The protection of artistic assets through the base isolation of historical buildings: a novel uplifting technology

被引:19
|
作者
Lignola, Gian Piero [1 ]
Di Sarno, Luigi [2 ]
Di Ludovico, Marco [1 ]
Prota, Andrea [1 ]
机构
[1] Univ Naples Federico II, Dept Struct Engn & Architecture, Via Claudio 21, I-80125 Naples, Italy
[2] Univ Sannio, Dept Engn, Piazza Roma 21, I-82100 Benevento, Italy
关键词
Earthquake damage; Historical buildings; Artistic assets; Base isolators; Seismic retrofit; Uplift; SEISMIC ISOLATION; MASONRY WALLS; RETROFIT; PERFORMANCE; BEHAVIOR;
D O I
10.1617/s11527-015-0785-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present paper focuses on a novel advanced procedure for the installation of base isolation system (BIS) in historical buildings. The performance objectives of such critical structures and contents are first assessed to set the ground for the reliable evaluation of the response under earthquake ground motions. A number of controversial steps in the evaluation of the seismic demand and possible performance objectives associated to different aspects for a cultural heritage asset are identified and possible solutions proposed. It is shown that BIS is a cost-effective and efficient method that can be employed to protect adequately historical structures and artistic assets. Notwithstanding, the installation of isolation devices in historical structures is not an easy task. A novel advanced procedure based on the construction of two reinforced concrete foundation mats at the base of the existing structure to uplift the sample buildings (e.g. churches, museums, palaces, etc.) is illustrated in the paper. Hydraulic jacks are located along the bearing walls and tend to be as less intrusive as possible. A case study is also investigated both experimentally and numerically; the sample structure consists of a full-scale traditional masonry residential building. Refined yet versatile finite element (FE) models of the sample structures have been implemented and are used to determine the stresses within the foundation mat and superstructure. The FE models were calibrated on in-situ measurements for both structures. Such numerical models were also utilized to perform parametric analyses.
引用
收藏
页码:4247 / 4263
页数:17
相关论文
共 25 条
  • [21] Seismical protection properties of high damping rubber bearing and lead rubber bearing base isolation systems for multi-storey RC buildings
    Cancellara, Donato
    De Angelis, Fabio
    APPLIED MECHANICS AND INDUSTRIAL TECHNOLOGIES, 2012, 234 : 90 - 95
  • [22] Seismic Protection of the Goddess of Morgantina Statue Through an Innovative Base-Isolation Device: Validation by Shake-Table Tests
    Alberti, Elena
    Ausenda, Giovanni
    Castino, Maria Chiara
    Lo Iacono, Francesco
    Navarra, Giacomo
    SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 717 - 725
  • [23] A novel method of searching appropriate ranges of base isolation design parameters through entropy-based classification
    Huang, Pei Chiung
    Wan, Shiuan
    Yen, Jia Yih
    STRUCTURAL CONTROL & HEALTH MONITORING, 2009, 16 (04): : 385 - 405
  • [24] Performance evaluation of eco-friendly scrap tyre base isolation technology in distinct construction quality RC framed buildings located in seismic risk zone
    Raj, J. Cici Jennifer
    Kumar, M. Vinod
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [25] Novel input ESD protection circuit with substrate-triggering technique in a 0.25-μm shallow-trench-isolation CMOS technology
    Ker, MD
    Chen, TY
    Wu, CY
    Tang, H
    Su, KC
    Sun, SW
    ISCAS '98 - PROCEEDINGS OF THE 1998 INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-6, 1998, : A212 - A215