FASCAL 2: a new NIST facility for the calibration of the spectral irradiance of sources

被引:17
|
作者
Yoon, HW [1 ]
Proctor, JE [1 ]
Gibson, CE [1 ]
机构
[1] Natl Inst Stand & Technol, Opt Technol Div, Gaithersburg, MD 20899 USA
关键词
D O I
10.1088/0026-1394/40/1/308
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The facility for automated spectroradiometric calibrations (FASCAL) is the primary facility for calibration of spectral irradiance and spectral radiance at NIST and has been in continuous use since the early 1970s. Due to the increasing demands for spectroradiometric calibration, especially for supporting the monitoring of global environmental changes, a new facility, FASCAL 2, dedicated to calibrating spectral irradiance has been built. This facility will enable faster responses to calibration requests and, ultimately, result in lower uncertainties in the disseminated spectral irradiances. The FASCAL 2 facility is designed with the objective of achieving a signal-to-noise ratio exceeding 1000: 1 from 250 nm to 2500 nm in a bandwidth of 4 nm to 8 nm when measuring a 1000 W FEL lamp at a distance of 50 cm with a receiving aperture of 1 cm(2). The facility will also be capable of calibrating deuterium lamps from 200 nm to 400 rim. The facility has six independent source stations, with four of the stations dedicated to measurements with spectral irradiance lamps and two stations reserved for the realization of spectral irradiance scales and checking the accuracy of automated wavelength. After verifying that the calibrations of spectral irradiance performed in FASCAL and FASCAL 2 agree within their combined uncertainties, FASCAL 2 will become the primary NIST facility for calibration of spectral irradiance.
引用
收藏
页码:S30 / S34
页数:5
相关论文
共 50 条
  • [31] Preflight Spectral Radiance Infrared Calibration Facility
    Morozova, S. P.
    Katysheva, A. A.
    Panfilov, A. S.
    Krutikov, V. N.
    Lisyansky, B. E.
    Sapritsky, V. I.
    Parfentyev, N. A.
    Makolkin, E. V.
    Mitrofanov, B. D.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (6-7) : 1330 - 1340
  • [32] Preflight Spectral Radiance Infrared Calibration Facility
    S. P. Morozova
    A. A. Katysheva
    A. S. Panfilov
    V. N. Krutikov
    B. E. Lisyansky
    V. I. Sapritsky
    N. A. Parfentyev
    E. V. Makolkin
    B. D. Mitrofanov
    International Journal of Thermophysics, 2014, 35 : 1330 - 1340
  • [33] Absolute calibration of low-energy photon sources - The NIST approach
    Mitch, M.
    Seltzer, S.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S178 - S178
  • [34] Calibration of broadband ultraviolet detectors by measurement of spectral irradiance responsivity
    Envall, Jouni
    Karha, Petri
    Ikonen, Erkki
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (06):
  • [35] CALIBRATION OF INCANDESCENT LAMPS FOR SPECTRAL IRRADIANCE BY MEANS OF ABSOLUTE RADIOMETERS
    BOIVIN, LP
    APPLIED OPTICS, 1980, 19 (16): : 2771 - 2780
  • [36] NEW NML SCALE OF SPECTRAL IRRADIANCE
    WILKINSON, FJ
    METROLOGIA, 1975, 11 (03) : 105 - 110
  • [37] Upgradation of a spectral irradiance measurement facility at National Physical Laboratory, India
    Parag Sharma
    V. K. Jaiswal
    Ranjana Sudama
    H. C. Mehrotra
    MAPAN, 2010, 25 : 21 - 28
  • [38] Spectral irradiance calibration of space remote sensing spectral radiometer in range of UV and VUV
    Huang, Yu
    Wang, Shu-Rong
    Zhang, Zhen-Duo
    Lin, Guan-Yu
    Li, Fu-Tian
    Guangzi Xuebao/Acta Photonica Sinica, 2007, 36 (SUPPL.): : 187 - 191
  • [39] Upgradation of a spectral irradiance measurement facility at National Physical Laboratory, India
    Sharma, Parag
    Jaiswal, V. K.
    Sudama
    Mehrotra, Ranjana
    Kandpal, H. C.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2010, 25 (01): : 21 - 28
  • [40] NIST calibration heart-ening for new treatment
    不详
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (03): : 395 - 395