Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze-Fog Environment

被引:12
|
作者
Ren, Ang [1 ,2 ]
Liu, Hongshun [1 ,2 ]
Wei, Jianchun [1 ,2 ]
Li, Qingquan [1 ,2 ]
机构
[1] Shandong Univ, Dept Elect Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Prov Key Lab UHV Transmiss Technol & Equ, 17923 Jingshi Rd, Jinan 250061, Shandong, Peoples R China
来源
ENERGIES | 2017年 / 10卷 / 10期
关键词
haze-fog; natural contamination; surface flashover; silicone rubber; insulators; INSULATORS; AEROSOL; CHINA;
D O I
10.3390/en10101580
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based on four consecutive years of insulator contamination accumulation and atmospheric sampling in haze-fog environment, the contamination configuration appropriate for RTV-coated surface discharge test under simulation environment of haze-fog was put forward. ANSYS Maxwell was used to analyze the influence of room temperature vulcanized silicone rubber surface attachments on electric field distribution. The changes of droplet on the polluted room temperature vulcanized silicone rubber surface and the corresponding surface flashover voltage under alternating current (AC), direct current (DC) positive polar (+), and DC negative polar (-) power source were recorded by a high speed camera. The results are as follows: The main ion components from haze-fog atmospheric particles are NO3-, SO42-, NH4+, and Ca2+. In haze-fog environment, both the equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD) of insulators are higher than that under general environment. The amount of large particles on the AC transmission line is greater than that of the DC transmission line. The influence of DC polarity power source on the distribution of contamination particle size is not significant. After the deposition of haze-fog, the local conductivity of the room temperature vulcanized silicone rubber surface increased, which caused the flashover voltage reduce. Discharge is liable to occur at the triple junction point of droplet, air, and room temperature vulcanized silicone rubber surface. After the deformation or movement of droplets, a new triple junction point would be formed, which would seriously reduce the dielectric strength of room temperature vulcanized silicone rubber.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] AC flashover characteristics of insulators under haze-fog environment
    Guo, Yujun
    Jiang, Xingliang
    Liu, Yang
    Meng, Zhigao
    Li, Zhenyu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (14) : 3563 - 3569
  • [2] Contamination and AC Pollution Flashover Characteristics of Insulators Under Fog-Haze Environment
    Sun Youfei
    Tu Youping
    Wang Cong
    Wang Shaohe
    Cheng Yangchun
    Peng Qingjun
    Chen Xianfu
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 596 - 599
  • [3] Flashover Characteristics of Silicone Rubber Surface Influenced by Surface Charge
    Tanaka, H.
    Kawashima, T.
    Murakami, Y.
    Nagao, M.
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 836 - 839
  • [4] Prediction of Flashover of Silicone Rubber Insulator under Different Contaminated Surface Conditions
    Patel, Krishna
    Parekh, B. R.
    2013 IEEE 1ST INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2013, : 358 - 361
  • [5] Flashover characteristics of a droplet impacting the silicone rubber surface
    Li, Zong
    Wang, Naixiao
    Dong, Kai
    Mu, Lei
    Cao, Bin
    Wang, Liming
    AIP ADVANCES, 2023, 13 (01)
  • [6] Effect of surface roughness on flashover characteristics of silicone rubber
    Zhao, Yushun
    Xiang, Yitong
    Gu, Shanqiang
    Du, Bin
    Dong, Bingbing
    Xiang, Nianwen
    Xu, Heng
    JOURNAL OF ELECTROSTATICS, 2019, 99 : 41 - 48
  • [7] Numerical simulation of diurnally varying thermal environment in a street canyon under haze-fog conditions
    Tan, Zijing
    Dong, Jingliang
    Xiao, Yimin
    Tu, Jiyuan
    ATMOSPHERIC ENVIRONMENT, 2015, 119 : 95 - 106
  • [8] Experimental Research of Influence of Condensation on Flashover Characteristics of Silicone Rubber Surface
    Liu X.
    Hu Y.
    Li Y.
    Sun W.
    Zheng L.
    Dianwang Jishu/Power System Technology, 2019, 43 (08): : 3047 - 3054
  • [9] Influence of fog parameters on the surface resistance of HTV silicone rubber
    Zhang, H
    Hackam, R
    1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, : 43 - 47
  • [10] Effect of fog-haze on the hydrophobicity of Silicone Rubber in winter
    Wang, Jianhui
    Zhao, Yueju
    Teng, Jilin
    Miao, Wenhua
    Wang, Guogang
    Sun, Mingjun
    PROCEEDINGS OF THE 2016 7TH INTERNATIONAL CONFERENCE ON MECHATRONICS, CONTROL AND MATERIALS (ICMCM 2016), 2016, 104 : 457 - 462