; DISEASE;
D O I
10.1007/s00405-022-07554-w
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Purpose To investigate the diagnostic value of combined multi-timepoint salivary pepsin testing (MTPSPT) and hypopharyngeal-esophageal multichannel intraluminal impedance-pH monitoring (HEMII-pH) for laryngopharyngeal reflux (LPR) and whether an appropriate reduction in the duration of HEMII-pH would affect the accuracy of diagnosis of LPR. Methods Recruited patients were studied with both MTPSPT and HEMII-pH. The diagnosis of LPR was based on the occurrence of > 1 reflux event and/or positive results on any of the MTPSPT. The diagnostic value of combined diagnosis was studied through combining a breakdown of the 24-h HEMII-pH finding and the results of the MTPSPT. The diagnostic value was expressed in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Results Based on 24-h HEMII-pH and MTPSPT, the positive rate of LPR was 83.33% and 74.69%, respectively. According to the combined diagnosis, the positive rate of LPR was 90.74%. The sensitivity and specificity of the combined diagnosis both were 89.51% and 100%, when the HEMII-pH intervals were 7 a.m.-6 p.m. and 7 a.m.-7 p.m., respectively. However, when the monitoring time was extended to 8 p.m. and bedtime, the sensitivity, specificity, PPV and NPV of the combined diagnosis both were 100%. Conclusions The combination of MTPSPT and HEMII-pH increased the sensitivity and accuracy of diagnosis of LPR. For patients with positive MTPSPT results, the duration of HEMII-pH can be appropriately shortened to reduce patient sufferings.
引用
收藏
页码:5323 / 5329
页数:7
相关论文
共 50 条
  • [21] Esophageal combined multichannel intraluminal impedance-pH monitoring and its clinical value in the diagnosis of various types of gastroesophageal reflux disease
    Morozov, S.
    Kukushkina, M.
    Isakov, V.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 : 96 - 96
  • [22] 24-Hour Multichannel Intraluminal Impedance-pH in Proton Pump Inhibitor Nonresponders vs Responders in Patients With Laryngopharyngeal Reflux
    Kim, Su Il
    Jeong, Su Jin
    Kwon, Oh Eun
    Park, Jung Min
    Lee, Young Chan
    Eun, Young-Gyu
    Ko, Seong-Gyu
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2022, 166 (05) : 910 - 916
  • [23] Liquid Gastroesophageal Reflux Characterization by Investigating Multichannel Intraluminal Impedance-pH Monitoring Data
    Rasouli, A.
    Rabbani, H.
    Raisi, M.
    Soheilipour, M.
    Adibi, P.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4636 - 4639
  • [24] Reflux characteristics of 113 GERD patients with abnormal 24-h multichannel intraluminal impedance-pH tests
    Nian, Yuan-yuan
    Feng, Cheng
    Jing, Fu-chun
    Wang, Xue-qin
    Zhang, Jun
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2015, 16 (09): : 805 - 810
  • [25] The role of combined 24-h multichannel intraluminal impedance-pH monitoring in the evaluation of children with gastrointestinal symptoms suggesting gastro-esophageal reflux disease
    Hojsak, I.
    Ivkovic, L.
    Trbojevic, T.
    Pavic, I.
    Jadresin, O.
    Misak, Z.
    Kolacek, S.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2016, 28 (10): : 1488 - 1493
  • [26] Comparison of multichannel intraluminal impedance-pH monitoring and reflux scintigraphy in pediatric patients with suspected gastroesophageal reflux
    Kizilkan, Nuray Uslu
    Bozkurt, Murat Fani
    Temizel, Inci Nur Saltik
    Demir, Hulya
    Yuce, Aysel
    Caner, Biray
    Ozen, Hasan
    WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (43) : 9595 - 9603
  • [27] Reflux profile of Chinese gastroesophageal reflux disease patients with combined multichannel intraluminal impedance-pH monitoring
    Xiao, Ying L.
    Lin, Jin K.
    Cheung, Ting K.
    Wong, Nina Y. H.
    Hung, Ivan F. N.
    Wong, Benjamin C. Y.
    Peng, Sui
    Wang, An J.
    Chen, Min H.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 (06) : 1113 - 1118
  • [28] Diffuse Low Impedance on Multichannel Intraluminal Impedance-pH: Reflux, Dysmotility, or Barretts?
    Shin, Grace H.
    Sachdeva, Priyanka
    Parkman, Henry P.
    GASTROENTEROLOGY, 2013, 144 (05) : S790 - S790
  • [29] Esophageal Impedance-pH Monitoring and Pharyngeal pH Monitoring in the Diagnosis of Extraesophageal Reflux in Children
    Plocek, Anna
    Gebora-Kowalska, Beata
    Bialek, Jakub
    Fendler, Wojciech
    Toporowska-Kowalska, Ewa
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2019, 2019
  • [30] Comparison Between Manual and Automated Analyses in Multichannel Intraluminal Impedance: pH Monitoring for Laryngopharyngeal Reflux
    Kang, Hee Jin
    Park, Jung Min
    Choi, Soo Young
    Kim, Su Il
    Lee, Young Chan
    Eun, Young-Gyu
    Ko, Seong-Gyu
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2022, 166 (01) : 128 - 132