Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze-Fog Environment

被引:12
|
作者
Ren, Ang [1 ,2 ]
Liu, Hongshun [1 ,2 ]
Wei, Jianchun [1 ,2 ]
Li, Qingquan [1 ,2 ]
机构
[1] Shandong Univ, Dept Elect Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Prov Key Lab UHV Transmiss Technol & Equ, 17923 Jingshi Rd, Jinan 250061, Shandong, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 10期
关键词
haze-fog; natural contamination; surface flashover; silicone rubber; insulators; INSULATORS; AEROSOL; CHINA;
D O I
10.3390/en10101580
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC), direct current (DC) positive polar (+), and DC negative polar (-) power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3-, SO42-, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction point would be formed, which would seriously reduce the dielectric strength of room temperature vulcanized silicone rubber.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Surface discharge of silicone rubber under polluted conditions
    Chen, Y
    Liang, XD
    Fang, XD
    Guan, ZC
    Zhang, RY
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 275 - 278
  • [22] The Equivalent Dissolved Salt Deposit Density of Contamination on Surface of Silicone Rubber
    Cao, Bin
    Mei, Hongwei
    Wang, Liming
    Fu, Xiangyun
    Zhang, Zhifu
    Gao, He
    Lin, Xiangjun
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 676 - 679
  • [23] Surface resistance and hydrophobicity of HTV silicone rubber in the presence of salt-fog
    Zhang, H
    Hackam, R
    CONFERENCE RECORD OF THE 1998 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1998, : 355 - 359
  • [24] The effect of natural tropical climate to the surface properties of silicone rubber
    Sirait, KT
    Salama
    Suwarno
    Kaerner, HC
    1998 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS, PROCEEDINGS, 1998, : 453 - 456
  • [25] Hydrophobicity, Surface Charge and DC Flashover Characteristics of Direct-fluorinated RTV Silicone Rubber
    Du, B. X.
    Li, Z. L.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 934 - 940
  • [26] Understanding haze-fog pollution in central-eastern China under the background of sustainable development
    Tang, Dengli
    Li, Li
    Liu, Dongjun
    ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 865 - 869
  • [27] Simulation on Deposition Characteristics of Contamination Particles in Fog-Haze Environment
    Lv, Yukun
    Zhao, Weiping
    Song, Qingzhuang
    IEEE ACCESS, 2020, 8 : 26119 - 26128
  • [28] Evaluation of surface degradation of silicone rubber by continuous salt-fog aging test
    Adachi K.
    Miyake T.
    Sakoda T.
    IEEJ Transactions on Fundamentals and Materials, 2021, 141 (10) : 590 - 596
  • [29] The surface hydrophobicity of silicone rubber under the influence of corona treatment
    Liang, XD
    Gao, Y
    Zhang, J
    Okekearu, CW
    Warren, L
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 279 - 282
  • [30] Surface degradation of silicone rubber under accelerated aging condition
    Han, SI
    Yoon, JY
    Park, KS
    Han, SO
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 439 - 443