In Vivo Stability of Hydroxyapatite Nanoparticles Coated on Titanium Implant Surfaces

被引:1
|
作者
Wennerberg, Ann [1 ,2 ]
Jimbo, Ryo [1 ,2 ]
Allard, Stefan [3 ]
Skarnemark, Gunnar [3 ]
Andersson, Martin [3 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, Malmo, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Biomat, Gothenburg, Sweden
[3] Chalmers, Dept Chem & Biol Engn, S-41296 Gothenburg, Sweden
基金
瑞典研究理事会;
关键词
implant; in vivo; nanocoat instability; CALCIUM-PHOSPHATE; OSTEOBLAST ADHESION; ENDOSSEOUS IMPLANTS; BONE-FORMATION; NANO; OSSEOINTEGRATION; CELLS; DOGS; RAT;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Nanotechnology has been employed in attempts to enhance bone incorporation of dental implants. Often, nanoparticles are applied to the implant surface as particle coatings. However, the same properties that may increase the functionality may also lead to undiscovered negative effects, such as instability of the nanocoating. The aim of this study was to investigate the stability/instability of the nanoparticles using a radiolabeling technique. Materials and Methods: Twenty threaded and turned titanium microimplants were inserted in 10 rats. All 20 implants were coated with nanometer-sized hydroxyapatite (HA) particles. In order to trace the HA nanoparticles, the particles for 16 implants were labeled with calcium 45 ((45)Ca). After 1, 2, 4, and 8 weeks, the implants and surrounding bone were retrieved and analyzed using autoradiography with respect to particle migration from the implant surface. Samples from the brain, liver, thymus, kidney, and blood, as well as wooden shavings from the rats' cages, were also retrieved and analyzed using liquid scintillation counting. Results: The radioactivity representing the localization of 45Ca decreased over time from the vicinity of the implant. The amounts of 45Ca found in the blood and in the rats' excretions decreased with time and corresponded well to each other. After 8 weeks, the only trace of 45Ca was found in the liver. Conclusion: The results indicated that released particles leave the body through the natural cleaning system, and the probability that the nanocoating will assemble in vital organs and thus become a potential biologic risk factor is unlikely. Int J Oral Maxillofac Implants 2011;26:1161-1166
引用
收藏
页码:1161 / 1166
页数:6
相关论文
共 50 条
  • [41] Enhanced osteoporotic effect of silicon carbide nanoparticles combine with nano-hydroxyapatite coated anodized titanium implant on healthy bone regeneration in femoral fracture
    Li, Tao
    Li, Xing-Long
    Hu, Shi-Xiang
    Wu, Jing
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2019, 197
  • [42] The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation
    Duan, Yonghong
    Zhu, Shu
    Guo, Fei
    Zhu, Jinyu
    Li, Mao
    Ma, Jie
    Zhu, Qingsheng
    ARCHIVES OF MEDICAL SCIENCE, 2012, 8 (02) : 199 - 208
  • [43] Fatigue failure of titanium biologically coated by hydroxyapatite
    Xu, KW
    Li, H
    Lu, J
    FATIGUE '99: PROCEEDINGS OF THE SEVENTH INTERNATIONAL FATIGUE CONGRESS, VOLS 1-4, 1999, : 1921 - 1926
  • [44] In Situ In Vivo radiolabeling of polymer-coated hydroxyapatite nanoparticles to track their biodistribution in mice
    Lobaz, Volodymyr
    Konefal, Rafal
    Panek, Jiri
    Vlk, Martin
    Kozempel, Jan
    Petrik, Milos
    Novy, Zbynek
    Gurska, Sona
    Znojek, Pawel
    Stepanek, Petr
    Hruby, Martin
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2019, 179 : 143 - 152
  • [45] In vivo comparison of the osseointegration of vacuum plasma sprayed titanium- and hydroxyapatite-coated implants
    Aebli, N
    Krebs, J
    Stich, H
    Schawalder, P
    Walton, M
    Schwenke, D
    Gruner, H
    Gasser, B
    Theis, JC
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (02): : 356 - 363
  • [46] Stability of hydroxyapatite coating of different crystallinities on a titanium alloy implant material after cyclic fatigue
    Ashroff, S
    Napper, SA
    Hale, PN
    Siriwardane, U
    Mukherjee, DP
    PROCEEDINGS OF THE 1996 FIFTEENTH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE, 1996, : 14 - 17
  • [47] Hydroxyapatite formation on bioactive glass coated titanium
    Kim, CY
    Kwon, SM
    BIOCERAMICS, VOL 10, 1997, : 37 - 40
  • [48] Hydroxyapatite formation on calcium phosphate coated titanium
    Sato, Mitsutaka
    Tu, Rong
    Goto, Takashi
    Ueda, Kyosuke
    Narushima, Takayuki
    PRICM 6: SIXTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-3, 2007, 561-565 : 1513 - +
  • [49] Osteoinductive hydroxyapatite-coated titanium implants
    Ripamonti, Ugo
    Roden, Laura C.
    Renton, Louise F.
    BIOMATERIALS, 2012, 33 (15) : 3813 - 3823
  • [50] A histomorphological study of tendon reconstruction to a hydroxyapatite-coated implant: regeneration of a neo-enthesis in vivo
    Pendegrass, CJ
    Oddy, MJ
    Cannon, SR
    Briggs, T
    Goodship, AE
    Blunn, GW
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (06) : 1316 - 1324