Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze-Fog Environment

被引:12
|
作者
Ren, Ang [1 ,2 ]
Liu, Hongshun [1 ,2 ]
Wei, Jianchun [1 ,2 ]
Li, Qingquan [1 ,2 ]
机构
[1] Shandong Univ, Dept Elect Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Prov Key Lab UHV Transmiss Technol & Equ, 17923 Jingshi Rd, Jinan 250061, Shandong, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 10期
关键词
haze-fog; natural contamination; surface flashover; silicone rubber; insulators; INSULATORS; AEROSOL; CHINA;
D O I
10.3390/en10101580
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC), direct current (DC) positive polar (+), and DC negative polar (-) power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3-, SO42-, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction point would be formed, which would seriously reduce the dielectric strength of room temperature vulcanized silicone rubber.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Experimental study on the contamination deposition characteristics of insulators in a fog-haze environment
    Zhang, Chuyan
    Hu, Junyi
    Li, Jianchao
    Liu, Dong
    Wang, Liming
    Lu, Ming
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (02) : 406 - 413
  • [42] SURFACE CHARACTERIZATION OF THE SILICONE RUBBER PROSTHESIS
    BARTLETT, SO
    PINEDA, LY
    MOORE, DJ
    JOURNAL OF PROSTHETIC DENTISTRY, 1971, 25 (01): : 69 - &
  • [43] Surface Wettability of the Contaminative Silicone Rubber
    Hu, Yangyu
    Yu, Xiang
    Wang, Guogang
    Lu, Ming
    ENVIRONMENTAL TECHNOLOGY AND RESOURCE UTILIZATION II, 2014, 675-677 : 31 - +
  • [44] Effect of Cyclic Loading on Surface Instability of Silicone Rubber under Compression
    Li, Zhonglin
    Zhou, Zhiheng
    Li, Ying
    Tang, Shan
    POLYMERS, 2017, 9 (04):
  • [45] Effect of superhydrophobicity on surface damage of silicone rubber under AC voltage
    Li, Yufeng
    Jin, Haiyun
    Nie, Shichao
    Tong, Cheng
    Gao, Naikui
    AIP ADVANCES, 2018, 8 (03)
  • [46] Investigation of contamination flashover voltage of a porcelain long rod insulator with silicone rubber coating on the trunks
    Gautam, Basanta Kumar
    Matsumura, Shigeki
    Matsushita, Shouta
    Hashimoto, Takuma
    Sakanishi, Kenji
    Matsuoka, Ryosuke
    ICPASM 2005: PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 AND 2, 2006, : 591 - +
  • [47] Surface modification of silicone rubber by CF4 radio frequency capacitively coupled plasma for improvement of flashover
    Wang, Chenxu
    Zhang, Guanjun
    Zhang, Bo
    Sun, Yuhao
    Peng, Yanan
    Yang, Xiong
    Chen, Sile
    Chen, Xingyu
    PLASMA SCIENCE & TECHNOLOGY, 2022, 24 (02)
  • [48] Surface modification of silicone rubber by CF4 radio frequency capacitively coupled plasma for improvement of flashover
    王晨旭
    张波
    陈思乐
    孙宇豪
    杨雄
    彭雅楠
    陈星宇
    张冠军
    Plasma Science and Technology, 2022, (02) : 109 - 118
  • [49] Effect of surface treatment of fillers on deterioration of silicone rubber housing materials in salt fog ageing test
    Marungsri, B
    Shinokubo, H
    Matsuoka, R
    Kumagai, S
    PROCEEDINGS OF THE 2005 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, VOLS, 1-3, 2005, : 556 - 559
  • [50] Effects of added silicone oils on the surface characteristics of silicone rubber
    Han, DH
    Park, HY
    Kang, DP
    Cho, HG
    Min, KE
    Takasu, K
    Kuroyagi, T
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (02) : 323 - 328